DCM1500S User Guide
2
www.megger.com
This manual supersedes all previous issues of this manual. Please ensure that you are
using the most recent issue of this document. Destroy any copies that are of an older
issue.
Declaration of Conformity
Hereby, Megger Instruments Limited declares that radio equipment manufactured by
Megger Instruments Limited described in this user guide is in compliance with Directive
2014/53/EU. Other equipment manufactured by Megger Instruments Limited described
in this user guide is in compliance with Directives 2014/30/EU and 2014/35/EU where they
apply.
The full text of Megger Instruments EU declarations of conformity are available at the
following internet address
megger.com/company/about-us/eu-dofc
www.megger.comDCM1500S User Guide
3
Safety Information
G
Understand and follow the operating instructions carefully.
WARNING
G
Identify hazardous conditions and actions that could cause BODILY HARM or DEATH
When using test leads or probes, keep your fingers behind the finger guards.
Personal protective equipment should be used if there are ACCESSIBLE
HAZARDOUS LIVE PARTS in the installation where measurement is to be carried
out.
Remove test leads from meter before opening the battery door or meter case.
Use the meter only as specified in this manual; otherwise, the protection provided
by the meter may be impaired.
Always use the proper input terminals, switch position, and range for
measurements.
Verify the meters operation by measuring a known voltage. If in doubt, have the
meter calibrated.
Do not apply more than the rated voltage, as marked on the meter, between
terminals or between any terminal and earth.
Use caution with voltages above 30 V AC rms, 42 V AC peak, or 60 V DC. These
voltages pose a shock hazard.
To avoid false readings that can lead to electric shock and injury, replace the
battery as soon as the low battery indicator blinks.
Disconnect circuit power and discharge all high-voltage capacitors before testing
resistance, continuity, diodes, or capacitance.
Do not use the meter around explosive gas or vapour.
To reduce the risk of fire or electric shock do not expose this product to rain or
moisture.
Probe assemblies to be used for MAINS measurements shall be RATED as
appropriate for MEASUREMENT CATEGORY III or IV according to EN 61010031 and shall have a voltage RATING of at least the voltage of the circuit to be
measured.
DCM1500S User Guide
4
www.megger.com
Safety Information
G
■ DO NOT USE the test leads if the internal white insulation layer is exposed.
■ DO NOT USE the test leads above maximum ratings of CAT Environment or
voltage and current that are indicated on the probe and probe tip guard.
■ Do not apply a current with a frequency that is higher than the frequency
response range specied in the Electrical Specications section.
■ Do not apply or remove the clamp or test leads on or around uninsulated
hazardous live conductors where a potential to cause electric shock, electrical
burns or arc ash exists.
CAUTION
G
Disconnect the test leads from the test points before changing the position of the
function rotary switch.
Never connect a source of voltage with the function rotary switch in Ω,
position.
Do not expose the meter to extremes of temperature or high humidity.
and
www.megger.comDCM1500S User Guide
5
Symbols as marked on the Meter and Instruction manual
Risk of electric shock
See instruction manual
DC measurement
AC measurement
Both direct and alternating current
Equipment protected by double or reinforced insulation
Battery
Earth
Conforms to EU directives
Conforms to UKCA directives
Application around and removal from hazardous live conductors
Do not discard this product or throw away
Bluetooth®
CATIV
Measurement category IV: Equipment connected between the origin of the low-voltage
mains supply outside the building and the consumer unit.
CATIII
Measurement category III: Equipment connected between the consumer unit and the
electrical outlets.
CATII
Measurement category II: Equipment connected between the electrical outlets and the
user’s equipment.
Unsafe Voltage
G
To alert you to the presence of a potentially hazardous voltage, when the tester
detects a voltage ≥30 V or a voltage overload (OL) in V, mV, PV. The V symbol is
displayed.
DCM1500S User Guide
6
www.megger.com
Features
6000 Count LCD display
Backlight
VoltSeek (Non-Contact Voltage Detection)
True RMS reading on AC
Data logger (up to 4000 sample values)
Manual save mode
Bluetooth® communication
Torch turns on when clamp jaws open
1500 A AC/DC current measurement
DC voltage measurement up to 2000 V using the PVHV lead set
AV voltage measurement up to 1500 V using the PVHV lead set
Upon removing your new Solar/PV Clamp Meter from its packing, you should have the
following items:
Megger DCM1500S Solar/PV Clamp Meter
Test lead set (one black, one red)
Test probes (one black, one red)
Crocodile clips (one black, one red)
TP100 Temperature probe
Megger PVHV1 Lead set (4mm plugs)
Megger PVHV2 Lead set (MC4 PV plugs)
User Manual
Carry case
Batteries
DCM1500S User Guide
8
www.megger.com
The Meter Description
Function Button
1 JAW
2 VoltSeek LED
3 Push button
4 Trigger
5 Rotary switch to turn the instrument On / Off and select a function
6 6,000 count LCD display
7 Positive input terminal
8 Common (earth reference) input terminal
www.megger.comDCM1500S User Guide
9
Making Basic Measurements
Preparation and Caution Before Measurement
Observe the rules of G Warnings and G Cautions.
G
CAUTION
G
When connecting the test leads to the DUT (Device Under Test) connect the common test
lead before connecting the live test lead. When removing the test leads remove the live
test lead before removing the common test lead.
Measuring Voltage
Turn the switch to select the measuring function.
DCM1500S User Guide
10
www.megger.com
Measuring PV Voltage
PV String
Turn the switch and press the Function button to select AC/DC mode
CAUTION
G
This function is only available with the dedicated PVHV test lead sets.
The PVHV test leads are designed for use in environments that are not directly
connected to the mains. Always select correct AC/DC mode to perform any high voltage
measurement.
The meter will flash this symbol
voltage is different and/or dangerous.
and the correct mode symbol (AC/DC) if the input
F
www.megger.comDCM1500S User Guide
11
Measuring Current
CAT IV 600 V
G
CAT III 1000 V
Fixed barrier hand guard
Do not hold the meter
G
across the xed barrier
Turn the switch and press the Function button to select AC/DC/Hz mode.
Note: The torch will turn on when the jaw is opened.
DCM1500S User Guide
12
www.megger.com