5 W a r r a n t y . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 4
Please fold out this page and leave it folded out for
quick reference.
Device and control
s
GB
Water tank
Mist outlet
ON/OFF switch and rotary knob
for controlling mist intensity
ON/OFF button for night illumination
GB
1 Safety Information
IMPORTANT INFORMATION!
RETAIN FOR FUTURE USE!
Read the instruction manual carefully before using this device, especially the
safety instructions, and keep the instruction manual for future use.
Should you give this device to another person, it is vital that you also pass on
these instructions for use.
Explanation of symbols
This instruction manual belongs to this device.
It contains important information about starting up
and operation. Read the instruction manual thoroughly.
Non-observance of these instructions can result in
serious injury or damage to the device.
WARNING
These warning notes must be observed to prevent
any injury to the user.
CAUTION
These notes must be observed to prevent any
damage to the device.
NOTE
These notes give you useful additional information
on the installation and operation.
Lot number
Manufacturer
8
Safety
Information
1 Safety Information
Power supply
• Before connecting the device to your power supply, please ensure that the
supply voltage stated on the rating plate is compatible with your mains
supply.
• Only connect the mains plug to the wall socket when the device is switched
off.
•
Never carry, pull or turn the device by the electricity cable and do not squeeze
the cable.
• Position the mains cable so as to avoid the danger of falling.
• Do not touch the mains plug when you are standing in water and always take
hold of the plug with dry hands.
For special people
• This device is not designed to be used by persons (including children) with
limited physical, sensory or mental abilities, or by persons with insufficient
experience and/or knowledge, unless under observation by a person responsible for their safety, or unless they have been instructed in the use of the
device.
• Children must be supervised to ensure that they do not play with the device.
• In the event of an allergic respiratory problem, consult your doctor before
using the appliance.
• Should you experience medical complaints during use talk to your doctor.
Should this be the case, stop using the device immediately.
Operating the device
• The device is not determined for commercial use.
• Only use the device for its intended use as in the instruction manual. If
misused, all guarantee rights shall become null and void.
• Do not use the device if it or the power supply cable is damaged, if it does
not work properly or if it has been dropped or fallen into water.
• Keep the device and its power cable away from hot surfaces.
• Place the device on a firm floor area when in use so that it cannot tip over.
• Do not take hold of a device if it falls into water. Unplug the mains cable
immediately.
• Do not use the device if the water tank is empty or does not contain enough
liquid.
•
Do not use distilled oils (e.g. eucalyptus or menthol), since these could damage
the device.
• Keep the ventilation slits on the underside of the unit free of dust and
impurities.
• Switch off all functions after use and remove the plug from the mains
supply.
Maintenance and cleaning
• You may only clean the device yourself. If the device malfunctions do not
repair it yourself as this leads to the automatic expiry of all guarantee rights.
Ask your specialist dealer and have repairs carried out by the MEDISANA
service.
• Do not immerse the device in water or other fluids.
GB
9
GB
1 Safety Information / 2 Useful Information
2 Useful Information
• If, nonetheless, liquid should penetrate the device, unplug the mains cable
immediately.
• Store the unit in a dry place.
Thank you
very much
2.1
Items supplied
and packaging
2.2
Intensive
personal
humidifier
Thank you for your confidence in us and congratulations on your purchase!
You have acquired a quality product with your purchase of the MEDISANA
personal humidifier UHW. To ensure the best results and long-term satisfaction
with your MEDISANA personal humidifier UHW, we recommend that you read
the following operating and maintenance instructions carefully.
Please check first of all that the device is complete and is not damaged in any
way. In case of doubt, do not use it and contact your supplier or your service
centre. The following parts are included:
• 1 MEDISANA personal humidifier UHW
• 1 Cleaning brush
• 1 Instruction manual
The packaging can be reused or recycled. Please dispose properly of any
packaging material no longer required. If you notice any transport damage
during unpacking, please contact your supplier without delay.
WARNING
Please ensure that the polythene packing is kept away from the
reach of children! Risk of suffocation!
Very dry air increases susceptibility to infection and respiratory diseases and
leads to fatigue and lack of concentration. Healthy air should have a relative
atmospheric humidity of 40 to 55 %. The quiet, energy-saving ultrasound technology of the personal humidifier uses oscillation to convert water into a fine
mist that increases the moisture level of the air. This improves the air quality
and prevents the mucous membranes and skin from drying out.
The capacity of the device is suitable for a room with a maximum area of
30 m2. You can adjust the level of humidity to the size of the room using
the knob for the mist intensity .
Pay special attention to the notes on cleaning and care.
10
CAUTION
Over-intensive operation can result in saturating the room with
moisture, which can affect the walls, windows and objects in
the room. Therefore, use a hygrometer at regular intervals to
check that the level of relative air humidity does not exceed
55%.
3 Operating
CAUTION
Make sure that the MEDISANA air humidifier is operated on a
surface which is resistant to water, and that it cannot tip over.
In particular, when operated with mineralised water / aromatic
essences, condensation / residues may be produced.
You can turn the the mist outlet . Make sure that the mist
being issued is not directed towards electronic appliances,
furniture or walls.
GB
3.1
Filling and
emptying the
water tank
3.2
Switching the
unit on and off
Detach the water tank from the device and turn it over. Unscrew the cap.
