The AVO210 is a general purpose multimeter suitable for
electricians, heating engineers and alarm technicians. The
additional features make the instrument useful for a wide range of
applications.
The instrument offers AC and DC voltage and current
measurements as well as resistance, frequency and capacitance
ranges.
The AVO210 has simplified functions that avoid continuous
reference to the user guide.
The testleads included with the AVO210 have GS38 compliant
shrouded tips.
Auto-ranging
When first selected, all functions are auto-ranging. A range button
on the AVO210 allows multiple manual range selection on each
function.
Minimum / Maximum measurements
The instrument has a MIN MAX function that allows the user to
switch between minimum and maximum measurements. The display
does not have to be continually monitored to capture a momentary
increase or fall in readings.
Data Hold
This function allows a displayed result to be frozen which avoids
having to remember a measurement value. The hold function can
be nested within the MIN MAX feature which stops the AVO210
continuously updating the minimum and maximum values.
Voltage measurements
Both AC and DC voltage measurements up to 750 V and 1000 V
respectively are possible with the AVO210.
Current measurements
A separate fused terminal is provided for current measurements up
to 10 A for both AC and DC.
Continuity / diode testing
The continuity function features a buzzer and provides the user
both optical and audible indication of identifying and confirming
continuity between two points. This function also allows forward
and reverse bias testing of diode and semiconductor junctions.
Voltsense function
The AVO210 has a built in non-contact voltage sensor fitted in the
top of the instrument that is activated by the Voltsense button.
Resistance, capacitance and frequency
Resistance can be measured directly on the ohms range from 0 to
20 MΩ with capacitance measurements from 0 to 2.000 mF. In
addition, frequency measurements from 0 to 20 MHz are possible.
Battery indicator“<” is displayed when the batteries voltage drops below operating voltage
Auto power downApprox 10 minutes
Operating ambientNon-condensing ≤10 °C, 11 °C ~ 30 °C (≤80% R.H) 31°C ~ 40 °C (≤75% R.H), 41 °C ~
50 °C (≤45% R.H)
Storage temperature range
and humidity
Temperature co-efficient0.15 x (Spec. Accy.) / °C, < 18 °C or > 28 °C
Sample rateSamples 2 times per second nominal
Maximum altitude6561.7 ft (2000 m)
Safety
Complies with EN61010-1, UL61010-1, IEC 61010-1,
V/Ω CAT III 600 V, CATII 1000 V
A CAT III 500 V
Pollution degree2
Power supply1.5 V x 2 LR03 or AAA size
Battery lifeAlkaline 250 hours
Dimensions74 mm x 156 mm x 44 mm
Weight320 g
ELECTRICAL
Accuracy is ± (% reading + number of digits) at 23°C ± 5°C < 80%RH.
AC/DC volts
Range AC Accuracy
200.0 mV Unspecified
2.000 V * ±(1.5%+5 dgts) 50 Hz ~ 300 Hz
20.00 V ~ 200.0 V * ±(1.5%+5 dgts) 50 Hz ~ 500 Hz *
750 V AC / 1000 V DC ±(1.5%+5 dgts) 50 Hz ~ 500 Hz *
-20 °C to 60 °C, 0 to 80% R.H. when battery removed from meter
AVO210
Digital multimeter
DC Accuracy : ±(0.5% + 2 dgts)
Over voltage protection : 1000 V DC or 750 V AC rms.
Input Impedance : 10 MΩ // less than 100 pF.
* CMRR / NMRR : (Common Mode Rejection Ratio)
(Normal Mode Rejection Ratio)
VAC : CMRR > 60 dB at DC, 50 Hz / 60 Hz
VDC : CMRR > 100 dB at DC, 50 Hz / 60 Hz
NMRR > 50 dB at DC, 50 Hz / 60 Hz
AC conversion type
Average sensing rms indication.
AC conversions are ac-coupled, true rms responding, calibrated to the sine wave input.
* The minimum LCD reading is 1400 count in Auto Ranging Mode.
Crest Factor : C.F. = Peak / Rms
+ 1.5% addition error for C.F. from 1.4 to 3
+ 3% addition error for C.F. from 3 to 4
DC/AC current
Range DC Accuracy AC Accuracy Voltage Burden
2.000 A ±(1.0% + 3 dgts) ±(1.5% + 5 dgts) 2 V max
10.00 A ** ±(1.0% + 3 dgts) 50 Hz ~ 500 Hz* 2 V max
2
Overload protection
A input: 10 A (500 V) fast blow fuse
* AC Conversion Type : Conversion type and additional specification are same as DC/AC voltage.
** Ampere Testing Duty Ratio Table
Ampere Testing Time Rest Time
10 A 1 min 10 min
9 A 2 min 10 min
8 A 3 min 10 min
7 A 4 min 10 min
6 A 5 min 10 min
5 A Continually N/A
Resistance measurements
Range Accuracy Voltage Burden
200.0 ~ 200.0 KΩ ** ±(0.7% + 3 dgts) 2 V max
2.000 MΩ ** ±(1.0% + 3 dgts) 2 V max
20.00 MΩ * ±(1.5% + 3 dgts) 2 V max
* <100 dgt rolling.
* * The minimum LCD reading is 1400 count in Auto Ranging Mode.
Archcliffe Road Dover
CT17 9EN England
T +44 (0) 1304 502101
F +44 (0) 1304 207342
UKsales@megger.com
UNITED STATES
4271 Bronze Way
Dallas TX 75237-1019 USA
T 800 723 2861 (USA only)
T +1 214 333 3201
F +1 214 331 7399
USsales@megger.com
OTHER TECHNICAL SALES OFFICES
Valley Forge USA, College Station USA,
Sydney AUSTRALIA, Danderyd SWEDEN,
Ontario CANADA, Trappes FRANCE,
Oberursel GERMANY, Aargau SWITZERLAND,
Kingdom of BAHRAIN, Mumbai INDIA,
Johannesburg SOUTH AFRICA, Chonburi THAILAND
3
CERTIFICATION ISO
Registered to ISO 9001:2008 Cert. no. Q 09290
Registered to ISO 14001-2004 Cert. no. EMS 61597
AVO210_DS_en_V01
www.megger.com
Megger is a registered trademark
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.