Medtronic SPS02514 Instructions for Use

M-12-06 LOOP TLIF
-
Cage 12 mm, 6°
M-13-06 LOOP TLIF
-
Cage 13 mm, 6°
L-07-06*
LOOP TLIF
-
Cage 7 mm, 6° klein
L-08-06*
LOOP TLIF
-
Cage 8 mm, 6° klein
L-09-06 LOOP TLIF
-
Cage 9 mm, 6° klein
L-13-06 LOOP TLIF
-
Cage 13 mm, 6° klein
L-14-06** LOOP TLIF
-
Cage 14 mm, 6° klein
L-15-06** LOOP TLIF
-
Cage 15 mm, 6° klein
L-16-06** LOOP TLIF
-
Cage 16 mm, 6° klein
L-17-06** LOOP TLIF
-
Cage 17 mm, 6° klein
MI-001B LOOP Setzinstrument Hülse
MI-002B LOOP Setzinstrument Schaft
MI-003A LOOP Positionierstab gerade
7,4
013A
MI-014A LOOP Distraktor 7 mm
MI-015A LOOP Distraktor 8 mm
MI-019A LOOP Distraktor 12 mm
MI-020A LOOP Distraktor 13 mm
MI-022 LOOP Füllhilfe
MI-026 LOOP Innenstößel
MI-027 LOOP Raspel 7 mm
MI-027/11 LOOP Raspel 11
mm
MI-027/12 LOOP Raspel 12
mm
MI-027/13 LOOP Raspel 13
mm
MI-028 LOOP Probecage 7 mm
MI-039 LOOP
Knochenstößel
.
M-08-06 LOOP TLIF
-
Cage 8 mm, 6°
M-09-06 LOOP TLIF
-
Cage 9 mm, 6°
M-10-06 LOOP TLIF
-
Cage 10 mm, 6°
M-15-06 LOOP TLIF
-
Cage 15 mm, 6°
M-16-06 LOOP TLIF
-
Cage 16 mm, 6°
M-17-06 LOOP TLIF
-
Cage 17 mm, 6°
M-18-06 LOOP TLIF
-
Cage 18 mm, 6°
L-11-06 LOOP TLIF
-
Cage 11 mm, 6° small
L-12-06 LOOP TLIF
-
Cage 12 mm, 6° small
L-13-06 LOOP TLIF
-
Cage 13 mm, 6° small
L-14-06** LOOP TLIF
-
Cage 14 mm, 6° small
L-15-06** LOOP TLIF
-
Cage 15 mm, 6° small
MI-002B LOOP
Inserter Shaft
d
straight
MI-004A LOOP Position. Rod angled
MI-005A LOOP Slap Hammer
013A
MI-014A LOOP Distractor 7 mm
MI-015A LOOP Distractor 8 mm
MI-016A L
OOP Distractor 9 mm
MI-022 LOOP Filling Aid
MI-026 LOOP Inner Pusher
MI-027 LOOP Rasp 7 mm
MI-027/7 LOOP Rasp 7 mm
MI-027/12 LOOP Rasp 12
mm
MI-027/13 LOOP Rasp 13
mm
MI-028 LOOP Trial Implant 7 mm
MI-029 LOOP Distraction Instrument
MI-030 LOOP Revision Instrument
D
GB
VERWENDUNGSZWECK:
Der LOOP Cage wurde als Implantat zur dorsalen Stabilisierung der lumbalen Wirbelsäule mit der Technik der Transforaminal Lumbar Interbody Fusion (T-LIF) entwickelt.
