Tool and Appliance Tester
■
Complete UL and ANSI testing in less than
one minute
■
Safeguards tools and appliances against
shock hazard
■
Reduces downtime and protects against
injury and liability
■
Maintains compliance with OSHA
regulations
Tool and Appliance Tester
DESCRIPTION
The Tool and Appliance Tester combines, in one portable
instrument, the three most frequently specified electrical
safety tests for tools and appliances. In conformance to UL
and ANSI test requirements, the instrument performs test
of ground continuity, leakage current, and electrical
insulation. It also checks the nameplate current rating of
the device.
APPLICATIONS
Poorly maintained electrical tools can become a safety
hazard and cause injury to personnel. Testing electrical
tools on a regular basis is not only safe practice against
costly repairs, but may even reduce liability. Applications
for this handy instrument include in-plant OSHA safety
surveys and production line, tool r
safety checks.
Ground Continuity Check
o check the integrity of the ground circuit between tool
T
and plug, the Tool and Appliance Tester applies a 25ampere test curr
circuit resistance exceeds the 0.10-ohm failure threshold, a
safety interlock prevents further testing. A bypass switch is
provided to allow testing of two-wire and double-insulated
devices.
ent to the ground circuit. If the ground
oom, and r
epair shop
Leakage Test
This test measures the current that would result from the
ground conductor being accidentally severed; that is the
current to which the operator would be subjected if
providing a path to ground at normal line voltage. A
switch is provided to select testing at normal or reverse
polarity. Measurements from 0 to 10 mA are indicated on a
large, 3.5-in. (89 mm) analog meter with sensitivity greater
than 0.01 mA. To ensure the accuracy of the meter, a
calibration check can be initiated at the push of a button.
Insulation Br
This test measur
voltage to detect weak spots in the insulation that may
cause failure in the future. Test voltage up to 3000 volts ac
may be applied, with the leakage current trip level
adjustable fr
knob. V
insulation failure.
Operational Check
The Tool and Appliance Tester also provides an operation
check to verify the nameplate current rating of the tool
and to deter
Measurements up to 15 amperes are indicated.
eakdown (High-Pot) Test
ent through insulation at high
es curr
om 0.3 to 12 mA by a front-panel contr
isual and audible alarms alert the operation to
mine if maintenance is required.
ol
FEATURES AND BENEFITS
■
ull conformance to latest UL and ANSI test
F
requirements.
■
eter reading — not just “good/bad” indications.
M
■
est procedures color-coded in sequence on front panel
T
for ease of use.
■
round check bypass switch permits testing of two-wire
G
or double-insulated devices.
■
Removable lid with metal tray holds device under test.
■
Heavy-duty case with carrying strap.
■
Front-panel NEMA 5-15 output receptacle, with adapters
available to convert to a 20-ampere plug or twist lock up
to 30-amperes.
SPECIFICATIONS
Input Power Source
120 V ac ±10%, 60 Hz, 15 A
Ground Check
Failure Threshold: 0.10 Ω
Maximum Test Voltage: 3 V, 60 Hz
Maximum Test Current: 25 A
Leakage Test
Indicates from 0 to 10 mA ac on a 3.5-in. (89-mm) analog scale
with 0.01-mA sensitivity
Test Voltage: 120 V ac, 60 Hz
Tool and Appliance Tester
nsulation Breakdown Test
I
Test Voltage: 0 to 3000 V ac, continuously adjustable. Applied
voltage indicated on a 3.5-in (89-mm) analog scale.
Maximum Short-circuit Current: 12.6 mA
Leakage Current Trip: Adjustable from 0.3 to 12 mA
Failure Indication: Audible and visual alarms
Operational Test
Indicates from 0 to 15 A ac on a 3.5-in
(89-mm) analog scale
Test Voltage: 120 V ac, 60 Hz
Environmental
Operating Temperature Range
50 to 104º F (10 to 40º C)
Storage Temperature Range
-22 to +131º F (-30 to +55º C)
Humidity
5 to 95% RH
Dimensions
10 H x 13.5 W x 10 D in.
(254 H x 343 W x 254 D mm)
Weight
28 lb (12.7 kg)
ORDERING INFORMATION
Item (Qty) Cat. No.
Tool and Appliance Tester 235303
Included Accessories
High-voltage lead
Ground cable
Instruction manual
Optional Accessories
Adapters to convert ouput receptable for use with
twist-lock and 20-ampere plugs
NEMA L5-15R twist lock 235300-1
NEMA L5-20R twist lock
NEMA L-20 R, 20 A
NEMTA L-30R twist lock 235300-4
UK
Archcliffe Road, Dover
CT17 9EN England
T (0) 1 304 502101
F (0) 1 304 207342
UKsales@megger.com
UNITED STATES
4271 Bronze Way
Dallas, TX 75237-1019 USA
T 1 800 723 2861 (USA only)
T 1 214 333 3201
F 1 214 331 7399
USsales@megger.com
235300-2
235300-3
OTHER TECHNICAL SALES OFFICES
Norristown USA, Sydney AUSTRALIA,
onto CANADA, T
or
T
Kingdom of BAHRAIN, Mumbai INDIA,
Johannesburg SOUTH AFRICA and
Conjure, THAILAND
rappes, FRANCE,
ISO STATEMENT
Registered to ISO 9001:2001 Cert. no. 10006.01
TOOL_APPLIANCE_DS_En_V02
.com
.megger
www
Megger is a r
egister
ed trademark