Rinse out the water tank and then fill it up with a maximum of 4.2 l drinking
water. Seal the tank again by screwing the cap back in. Turn the water tank
over again and place it back in the device so that it audibly engages. Do not
move the unit when the water chamber is full. Dispose of the leftover water
after use and rinse out the tank with fresh drinking water. Before using again,
fill the tank with fresh drinking water. When you have switched off the unit
and do not intend to use it for an extended period of time, remove and empty
the water tank.
CAUTION
Only use fresh drinking water in the device. You can also use
demineralised water, if the water is very hard and calciferous.
Clean the device at regular intervals and remove lime and other
deposits, to maintain its efficiency.
Plug the device into a properly installed power socket. Switch on the personal
humidifier by turning the ON/OFF switch and the knob for the mist intensity
from OFF to ON. The built-in LED lights up green under the water tank. When
the water tank is empty, it lights up red.
Then set the device depending on the room requirements at a position from
the lowest to the highest blower intensity. After a few seconds the mist
from the outlet will be visible.
Switch the device off after use or when the water in the tank has almost been
used up (the LED lights up red) by moving the ON/OFF switch and the rotary mist
intensity knob to OFF. The device switches itself off automatically when the
water tank is empty. The device has a blue night illumination. When the device is
switched on, press the ON/OFF button for the night illumination
button
again to switch off the night illumination.
. Press the
3.3
Operating time
Operation time is approx. 20 hours at the maximum setting (230 ml/h) with
4500 ml of water.
11
GB
3 Operating / 4 Miscellaneous
3.5
Faults and Fault
Remedying
4 Miscellaneous
4.1
Cleaning and
maintenance
• Device will not switch on (LED not illuminating): Plug in the plug; Check power
circuit, socket and fuse.
• No mist (LED lights up red): Fill water tank.
• No mist although tank full: Move rotary knob to ; Place device on a level
surface; Clean atomiser and generator using provided brush and fill tank with
clean water; Rinse device with clean water.
• White deposits: Use clean water or at least 1/2 distilled water / 1/2 fresh tap
water. If a fault cannot be remedied using the described method, please
contact your service centre.
• During everyday use it is advisable to give the device a thorough cleaning at
least every three days. Also clean device before and after long storage periods.
• Before cleaning the device, make sure that it is turned off and the mains plug
is removed from the socket.
• Remove the water tank from the device and empty it.
• Clean the outside of the unit with a soft, damp cloth.
• Please do not use any aggressive substances for cleaning, such as scouring
cream or other detergents, as these may damage the surfaces and reduce the
atomisation effect.
• You can rinse out the water tank with hot water (>65 °C) or an alcohol of at
least 75 % vol. The atomiser chamber should be cleaned using an alcoholsoaked cloth and cotton bud. Take care to ensure that no water gets inside
the humidifier.
• The ultrasound generator is the most sensitive component in the device. It is
important for it to be kept clean and handled with care. Please use the provided brush to remove deposits and dirt particles from the outlets. Never clean
the ultrasound generator using metal objects.
• If you do not intend to use the unit for an extended period of time, empty any
remaining water from the tank and dry off the unit.
• Limescale can be removed using a mild descaling agent such as citric acid.
• Store the unit in a cool, dry place, preferably in its original packaging.
• Remove cap from underside of the water tank and store separately to prevent
sleeve gasket from sticking.
4.2
Disposal
12
This product must not be disposed of together with domestic waste.
All users are obliged to hand in all electrical or electronic devices, regardless
of whether or not they contain toxic substances, at a municipal or commercial collection point so that they can be disposed of in an environmentally
acceptable manner.
Consult your local authority or your supplier for information about disposal.
4 Miscellaneous
GB
4.3
Technical
specifications
Name and model : MEDISANA personal humidifier UHW
Current supply : 220 - 240 V~ 50 Hz
Output : approx. 32 W
Tank contents: 4.2 l
Atomizer capacity : maximum 230 ml/h
Dimensions W x H x D : approx. 26.5 x 33 x 20 cm
Weight : approx. 2025 g
Storage conditions : clean and dry
Item number : 60065
EAN number : 40 15588 60065 4
In accordance with our policy of continual product improvement,
we reserve the right to make technical and visual changes
without notice.
13
GB
5 Warranty
Warranty and
repair terms
Please contact your supplier or the service centre in case of a claim under the
warranty. If you have to return the unit, please enclose a copy of your receipt
and state what the defect is.
The following warranty terms apply:
1. The warranty period for MEDISANA products is three years from date of
purchase. In case of a warranty claim, the date of purchase has to be
proven by means of the sales receipt or invoice.
2. Defects in material or workmanship will be corrected free of charge within
the warranty period.
3. Repairs under warranty do not extend the warranty period either for the
unit or for the replacement parts.
4. The following is excluded under the warranty:
a. All damage which has arisen due to improper treatment, e.g. non-
observance of the user instructions.
b. All damage which is due to repairs or tampering by the customer or
unauthorised third parties.
c. Damage which has arisen during transport from the manufacturer to the
consumer or during transport to the service centre.
d. Accessories which are subject to normal wear and tear.
5. Liability for direct or indirect consequential losses caused by the unit are
excluded even if the damage to the unit is accepted as a warranty claim.