PRODUKTBESCHREIBUNG:
■ ARTIKELLISTE (GELTUNGSBEREICH): ■ ZUGELASSENE INSTRUMENTE LOOP: Art. Nr. Bezeichnung
M-08-06 LOOP TLIF-Cage 8 mm, 6° M-09-06 LOOP TLIF-Cage 9 mm, 6° M-10-06 LOOP TLIF-Cage 10 mm, 6° M-11-06 LOOP TLIF-Cage 11 mm, 6°
L-10-06 LOOP TLIF-Cage 10 mm, 6° klein L-11-06 LOOP TLIF-Cage 11 mm, 6° klein L-12-06 LOOP TLIF-Cage 12 mm, 6° klein
L-18-06** LOOP TLIF-Cage 18 mm, 6° klein
** Nur auf spezielle Anforderung
INDIKATIONEN: LOOP Cages sind für folgende Indikationen gedacht:
- degenerative Instabilitäten/segmentale Dysfunktionen der lumbalen Wirbelsäule
- Spondylolisthesen
- Sekundäre Instabilitäten nach operativen Eingriffen an der LWS
KONTRAINDIKATIONEN:
Kontraindikationen für LOOP sind:
- Reduzierte Knochenfestigkeit, die keine ausreichende Auflagestabilität gewährleistet (z. B. bei Osteoporose)
- Frakturen
- Tumoren
- Skoliosen
- Präsente Infektion
- Allergie gegen Titan, Titanlegierung oder PEEK
Bitte beachten Sie, dass die Stabilität des Segmentes durch v erschiedene Faktoren beeinf lusst werden kann. Das Prinzip des LOOP- Cages beruht auf einer Spannung des Annulus und der Längsbänder bei ausreichender Knochenqualität. Im Allgemeinen sollte eine zusätzliche Stabilisierung mit einem dorsalen Fix ateur (ART) in Erwägung gezogen werden.
MÖGLICHE KOMPLIKATIONEN:
Hinweis: Eine Nachoperation kann notwendig werden, um Fehlergebnisse zu korrigieren. Warnung: Ein absolut befriedigendes Ergebnis ist nicht bei all en Operationen zu erzielen. Dies gilt
insbesondere für Wirbelsäulenoperationen, in denen zahlreiche externe Faktoren das Ergebnis beeinflussen können. Die Osteosynthese mit LOOP muss immer durch eine knöcherne Fusion z wischen den Wirbeln begleitet werden. LOOP kann nur das operative Ergebnis bis zur endgültigen knöchernen F usion sichern, die in der Regel spätestens nach einem Jahr erfolgt sein sollte.
OPERATIVE VORSICHTSMAßNAHMEN:
Der Operateur muss absolut vertraut sein mit LOOP, den notwendigen Instrumenten und der allgemeinen Operationstechnik. Der Operateur muss di e speziell v on AMT für LO OP zugelassenen Instrumente verwenden. Der Operateur muss immer sicherstellen, dass die optimal e Cagegröße verwendet wird und das Implantat anatomisch korrekt pl atziert wird. Probeimplantate ermöglichen eine einfache und sichere Größenbestimmu ng. Überdistraktion ist zu vermeiden. Dabei ist darauf zu achten, dass das Implantat in korrekter anatomischer Ausrichtung platziert wird. Übermäßiges Anwinkeln bei gleichzeitig starkem Anziehen des Setzinstrumentes kann in Folge zur Schwächung des Materials und zum Bruch führen. Das operative Vorgehen kann auch in der Operationsanleitung nachgelesen werden (REF X-009). Bitte dokumentieren S ie die verwendeten Implantate patientenbezogen mit Charge, damit die gesetzlich geforderte Rückverfolgbarkeit gewährleistet ist. Die Implantate sind zum Einm algebrauch gedacht. Ein
explantiertes Implantat darf auf keinen Fall wiederverwendet werden.
VERPACKUNG:
LOOP-Implantate werden grundsätzlich einzelsteril verpackt gelief ert. Implantate nur bei unversehrter Verpackung verwenden. Die Lagerungsbedingungen müssen die Unversehrtheit der Verpackungen und damit Implantate gewährleisten. Defekte Implantate oder weitere Komponenten sind nicht zu benutzen.
