Measurement DADP-5037 User Manual

PORT A_0 1 PORT A_2 PORT A_4
PORT A_6
PORT B_ 4 PORT B_ 6 PORT C_ 0 1 PORT C_ 2
PORT C_ 4
PORT C_ 6
PASS_1 25 PASS_3 27 PASS_5 2 PASS_7
PASS_9 PASS_11 PASS_13 PASS_15 PASS_17 PASS_19 PASS_21 PASS_23 PASS_25
P1
2 PORT A_1 4
3 5 7
9 11 13 15
7 19 21 23
9 31 33 35 37 39 41 43 45 47 49
6
8
10
PORT B_1
12
PORT B_3
14
PORT B_5
16
PORT B_7
18
PORT C_1
20
PORT C_3
22
PORT C_5
24
PORT C_7 26 PASS_2 28
PASS_4 30
PASS_6 32
PASS_8 34
PASS_10 36
PASS_12
PASS_14
38
PASS_16
40
PASS_18
42
PASS_20
44
PASS_22
46
PASS_24
48
GND
50
DADP-5037 Connection Guide
U1
+5V Reg.
1 2 3
IN
OUT
GND
PORT A_0 37 PORT A_1 PORT A_2 PORT A_3 PORT A_4 PORT A_5 PORT A_6
PORT A_7
PORT C_0 PORT C_1 PORT C_2 PORT C_3 PORT C_4 PORT C_5 PORT C_6 PORT C_7
GND
36 35 34 33 32 31 30 29 28 27 26 25 24 23 22 21 20
P2
19 n/c 18 n/c 17 n/c
n/c
16
n/c
15
n/c
14
n/c
13
n/c
12
n/c
11
PORT B_0
10
PORT B_1
9
8
7
6
5
4
3
n/c
2
n/c
1
PORT A_0 1 PORT A_2 PORT A_4
PORT A_6
PORT B_ 4
PORT B_ 6 PORT C_ 0 1 PORT C_ 2
PORT C_ 4
PORT C_ 6
PASS_1 25 PASS_3 27 PASS_5 2 PASS_7
PASS_9 PASS_11 PASS_13 PASS_15 PASS_17 PASS_19 PASS_21 PASS_23 PASS_25
P3
2 PORT A_1 3 5 7 9
11 13 15
7
19 21 23
9
31 33 35 37 39 41 43 45 47 49
4
6
8
10
PORT B_1
12
PORT B_3
14
PORT B_5
16
PORT B_7
18
PORT C_1
20
PORT C_3 PORT C_5
22
PORT C_7
24
26 PASS_2
PASS_4
28
PASS_6
30
PASS_8
32
PASS_10
34
PASS_12
36
PASS_14
38
PASS_16
40
PASS_18
42
PASS_20
44
PASS_22
46
PASS_24
48
GND
50
signal conditioning and accessory boards. The DADP-5037 connects the digital I/O bits from the PCI board’s 100-pin I/O connector to those external accessory and signal conditioning boards using 37D I/O-type connectors.
Notes:
# Connector P1 and P3 are wired 1:1, which allows either connector to be used as the
main interface between the PCI board and the DADP-5037. The unused 50-pin connector can be used for applications that require you to monitor the I/O signals of the connector in use. Consult your DAS manual’s I/O connector pin assignment section to verify which signals are available at the connector being monitored.
# Position U1 is reserved for the installation of a voltage regulator
(MCC p/n TN-MC78M05CT). The voltage regulator should only be used with accessory boards that are powered through the 37D connector, such as the SSR-RACK08 board.
The DADP-5037 adapter board allows PCI analog I/O boards to interface and control
DADP-5037 Connector Map.cdr © 2003 Measurement Computing Corporation
C100FF-X
51-100 Cable
P3
P1
DADP-5037
To accessory board’s
37D I/O connector
P2
Document Revision 2
Loading...