Measurement DBK201 User Manual

DBK201 P4-to-P1/P2/P3 Adapter Board
For Analog I/O, Digital I/O, & Pulse/Frequency
Overview …… 1 Connections …… 2 DBK201 Dimensional Drawing …… 3
Note:
DBK201 connects to a P4 connector via cable and provides P1, P2, and P3 connectors.
This product is not used for LogBook applications.
Reference Notes:
Refer to the DBK Basics section in regard to calculating system power requirements. Chapter 2 includes pinouts for P1, P2, P3, and P4.
Refer to the pinouts that are applicable to your system, as needed.
DBK201, P4-to-P1/P2/P3 Adapter
Overview
For a quick comparison of all DBK200 Series boards, refer to the DBK200 Series Matrix
which directly precedes this section.
Refer to the DaqBoard/2000 Series and cPCI DaqBoard/2000c Series User’s Manual
(p/n 1033-0901) or the DaqBook/2000 Series User’s Manual (p/n 1103-0901) for information pertaining to those products, as needed.
DaqBoard/2000 Series and cPCI DaqBoard/2000c Series boards communicate [external from the host PC] through a 100-pin P4 connector. The DBK201 P4-to-P1/P2/P3 adapter provides DB37 P1, P2, and P3 connectors. P1 is used for ANALOG I/O, P2 is used for DIGITAL I/O, and P3 is used for Pulse/Frequency (Digital and Counter/Timer) I/O.
Note: The P1, P2, and P3 connectors discussed in association with DaqBook/2000 Series devices,
DaqBoard/2000 Series boards, and cPCI DaqBoard/2000c Series boards are subset connectors of the 100-pin P4 connector that is located on those boards. Chapter 2 includes pinouts for P1, P2, P3, and P4.
DBK Option Cards and Modules 989494 DBK201, pg. 1
Connections
The following illustration and the actual board silkscreen are the only references you should need to make proper connections.
CAUTION
Turn off power to the host PC and externally connected equipment prior to connecting cables or signal lines to the DBK. Electric shock or damage to equipment can result even under low-voltage conditions. Take ESD precautions (packaging, proper handling, grounded wrist strap, etc.)
Use care to avoid touching board surfaces and onboard components. Only handle boards by their edges (or ORBs, if applicable). Ensure boards do not come into contact with foreign elements such as oils, water, and industrial particulate.
Do not confuse connectors. Ensure that you only connect P1 I/Os to P1, P2 I/Os to P2, and P3 I/Os to P3. Improper connection may result in equipment damage.
Be sure to align the P4 orientation indicators () prior to mating the P4 connectors.
Connection tips:
Ensure power is removed from the device(s) to be connected.
Observe ESD precautions when handling boards and making connections.
P1 is used for ANALOG I/O.
P2 is used for DIGITAL I/O.
P3 is used for Pulse/Frequency (Digital and Counter/Timer) I/O.
P4 (100-pin connector) connects to either the DaqBook/2000 Series device’s, DaqBoard/2000
Series board’s or cPCI DaqBoard/2000c Series board’s P4 connector via a CA-195 Cable.
Connects to P4 on the
DaqBook/2000 Series Device DaqBoard/2000 Series Board cPCI DaqBoard/2000c Series Board
DBK201, pg. 2
Making Connections via a DBK201
989494 DBK Option Cards and Modules