REKLAMATIONEN:
Jede F achkraft (z.B. Arzt, der das P rodukt verwendet), die eine Reklamation hat, oder mit der Qualität, der Beschriftung, Zuverlässigkeit, S icherheit, Effektivität und/oder Leistung des Produktes unzufrieden ist, sollte AMT oder, wo anwendbar, den Händler informieren. Bei einem schweren Vorkommnis oder dem Risiko eines schweren Vorkommnisses, das zu einer schweren Beeinträchtigung der Gesundheit oder des Totes des Patienten oder eines Anwenders, bzw. Dritten führen kann oder geführt hat, muss AMT (oder der Händler) sofort schriftlich oder mündlich inf ormiert werden. Alle Reklamationen sollten mit Angabe von Produktname, Artikelnummer, LOT und Beschreibung sowie Daten des V orkommnisses erfolgen. Der Meldende sollte seinen Namen und Kontaktdaten angeben und das Vorkommnis möglichst detailliert beschreiben.
WEITERFÜHRENDE INFORMATIONEN:
Für weiterführende Information kontaktieren Sie bitte:
Advanced Medical Technologies AG Kasteler Strasse 11 66620 Nonnweiler DEUTSCHLAND
mail@amt-ag.de
06873-66880
GEBRAUCHSANWEISUNG
LOOP Cage
(Separate Gebrauchsanweisung)
Art. Nr. Bezeichnung
MI-004A LOOP Positi onierstab gebo-
MI-005A LOOP Gleithammer MI-006A LOOP Kürette gerade AD 7,4 MI-007A LOOP Kürette gebogen AD
MI-008A –
MI-016A LOOP Distraktor 9 mm MI-017A LOOP Distraktor 10 mm MI-018A LOOP Distraktor 11 mm
MI-027/7 LOOP Raspel 7 mm MI-027/8 LOOP Raspel 8 mm MI-027/9 LOOP Raspel 9 mm MI-027/10 LOOP Raspel 10 mm
MI-029 LOOP Distraktionsinstrument MI-030 LOOP Revi sionsinstrument MI-031­MI-037
gen
LOOP Trial Implants
LOOP Testimplantate 7 - 13 fester Griff
0482
INSTRUCTIONS FOR USE
INTENDED USE:
The LOOP Cage was developed as an implant for the posterior stabilization of the lumbar spinal column with the technique of Transforaminal Lumbar Interbody Fusion (T-LIF).
PRODUCT DESCRIPTION:
LOOP i s a banana-shaped im plant with optim ized ti p design and an integrated swivel joint for the instrument fixation. Both factors facilitate the implantation. The radial orientated f ixation teeth defi ne the direction of i m­plantation and secure the implant position. LOOP is shaped with a 6° lordosis. LOOP i mplants are made out of PEEK Optima with X-ray markers and a swivel out of titanium according to the standard ISO 5832-2 or ASTM­F 67 and ISO 5832-3 or AS TM-F 136. LOOP Cages must not be implanted in direct i nterconnection with com­ponents of other manufacturers.
LIST OF ARTICLES (AREA OF VALIDITY): APPROVED INSTRUMENTS LOOP:
(Separate Instructions for Use)
Art. Nr. Description
M-11-06 LOOP TLIF-Cage 11 mm, 6° M-12-06 LOOP TLIF-Cage 12 mm, 6° M-13-06 LOOP TLIF-Cage 13 mm, 6° M-14-06 LOOP TLIF-Cage 14 mm, 6°
L-07-06 LOOP TLIF-Cage 7 mm, 6° small L-08-06 LOOP TLIF-Cage 8 mm, 6° small L-09-06 LOOP TLIF-Cage 9 mm, 6° small L-10-06 LOOP TLIF-Cage 10 mm, 6° small
L-16-06** LOOP TLIF-Cage 16 mm, 6° small L-17-06** LOOP TLIF-Cage 17 mm, 6° small L-18-06** LOOP TLIF-Cage 18 mm, 6° small
** Only upon special request
INDICATIONS: (Outside US)
- degenerative instabilities/segmental dysfunctions of the lumbar spine
- Spondylolisthesis
- Secondary instabilities after lumbar surgeries
INDICATIONS: (US)
The LOOP Cage is indicated for intervertebral body spinal fusion procedures in skeletally mature patients with degenerative disc disease (DDD) at one level from L2-S1. DDD is defined as discogenic back pain with degene­ration of the disc confirmed by patient history and radiographic studies. These DDD patients may also have up to Grade I spondylolisthesis or retrolisthesis at the involved level. LOOP imp lants are to be used in combination with autogenous bonegraft and implanted via an open posterior approach. The LOOP Cage is to be used with supplemental fixation. Patients should have at least six (6) months of non-operative treatm ent prior to treatment with an intervertebral cage,
CONTRAINDICATIONS:
- Reduced bony density, which does not guarantee a sufficient resting stability (e. g. Osteoporosis)
- Fractures
- Tumors
- Scoliosis
- Active infection
- Allergy to titanium, titanium alloy or PEEK
Please take into consideration that the segmental stability can be affected by a variety of fact ors. The principal of the LOOP-Cage is founded on a tension of the annulus and the longitudinal ligaments in case of sufficient bone quality. (Outside US: Generally an additional stabilization with a posterior fixation system (ART) should be considered.)
