MED-EL RONDO Quick Manual

RONDO®
Single-Unit Audio Processor
Quick Guide
RONDO® Single-Unit Audio Processor
Indicator Lights
Attachment Clip Fixture
(Available on both sides)
Microphone/
Microphone Cover
Battery Pack
Switch Release Lever
Air Inlet
Control Unit
Table of Contents
Basic Assembly ........................... 2
Indicator Lights ........................... 4
FineTuner ............................... 6
FineTuner Light Patterns .................... 8
Batteries ................................ 9
Telecoil Accessories ....................... 10
Mini Battery Pack ........................ 12
Assistive Listening Devices ................ 14
Accessories ............................. 16
Basic Care and Maintenance ................ 18
Troubleshooting ......................... 20
UnlockedOFF/
Locked
ON
1
Basic Assembly
Install and lock the
magnet into the control unit.
1
Insert the batteries with positive (+) poles facing out.
2
Ensure the switch is set to the unlock position. Hold down the relase lever while setting the switch to
unlock position.
3
Slide the battery pack into the control unit
1
, push
down
2
, and slide the switch
to locked position (
).
4
The switch must always be in the unlocked position (
) prior to attaching to
the control unit.
RONDO
Installation
Unlock
Lock
Note the mechanism that secures the control unit to the battery pack.
Hold down the
release lever.
1
Slide the switch to unlock position
(
) and lift the
battery pack up.
2
Opening the Battery Pack
Removing Batteries
The bottom side of the control unit can be used to easily lift batteries out of the
battery pack.
MED-EL strongly recommends that you don’t change the magnet yourself. Contact your clinician to have the magnet changed or if you experience any skin irritation.
1
1
2
2
Release
Lever
2 3
Status
Batteries are empty.
Either minimum or maximum volume has been reached, or audio sensitivity has been reached.
Warning
Problem
Temporary error or electronic malfunction.
The setting you selected has not yet been programmed, or there has been a program malfunction.
Temporary error or electronic malfunction.
Programming failure, temporary error, or electronic malfunction.
Error Pattern Solution
1. Turn pro cessor off.
2. Turn pro cessor back on.
Select another setting.
1. Turn pro cessor off.
2. Turn pro cessor back on.
1. Turn pro cessor off.
2. Turn pro cessor back on.
Solution
Change the batteries.
Adjust volume or sensitivity if necessary.
Status
FineTuner command has been successfully received.
Program 1 is selected.
Program 2 is selected.
Program 3 is selected.
Program 4 is selected.
Conrmation
If the optional status light has been activated: RONDO is initialised and working.
Status
Program Change
Scale in Seconds
10 2 3
Scale in Seconds
10 2 3
Indicator Lights
RONDO4 5
Volume
Increase or decrease the volume
Program Selection
Choose a program
Default Volume and Sensit ivity
Set volume and audio sensitivity to default setting as determined by your audiologist
Sensitivity
Increase or decrease the audio sensitivity
Input Selection
M: Selects the microphone MT: Selects microphone and telecoil T: Selects the telecoil
Processor Selection (For Bilateral Users)
Select the left processor, both processors, or the right processor; Activates and deactivates the Keypad Lock
1
2
3
4
5
6
FineTuner
RONDO
Sensitivity
Input Selection
Processor Selection (For Bilateral Users) and Keypad Lock Feature
Volume
Program Selection
Indicator Lights
Default Volume and Sensitivity
1
2
3
4
5
6
FineTuner Keypad Lock
To prevent accidental setting changes, you can activate the FineTuner Keypad Lock. If any key is pressed while the keypad is locked, the red LED light on the FineTuner will blink.
Temporarily Unlocking the Keypad
You can make a selection even when the keypad is locked by pressing any given key twice. The rst click temporarily unlocks the keypad, and the second click sends the command.
When the Keypad Lock is temporarily deactivated, the keypad will relock after 10 seconds of inactivity.
Activating the Keypad Lock
1. Press and hold the ( ) key for 5 seconds, or until the red and amber lights blink alternately.
2. Press the (
) key. When the keypad has been locked successfully, the amber lights will blink.
Deactivating the Keypad Lock
1. Press the ( ) key twice. The second time, press and hold for at least 5 seconds, or until the red and amber lights blink alternately.
2. Press the (
) key. The amber lights will blink to indicate that your FineTuner is unlocked.
Any FineTuner key can be deactivated by your clinician to prevent accidental setting changes.
6 7
+ 5 seconds
Meaning
Keypad is locked
Information is being transmitted
Input side change
Programming mode
Batteries are low
Conguration has
been successful
Explanation
If you press any key while the FineTuner is locked, the red indicator lights will turn on.
The indicator lights blink when signals are being transmitted. The left lig ht blinks if the left side is activated. The right light blinks if the right side is activated. Both blink if both sides (for bilateral users) are activated.
Press the left key to send commands to the left side. Press the right key to send commands to the right side. The corresponding amber light will turn on. To send commands to both sides (for bilateral users), press the centre key. Both amber lights w ill turn on.
Press for more than 5 seconds to activate programming mode. The 3 indicator lights will ash alternately.
If batteries are low, the red indicator light in the centre will repeatedly blink three times.
If conguration of your FineTuner has b een successful or if the automatic keyboard lock feature has been either activated or deactivated, both amber lights will turn on for one second.
