M E A S U R E M E N T S Y S T E M S I N T E R N A T I O N A L
MSI-150 Sky-Weigh • User Guide Page 7
Front Indicators
LB/KG Indicator: The MSI-150XM will display the weight in pounds or
kilograms as selected by Switch 2 of the 9 position dip switch on the side of the
instrument. The selected units are indicated by one of two pointers to the left of
the liquid crystal display.
INSTALLATION
Install the system in accordance with the installation drawing(s) provided.
Warning: After load cell/hook installation, move the hook to all positions to
insure that there is no interference with electrical/mechanical release cables.
Prior to inserting the indicator in the instrument panel, perform a “Power-On”
check to assure that the meter performs a proper TEST sequence.
CALIBRATION
The system has been factory calibrated using known weights. A periodic
calibration check should be performed by lifting a known weight (at least one
half capacity). If recalibration is required, the following procedures should be
followed:
1) Place the instrument in a position which permits access to the rear
controls.
2) Apply power and zero the unit with the rear Zero control screw.
3) Without the known weight applied, lift all slings, long line etc. to be
utilized in the lift and allow the display to stabilize then depress the Zero
control screw. This allows net weight calibration of the known weight.
4) Lift the known weight, allow the reading to stabilize then adjust the rear
Span adjustment until the known weight is indicated.
5) Remove the known weight. If the indicator returns to zero, the calibration is complete. If not, repeat steps 3 through 5.
OPERATION
1) Prior to each flight, visually inspect the load cell and attachments for
any obvious signs of wear or loose connections.
2) At power application, the indicator will automatically perform its Test
sequence.
3) With all lifting slings, long line etc. attached, depress ZERO control and