Medtronic KDR603 Addendum

Kappa® 700/600 Series
Pacemaker Reference Guide
Pacemaker Reference Guide Supplement
Caution: Federal Law (USA) restricts this device to sale by or on the order of a physician (or properly licensed practitioner).
The following are trademarks of Medtronic: Capture Management, Checklist, FAST, Fast Path, Implant Detection, Kappa, Key
Parameter History, Marker Channel, Medtronic, Medtronic Kappa, Medtronic Vision, Rate Profile Optimization, Remote Assistant, Auto-PVARP, Quick Look, Quick Secure, Search AV, Sensing Assurance, Significant Events, Sinus Preference, Ventricular Pace Preference, and Vision.
Supplement – Medtronic Kappa 700/600 Series Pacemaker Reference Guide

Addition to Chronic Lead Trend information

Chronic Lead Trend data is collected in all pacing modes except for triggered pacing modes (AAT and VVT). This data is not collected in non-pacing modes (OAO, OVO, and ODO).
The revised information applies to the following sections:
Chapter 4, section "Automatic Lead Impedance (Chronic Lead Trend)"
Chapter 6, section "Chronic Lead Impedance Trend"
Chapter 8, section "Automatic Diagnostics"

Addition to Clinician-Selected Lead Impedance Detail diagnostic information

The clinician-selected Lead Impedance Detail diagnostic records impedance minimum and maximum values. Impedance values are not collected for triggered pacing modes (AAT and VVT) or for non-pacing modes (OAO, OVO, and ODO).
The revised information applies to the following sections:
Chapter 4, section "Clinician-Selected Lead Impedance Detail"
Chapter 8, section "Clinician-Selected Diagnostics"

Revision to PMT Intervention settings

The revised information applies to Appendix B, tables B-8 and B-17.
Table 1. PMT Intervention Preset Settings
PMT Intervention Setting
Shipping Off Off
Nominal Off Off
DR700 Series,
K
DR600 Series
K
K
D700 Series, VDD700 Series
K
K
SR700 Series
World Headquarters
Medtronic, Inc. 710 Medtronic Parkway Minneapolis, MN 55432-5604 USA Internet: www.medtronic.com Tel. 763-514-4000 Fax 763-514-4879
Asia
Medtronic International Ltd. Suite 1602 16/F, Manulife Plaza The Lee Gardens, 33 Hysan Avenue Causeway Bay Hong Kong Tel. 852-2891-4068 Fax 852-2591-0313
Medtronic USA, Inc.
Toll-free in the USA (24-hour technical consultation for physicians and medical professionals) Bradycardia: 1-800-505-4636 Tachycardia: 1-800-723-4636 Heart Failure: 1-800-505-4636
Europe/Africa/Middle East Headquarters
Medtronic Europe Sàrl Route du Molliau 31 Case Postale CH-1131 Tolochenaz Switzerland Internet: www.medtronic.co.uk Tel. 41-21-802-7000 Fax 41-21-802-7900
Medtronic E.C. Authorized Representative/Distributed by
Medtronic B.V. Earl Bakkenstraat 10 6422 PJ Heerlen The Netherlands Tel. 31-45-566-8000 Fax 31-45-566-8668
Australia
Medtronic Australasia Pty. Ltd. Unit4/446VictoriaRoad Gladesville NSW 2111 Australia Tel. 61-2-9879-5999 Fax 61-2-9879-5100
Canada
Medtronic of Canada Ltd. 6733 Kitimat Road Mississauga, Ontario L5N 1W3 Tel. 905-826-6020 Fax 905-826-6620 Toll-free in Canada: 1-800-268-5346
Japan
Medtronic Japan Solid Square West Tower 6F, 580 Horikawa-cho, Saiwai-ku, Kawasaki, Kanagawa 210-0913 Japan Tel. 81-44-540-6112 Fax 81-44-540-6200
*A09686001*
© Medtronic, Inc. 2004 UCXA09686001 A09686001 2004-10-29
Loading...