POSSIBLE ADVERSE EFFECTS: Note: A further surgery might become necessary to correct adverse effects.
Warning: An entirely satisfactory result is not always achieved in every surgical case. This particularly applies to spinal surgery, in which numerous external factors may compromise the results. The osteo­synthesis achieved with LOOP implants must obligatorily be accompanied by an arthrodesis on t he concerned vertebras. LOOP can only secure the surgical result until the definite bony fusion i s reached, which should normally be the case after one year at the latest.
OPERATIVE PRECAUTIONS:
The surgeon must be perfectly familiar with LOOP, the necessary instruments and the general surgical tech­nique. The surgeon must use the instruments especially approved by AMT for LOOP. The surgeon has to take care that the optimum cage size is used and the implant is placed anatomically correct. Trial impl ants enable a simple and safe size destination. Overdistraction is to be avoided. The surgeon has to pay attention that the im­plant is placed in a correct anatomical direction. Excessive angeling combined with strong fixation of the inser­ter can cause weakening of the material and thus breakage. The general surgical procedure can be learned out of the surgical technique (REF X-009). It is available upon request. Please document the used implants per pa­tient with Lot-No., so that the tracking back, which is required by law, is guaranteed. The implants are only for single use. It is not allowed to reuse an explanted implant.
PACKING:
The LOOP implants are packed single sterile. Only use the im plants when packing is undamaged. The implants are intended f or single use only. Each package contains documentation labels for your disposal. The package and the labels as well include all inform ation required. You can learn the item-no., Ref. , the Lot-No. LOT, the description, the sterilisation method, the quantity and the manufacturer from the labels.
COMPLAINTS:
Any heathcare professional (e. g. a surgeon using a product) who has a complaint or who is dissatisfied with the quality, identification, reliabili ty, safety, efficacy and/or performance of LOOP products should notify AMT or, where applicable, the distributor. In the ev ent of a serious incident or risk of a serious incident l iable to result in, or to have resulted in, the death or serious deteriorati on in the state of health of a patient or user, AMT (or the disributor) should be notified as soon as possible by telephone, fax or letter. All complaints should be accompa­nied by the name(s), reference(s) and batch number(s) of the incriminated component(s). The person formulat­ing the complaint should state his nam e, address and t he nature of the complaint, giving as many details as possible, and state the required response.
FURTHER INFORMATION:
For further information, please contact:
Advanced Medical Technologies AG Kasteler Strasse 11 66620 Nonnweiler Germany
mail@amt-ag.de
+49-6873-66880
LOOP Cage
Art. Nr. Description
MI-001B LOOP Inserter Tube
MI-003A LOOP Positioning Ro
MI-006A LOOP Reamer Straight OD
MI-007A LOOP Reamer angled AD 7.4 MI-008A-
MI-017A LOOP Distractor 10 mm MI-018A LOOP Distractor 11 mm MI-019A LOOP Distractor 12 mm MI-020A LOOP Distractor 13 mm
MI-027/8 LOOP Rasp 8 mm MI-027/9 LOOP Rasp 9 mm MI-027/10 LOOP Rasp 10 mm MI-027/11 LOOP Rasp 11 mm
MI-031 – MI-037 MI-039 LOOP Bone Pestle
REF X-005, LOT 2007/11
7.4
LOOP Trial Implants
LOOP Trial Implants 7 – 13, Fix Handle
0482