Your new Measurement Computing product comes with a fantastic extra —
Management committed to your satisfaction!
Thank you for choosing a Measurement Computing product—and congratulations! You own the finest, and you can now enjoy
the protection of the most comprehensive warranties and unmatched phone tech support. It’s the embodiment of our mission:
To provide data acquisition hardware and software that will save time and save money.
Simple installations minimize the time between setting up your system and actually making measurements. We offer quick and
simple access to outstanding live FREE technical support to help integrate MCC products into a DAQ system.
Limited Lifetime Warranty: Most MCC products are covered by a limited lifetime warranty against defects in materials or
workmanship for the life of the product, to the original purchaser, unless otherwise noted. Any products found to be defective in
material or workmanship will be repaired, replaced with same or similar device, or refunded at MCC’s discretion. For specific
information, please refer to the terms and conditions of sale.
Harsh Environment Program: Any Measurement Computing product that is damaged due to misuse, or any reason, may be
eligible for replacement with the same or similar device for 50% of the current list price. I/O boards face some harsh
environments, some harsher than the boards are designed to withstand. Contact MCC to determine your product’s eligibility for
this program.
30 Day Money-Back Guarantee: Any Measurement Computing Corporation product may be returned within 30 days of
purchase for a full refund of the price paid for the product being returned. If you are not satisfied, or chose the wrong product by
mistake, you do not have to keep it.
These warranties are in lieu of all other warranties, expressed or implied, including any implied warranty of merchantability or
fitness for a particular application. The remedies provided herein are the buyer’s sole and exclusive remedies. Neither
Measurement Computing Corporation, nor its employees shall be liable for any direct or indirect, special, incidental or
consequential damage arising from the use of its products, even if Measurement Computing Corporation has been notified in
advance of the possibility of such damages.
Trademark and Copyright Information
Measurement Computing Corporation, InstaCal, Universal Library, and the Measurement Computing logo are either trademarks
or registered trademarks of Measurement Computing Corporation. Refer to the Copyrights & Trademarks section on
mccdaq.com/legal for more information about Measurement Computing trademarks. Other product and company names
retrieval system, or transmitted, in any form by any means, electronic, mechanical, by photocopying, recording, or otherwise
without the prior written permission of Measurement Computing Corporation.
Notice
Measurement Computing Corporation does not authorize any Measurement Computing Corporation product for use
in life support systems and/or devices without prior written consent from Measurement Computing Corporation.
Life support devices/systems are devices or systems that, a) are intended for surgical implantation into the body, or
b) support or sustain life and whose failure to perform can be reasonably expected to result in injury. Measurement
Computing Corporation products are not designed with the components required, and are not subject to the testing
required to ensure a level of reliability suitable for the treatment and diagnosis of people.
Table of Contents
Preface
About this User's Guide ....................................................................................................................... 5
What you will learn from this user's guide ......................................................................................................... 5
Conventions in this user's guide ......................................................................................................................... 5
Where to find more information ......................................................................................................................... 5
Chapter 1
Introducing the USB-1608FS-Plus ....................................................................................................... 6
Installing the USB-1608FS-Plus ........................................................................................................... 7
What comes with your shipment? ....................................................................................................................... 7
Installing the software ........................................................................................................................................ 7
Installing the hardware ....................................................................................................................................... 7
Calibrating the hardware..................................................................................................................................... 8
Analog input modes ............................................................................................................................................ 9
USB connector .................................................................................................................................................................10
LED .................................................................................................................................................................................10
Signal connections ............................................................................................................................................ 11
Analog input ....................................................................................................................................................................11
Digital I/O ........................................................................................................................................................................12
Power output ....................................................................................................................................................................13
Analog input ..................................................................................................................................................... 17
Analog input DC voltage measurement accuracy ............................................................................................................17
Digital input/output........................................................................................................................................... 18
Power ................................................................................................................................................................ 21
General ............................................................................................................................................................. 21
Screw terminal connector and pinout ............................................................................................................... 22
Declaration of Conformity .................................................................................................................. 23
4
About this User's Guide
What you will learn from this user's guide
This user's guide describes the Measurement Computing USB-1608FS-Plus data acquisition device and lists
device specifications.
