Warranty
Measurement Specialties, Inc. accelerometers are warranted during a period of one year from date of shipment to original purchaser to be free from defects in material and workmanship. The liability of Seller under this warranty is limited to replacing or repairing any instrument or component thereof which is returned by Buyer, at his expense, during such period and which has not been subjected to misuse, neglect, improper installation, repair, alteration, or accident. Seller shall have the right to final determination as to the existence and cause of a defect. In no event shall Seller be liable for collateral or consequential damages. This warrant is in lieu of any other warranty, expressed, implied, or statutory; and no agreement extending or modifying it will be binding upon Seller unless in writing and signed by a duly authorized officer.
Receiving Inspection Every Measurement Specialties, Inc.
accelerometer is carefully inspected and is in perfect working condition at the time of shipment. Each accelerometer should be checked as soon as it is received. If the unit is damaged in any way, or fails to operate, a claim should immediately be filed with the transportation company.
Service Concerns
If a Measurement Specialties, Inc. instrument requires service, first contact the nearest Measurement Specialties, Inc. representative. They may be able to solve the problem without returning the unit to the factory. If it is determined that factory service is required, call Customer Service at the regional headquarters for an RMA number before return.
Returns
All units being returned to the factory require an RMA (Return Material Authorization) number before they will be accepted. This number may
be obtained by calling Customer Service at the regional headquarters with the following information; model number(s), quantity, serial number(s), and symptoms of the problem, if being returned for service. You must include the original purchase order number if under warranty.
Recalibration Services
The Vibration Sensors Design Center and its two manufacturing facilities in China and France offer factory re-calibration services for Piezoresistive, Piezoelectric and Integrated Electronics Piezoelectric (IEPE, ISOTRON, ICP, etc.) accelerometers. NIST (US), DKD (Germany), COFRAC (France) traceable calibration services on sensitivity at 100 Hz (102 or 120 Hz in Europe) and full frequency sweeps are offered. Contact the regional headquarters for pricing information.
Inquiries
Address all inquiries on operation or applications to your nearest Sales Representative, or to the Vibration Applications Support as follows:
Global Headquarters
1000 Lucas Way Hampton, VA 23666, USA Tel: +1 757 766 1500
Vibration Sensors Design Center
32 Journey, Suite 150 Aliso Viejo, CA 92656, USA Tel: +1 949 716 7324
European Headquarters
Impasse Jeanne BENOZZI CS 83 163, 31027 Toulouse Cedex 3, France Tel: +33 (0) 582 08 22 00
Asian Headquarters
Measurement Specialties (China), Ltd. No. 26 Langshan Road Shenzhen High-Tech Park (North) Nanshan District, Shenzhen 518057, China Tel: +86 755 3330 5088
Measurement Specialties, Inc. www.meas-spec.com +1 949-716-5377 32 Journey, Suite 150, Aliso Viejo, CA 92656 USA 2 of 8 t&m@meas-spec.com
Operating Manual
TM TM
Mounting screws Torque to 3 lb-in (0.3 Nm)
Description
The Model 4623 is a signal conditioned and temperature compensated MEMS accelerometer offering high sensitivity in ranges from ±2g to ±100g. The DC response accelerometer offers outstanding performance over a wide operating temperature range and incorporates an EMI/EMC protection circuitry for harsh installations. The output is filtered and signal conditioned to provide a low noise amplified signal with exceptional resolution. The Model 4623 accelerometer incorporates a rugged strain relief for demanding applications and is packaged in an anodized aluminum housing.
Installation
The model 4623 accelerometer is designed to be screw mounted but can also be adhesively mounted if the installation does not allow for screw mounting.
Screw Mounting
For screw mounting of accelerometers the following guidelines should be followed:
The mounting surface should be clean and free of any residue or foreign material.  The mounting surface should be smooth, flat, and with a maximum surface roughness of 32 micro-
inches rms.
Optional: Apply a light coating of coupling fluid (machine oil or silicone grease) on the mating surface
to maximize the usable frequency range.
Torque screws to recommended limits using steel washers under the heads of the mounting screws.
Use manual torque wrench (do not use electric tools).
Measurement Specialties, Inc. www.meas-spec.com +1 949-716-5377
32 Journey, Suite 150, Aliso Viejo, CA 92656 USA 3 of 8 t&m@meas-spec.com
Operating Manual
TM TM
Adhesive Mounting
To avoid damaging the accelerometer during subsequent removal, it is recommended to use an adhesive mounting adaptor for this method of attachment. For adhesively mounting of accelerometers the following guidelines should be followed:
The mounting surface should be clean and free of any residue or foreign material.  The mounting surface should be smooth, flat, and with a maximum surface roughness of 64 micro-
inches rms.
