Measurement CIO-DUAL422 User Manual

CIO-COM422, CIO-DUAL422, and CIO-COM485 Installation Guide
Standard 9-pin and 25-pin connectors
The CIO-COM422 combines an RS232 and an RS422 interface with a single communications port. RS232 is commonly a 25-pin connector, while RS422 is a 9-pin connector.
The pin assignments shown here conform to the RS232 and RS422 standards.
The CIO-DUAL422 combines a pair of communications ports each with RS422 standard interfaces. Each COM port uses one of the 9-pin connectors shown here.
The CIO-COM485 is equipped with two DB9 connectors for RS485 standard 9-pin connectors and cables. The RS485 standard allows multiple transmitters and receivers on a single communications cable.
The CIO-COM485 facilitates interconnection by providing two connectors wired in parallel to the single communications port. In this manner, standard cables may be used without a "T".
Base Address
Personal computer COM1, 2, 3, or 4 ports are assigned through a combination of base address and interrupt level. Each COM board has one base address switch for each COM chip.
To operate correctly with personal computer COM# software drivers, the guidelines for both address and interrupt level should be adhered to.
CIO-COM422 Protocol Select switch
There are 5 possible protocol selections available through the protocol select switch:
Standard RS232 with
RTS, DTR, and CTS.
RS232 without RTS,
DTR, and CTS.
Current loop. RS422 with RTS and
CTS control signals.
RS422 without RTS
and CTS.
Interrupt Level jumper
Communications software such as the standard COM drivers included with DOS and Windows use interrupt service routines assigned to specific interrupt numbers. Choose the correct interrupt number by setting the jumper on the CIO-COM board.
Different computers require different interrupt settings for COM3: and COM4:. Check with your PC owner's manual for the correct IRQ settings on your computer.
CIO-DUAL422 CTS/RTS Enable jumper
RS422 may be used with or without hardware handshaking. The Clear To Send (CTS) and RTS signal lines may be enabled or disabled by setting a jumper on the CIO-DUAL422.
DS cio-com_dual422_com485.docx
Document Revision 2, September, 2009 Copyright © Measurement Computing Corporation