Light Pattern
Light Patterns
FineTuner
Batteries
Use only type 675 batteries to power your RONDO. We recommend using zinc-air batteries that are designed especially for hearing implant systems. When you use RONDO with the WaterWear accessory, however, you must substitute zinc-air batteries with one of the other types.
675 Zinc-Air Batteries
675 Silver-Oxide Batteries
675 Alkaline Batteries
675 Rechargeable Batteries
Maximum battery life 75 hours 10 hours 8 hours 8 hours
Requires oxygen supply
Yes No No No
Compatible with WaterWear
No Yes Yes Yes
RONDO8 9
Look for the symbol that identies the use of an induction loop system at venues.
For Neckloops and Silhouettes For Induction Loop Systems
Neckloop Accessory
Microphone with Telecoil
Microphone with Telecoil
Telecoil Only
Telecoil Only
Microphone OnlyMicrophone Only
FineTuner Input Selection Keys
FineTuner Input Selection Keys
Telecoil Accessories
RONDO − Assistive Listening Devices
Insert the 3.5 mm plug of the telecoil accessory into the headphone jack of the audio device.
1
Find the listening area of the induction loop system and stay within it.
1
Press the MT or T button on your
FineTuner to activate
the telecoil and select the input type.
2
Press the MT or T button on your FineTuner to activate the telecoil function and select the input type.
2
Place the telecoil accessory around your neck if you’re using a neckloop or on your ear if you’re using a silhouette.
3
10 11
Mini Battery Pack
RONDO
RONDO Connector
Release Lever
Microphone Test Device Port (CS 44)
DaCapo Rechargeable Battery Compartment
AAA Battery Compartment
3-Pin FM Port
ON/OFF and Battery Compartment Lock
Basic Assembly
RONDO − Mini Battery Pack
Slide the MBP
connector into the control unit.
1
Press the two release levers and lift the connector up.
Connect the connector
cable to the M B P.
2
Removing the Connector
Note the mechanism that secures the control unit to the battery pack.
The MBP can use either a single AAA battery or a DaCapo rechargeable battery.
1
2
12 13
Direct Audio Input FM Receiver
Assistive Listening Devices
RONDO − Mini Battery Pack
Insert the 3-pin plug of the
audio adapter cable into the FM port.
1
Insert the FM receiver into the FM port. RONDO will automatically detect sound signals as soon as the FM system is activated.
Insert the 3.5 mm plug of the audio adapter cable into the headphone port of the audio device.
2
Refer to the user manual for your FM system for instructions on changing FM settings.
Unilateral Mix
Audio Adapter Cables
Unilateral Ext.
Bilateral Mix
Bilateral Ext.
14 15
Accessories
Attachment Clip
The attachment clip should be used to secure RONDO to clothing or hair to reduce the risk of losing or damaging the processor.
Fixation Loop for Glasses
The xation loop can be used to secure RONDO to a pair of glasses or sunglasses.
RONDO Protector
The RONDO Protector is a soft silicone cover that should be used to protect RONDO from fall damage and other minor impacts.
WaterWear
WaterWear is a waterproof cover that provides complete water protection for RONDO. Only silver-oxide, alkaline, or rechargeable batteries should be used with WaterWear.
RONDO16 17
Basic Care and Maintenance
Follow these basic and important care instructions to help improve the functioning of your RONDO and extend its life.
General Cleaning
Clean RONDO regularly by wiping it with a soft, damp cloth. Don’t use cleaning solutions. Use extra care when cleaning small parts such as the battery contacts.
Battery Contacts
Inspect the battery contacts regularly; clean and dry them as necessary. To clean them, use a cotton swab and a small amount of rubbing alcohol. Gently wipe them dry. Avoid touching the battery contacts.
Moisture
Protect RONDO from exposure to water. If your audio processor gets wet, gently wipe it dry with a soft absorbent cloth.
Sunlight
Don’t leave RONDO in direct sunlight, especially inside of a vehicle. Don’t expose your audio processor to extreme temperatures.
Drying
Use the drying kit every night to allow RONDO to dry out completely. Remove the battery pack cover before putting it into the drying kit with your audio processor. Disposable batteries can be left in the frame and put into the drying kit.
Refer to your user manual for more information about care and maintenance.
RONDO
Don’t put rechargeable batteries into the drying kit.
18 19
Troubleshooting
In case you encounter any minor technical problems, such as an interruption in sound, carefully follow these steps to identify possible causes and solutions:
1. Remove your RONDO and change the batteries. If that doesn’t solve the problem, go to 2.
2. Disassemble your RONDO and check each part for dirt or signs of damage. Gently clean any processor parts that are dirty and wipe dry any parts that are wet. (See instructions on pages 22–23.) If any parts appear damaged, contact your CI centre for assistance.
3. Reassemble RONDO. (See instructions on pages 2–3.) If your processor still isn’t working, go to 4.
4. Use the Speech Processor Test Device to troubleshoot your audio processor.
Speech Processor Test Device
The Speech Processor Test Device (SPTD) is a troubleshooting tool for detecting the most common audio processor problems. To troubleshoot with the SPTD, follow these steps:
1. Switch on your RONDO.
2. Place the at side of RONDO under the Speech Processor Test Device.
3. Speak into the RONDO microphones. The indicator light should icker to the rhythm of your voice. If it doesn’t, go to 4.
4. Adjust the volume and speak into the microphones. If the indicator light doesn’t icker, go to 5.
5. Change the batteries and speak into the microphones. If the indicator light doesn’t icker, contact your CI centre.
For complete troubleshooting instructions, visit medel.com.