Conventions in this user's guide
For more information
Text presented in a box signifies additional information and helpful hints related to the subject matter you are
reading.
Caution! Shaded caution statements present information to help you avoid injuring yourself and others,
damaging your hardware, or losing your data.
bold text Bold text is used for the names of objects on a screen, such as buttons, text boxes, and check boxes.
italic text Italic text is used for the names of manuals and help topic titles, and to emphasize a word or phrase.
Preface
Where to find more information
Additional information about the USB-1608FS-Plus is available on our website at www.mccdaq.com. You can
also contact Measurement Computing Corporation by phone, fax, or email with specific questions.
Knowledgebase: kb.mccdaq.com
Tech support form: www.mccdaq.com/support/support_form.aspx
Email: techsupport@mccdaq.com
Phone: 508-946-5100 and follow the instructions for reaching Tech Support
For international customers, contact your local distributor. Refer to the International Distributors section on our
web site at www.mccdaq.com/International.
5
Chapter 1
Introducing the USB-1608FS-Plus
The USB-1608FS-Plus is an analog input and digital I/O data acquisition device providing the following
features:
Eight 16-bit single-ended (SE) analog input channels
Each input channel has a dedicated A/D converter for simultaneous sampling.
Software-selectable analog input ranges of ±10 V, ±5 V, ±2 V, and ±1 V
Eight individually configurable digital I/O channels
One 32-bit event counter
One external digital trigger input
Bidirectional external clock for synchronous operation with more than one device.
Screw terminals for field wiring connections
The device is powered by the +5V USB supply from the computer, requiring no external power.
The USB-1608FS-Plus is compatible with both USB 1.1 and USB 2.0 ports. The speed of the device may be
limited when using a USB 1.1 port due to the difference in transfer rates on the USB 1.1 versions of the
protocol (low-speed and full-speed).
Functional block diagram
USB-1608FS-Plus functions are illustrated in the block diagram shown here.
Figure 1. Functional block diagram
6
Installing the USB-1608FS-Plus
What comes with your shipment?
Verify that the following hardware components are included in the shipment:
Hardware
USB-1608FS-Plus
USB cable
Software
MCC DAQ CD
Documentation
MCC DAQ Quick Start
The MCC DAQ Quick Start booklet provides an overview of the MCC DAQ software you received with
the device, and includes information about installing the software. Please read this booklet completely
before installing any software or hardware.
DAQami Quick Start
The DAQami Quick Start insert provides information about the DAQami advanced data logging
application, including a quick start procedure and quick reference guide.
Chapter 2
Unpacking
As with any electronic device, you should take care while handling to avoid damage from static
electricity. Before removing the device from its packaging, ground yourself using a wrist strap or by simply
touching the computer chassis or other grounded object to eliminate any stored static charge.
Contact us immediately if any components are missing or damaged.
Installing the software
Refer to the MCC DAQ Quick Start for instructions on installing the software on the MCC DAQ CD. Refer to
the device product page on the Measurement Computing website for information about the included and
optional software supported by the USB-1608FS-Plus.
Install the software before you install your device
The driver needed to run the USB-1608FS-Plus is installed with the software. Therefore, you need to install the
software package you plan to use before you install the hardware.
For operation on a Windows operating system, we recommend that you run Windows Update to update your
operating system with the latest USB drivers.
Installing the hardware
To connect the USB-1608FS-Plus to your system, connect the USB cable to an available USB port on the
computer or to an external USB hub connected to the computer. Connect the other end of the USB cable to the
USB connector on the device. No external power is required.
When connected for the first time, a Found New Hardware dialog opens when the operating system detects the
device. When the dialog closes, the installation is complete. The LED on the USB-1608FS-Plus turns on after
the device is successfully installed.
7
USB-1608FS-Plus User's Guide Installing the USB-1608FS-Plus
If the LED turns off
If communication is lost between the device and the computer, the device LED turns off. To restore
communication, disconnect the USB cable from the computer and then reconnect it. This should restore
communication, and the LED should turn on.
Calibrating the hardware
The Measurement Computing Manufacturing Test department performs the initial factory calibration. Return
the device to Measurement Computing Corporation when calibration is required. The recommended calibration
interval is one year.
The USB-1608FS-Plus does not support field calibration.
8
Loading...
+ 16 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.