Safety Information……………………………………………………………………………………………. 3
Specifications…………………………………………………………………………………………………….. 4
Main Power Connection………………………………………………………………………………….. 5
Rigging the Fixture…………………………………………………………………………………………….7
Parts List.............................................................................................................................. 7
Check that the unit has not been damaged during transport
Caution!
Read entire manual before connecting units
Protection Against Fire
1. Maintain a minimum of 1 foot distance from any type of flame.
2. Do Not install the unit too close to a heat source.
3. Make sure cable is properly secured away from unit heat sinks.
Protection Against Electrical Injury
1. Disconnect power before LED replacement or servicing.
2. This unit must be earthed. (electronically grounded)
3. Do not expose unit to rain or moisture.
Protection Against Mechanical Hazards
1. Use safety chain when hanging unit.
2. Use quality clamps or bolts when positioning unit
3. Units are hot, Do not touch when they are on
4. Do not open unit risk of electrical shock.
3
Specifications
Part Numbers
Fixture
4232– Dream Beam Nine
Mechanical Specifications
Housing: Stainless Steel
Connection: Cable mounted Cat 5 head
Accessories: Cat 5 Splitter (included)
Cat 5 cable 5 meter (included)
MR16 nickel housing
8CM Frosted tube with adapter ring
20CM Frosted tube with adapter ring
120CM Frosted tube with dual adapter ring
Fixture
Fixture Packaged for Shipping
FixtureFixture
Packaged for Shipping
Packaged for ShippingPackaged for Shipping
2”
3 .87”
3 .87”
Size: 2” x 3.87”
Weight: 1lbs
Size: 8.25”L x 3.25”W x 3.25”H
Weight: 2 lbs
LED Specifications
LED Quantity: 3
LED Type: Tri Color R,G,B
LED Watts: 3 Watts each
LED Lifetime: 50 to 100 thousand hours
LED Angle: 45° ( ± 5º )
Control
Dream Drive can control 4 Dream Beam Nine.
4..12”
2”
Dream Drive Quad can control 16 Dream Beam Nine 4 per zone
4
Main Power & Signal Connection
Caution!
1. Do not connect fixture to a dimmer system.
2. This unit must be earthed. (electronically grounded)
Single Unit Connection Using Dream Driver
Connect Dream Beam Nine connection to side of
Dream Driver panel mount connection
Multiple Unit Connection Using Dream Driver
Using the Cat 5 cable (included in package)
Connect from the output of the Dream Driver to the
input marked on the Bream Beam Splitter (included
in package). From the Out 1 on the Dream Driver
Splitter you can connect to your Dream Beam Nine.
From the Out 2 you can connect the following Dream
Beam Nine repeating the process up to 4 times. Do
not connect more than 4 units to the dream driver
Caution!
1. Do not connect more than 4 Dream Beam Nine units to the Dream Driver
2. Cable length must not exceed 150 feet total from Dream Driver to the final unit
5
Single Unit Connection Using Dream Driver Quad
Connect Dream Beam Nine connection to side of Dream Driver Quad
panel mount connection
Multiple Unit Connection Using Dream Driver Quad
Using the Cat 5 cable (included in package)
Connect from the output of the Dream Driver Quad to the input marked on
the Bream Beam Splitter (included in package). From the Out 1 on the
Dream Driver Splitter you can connect to your Dream Beam Nine. From the
Out 2 you can connect the following Dream Beam Nine repeating the process up to 4 times per zone. Do not connect more than 4 units to the Dream
Driver Quad per zone.
Caution!
1. Do not connect more than 4 Dream Beam Nine units per zone output
2. Cable length must not exceed 150 feet total from Dream Driver Quad to the final
unit per zone
6
Rigging the fixture
Caution!
1. The installations must be carried out by an authorized dealer or trained professional.
2. Unit may cause severe injures if you have doubts concerning the safety do not install.
3. Unit is to be 24inches away from flammable materials (decoration material)
4. Use high quality installation equipment to hang unit.
When rigging a unit it is very important that you follow common safety procedures. Rigging requires extensive experience including but not limited to calculating working loads, material being used and periodic safety inspections. If you lack these qualifications, do not attempt the installation yourself, instead use a professional structural rigger.
When rigging the unit always be secured with a secondary safety attachment. The installation location of the projector must be
built in the way that it can hold 10 times the weight for 1 hour with out any harming. Installation should be checked at least one
time a year by a skilled person.
Cleaning and maintenance
Installation Maintenance: The operator has to make sure that the unit is operating safely and has the installations and electron-
ics checked by an expert every 2 years.
The following points have to be considered during the inspection:
1) All screws used for installing the device or part of the device have to be tightly connected and must not be corroded.
2) There must not be any deformations on the housing, fixation and installation spots (ceiling, suspension, trussing).
3) The Cad 5 cables must not show any damages, material fatigue (e.g. porous cables) or sediments. Further instructions depending on the installation spot and usage have to be adhered by a skilled installer and any safety problems have to be removed.
Replacing the Cat 5 cable: If the power cable of this device becomes damaged, it has to be replaced by authorized dealers only
In order to avoid hazards.
Parts List
Item Number Description
4232-LEDC LED card
4232-LEDT Tri Chip LED
4232-Yoke Mounting Yoke
4230-5mCableCat 5 Cable
4230-Splitter Dream Beam Splitter
4232-Lens Dream Beam 30° lens kit
4240 Dream Frost 3
4241 Dream Frost 8
4242 Dream Frost 47
7
Ph 210-684-2600 Fax 210-855-6279
www.mega-lite.com / info@mega-lite.com
Mega-Lite
5718 Kenwick St
San Antonio, TX 78238