For best high frequency performance a cyanoacrylate adhesive is recommend. A thin layer offers
best frequency response.
Soften adhesive cured adhesive with a chemical debonder (eg. acetone) prior to removal. Gently
shear accelerometer loose from the mounting surface after waiting a few minutes for the debonding agent to penetrate the epoxy. Make sure not to use excessive force as this may damage the accelerometer.
Biaxial Mounting Configurations
The model 4623 accelerometer has a unique housing that enables it to be mounted in two different orientations to measure either the normal or transverse acceleration input. By simply rotating the housing 90 degrees, the accelerometer can now be used to measure transverse motion. The two mounting orientations are illustrated below.
Measurement Specialties, Inc. www.meas-spec.com +1 949-716-5377 32 Journey, Suite 150, Aliso Viejo, CA 92656 USA 4 of 8 t&m@meas-spec.com
Operating Manual
TM TM
Wiring The accelerometer is designed to be operated from 7-30Vdc excitation and provide a ±2V full scale
output with a 2.5V reference voltage. The output is DC-coupled and can be used in either single-ended or differential mode. Differential mode offers the best performance since common mode errors are minimized. The electrical hookup for both modes of operation is detailed below.
Single-Ended Operation
For single-ended operation a 2.5Vdc bias will be present on the output leads and the output of the accelerometer will be 0.5-4.5V full scale. For single-ended operation the accelerometer should be connected to the signal conditioner as detailed below. To avoid permanently damaging the
accelerometer, the white wire should not be connected to ground.
SINGLE ENDED OUTPUT
Differential Operation
For differential operation the output of the accelerometer will be ±2V full scale without a bias voltage present. For differential operation the accelerometer should be connected to the signal conditioner as detailed below. Common mode voltage is 2.5V.
DIFFERENTIAL OUTPUT
Measurement Specialties, Inc. www.meas-spec.com +1 949-716-5377 32 Journey, Suite 150, Aliso Viejo, CA 92656 USA 5 of 8 t&m@meas-spec.com
Operating Manual
TM TM
Cable Routing
The model 4623 accelerometer incorporates a FEP jacketed cable with an integral shield. The cable assembly should be properly secured at regular intervals during testing. It is recommended to use clamps, wax, or tape to secure the cable to minimize cable motion that can add noise to the output signal. The initial attachment should be within two to three inches of the accelerometer with some slack in the cable to prevent tension at the connector joint
Avoid routing cables near high-voltage wires and also ground the shield at the signal conditioner to minimize ground loops.
Measurement Specialties, Inc. www.meas-spec.com +1 949-716-5377 32 Journey, Suite 150, Aliso Viejo, CA 92656 USA 6 of 8 t&m@meas-spec.com
Operating Manual
TM TM
FULL SCALE
RATING
(g-pk)
SENSITIVITY
(mV/g)
±5% AMPL
PASSBAND
(Hz)
PASSBAND
NOISE
(µVrms)
SPECTRAL
NOISE
(µg-rms/√Hz)
DYNAMIC
RANGE
(dB)
2
1000
150
500
35
72 5 400
150
500
38
76
10
200
200
450
75
76
25
80
400
550
219
75
50
40
600
450
316
74
100
20
1000
450
516
74
Noise Floor Specifications
The model 4623 accelerometer incorporates a LP filtered output for a high output signal. The noise specifications for this accelerometer are detailed in table below.
Measurement Specialties, Inc. www.meas-spec.com +1 949-716-5377 32 Journey, Suite 150, Aliso Viejo, CA 92656 USA 7 of 8 t&m@meas-spec.com
Operating Manual
TM TM
Typical Phase Response
-40
-35
-30
-25
-20
-15
-10
-5
0
5
10
15
20
25
30
35
40
10 100 1000 10000
Frequency (Hz)
Phase (degrees)
2g Range 10g Range 30g Range 50g Range 100g Range 200g Range
Typical Frequency Response
-40
-35
-30
-25
-20
-15
-10
-5
0
5
10
15
20
25
30
35
40
1 10 100 1000 10000
Frequency (Hz)
Sensitivity Deviation (%)
2g Range 5g Range 10g Range 25g Range 50g Range 100g-500g Range
Frequency Response & Phase Deviation Curves
The typical frequency response and phase deviation curves for the model 4623 accelerometer are illustrated below.
Measurement Specialties, Inc. www.meas-spec.com +1 949-716-5377 32 Journey, Suite 150, Aliso Viejo, CA 92656 USA 8 of 8 t&m@meas-spec.com
Loading...