Your new Measurement Computing product comes with a fantastic extra —
Management committed to your satisfaction!
Thank you for choosing a Measurement Computing product—and congratulations! You own the finest, and you can now enjoy
the protection of the most comprehensive warranties and unmatched phone tech support. It’s the embodiment of our mission:
To provide data acquisition hardware and software that will save time and save money.
Simple installations minimize the time between setting up your system and actually making measurements. We offer quick and
simple access to outstanding live FREE technical support to help integrate MCC products into a DAQ system.
Limited Lifetime Warranty: Most MCC products are covered by a limited lifetime warranty against defects in materials or
workmanship for the life of the product, to the original purchaser, unless otherwise noted. Any products found to be defective in
material or workmanship will be repaired, replaced with same or similar device, or refunded at MCC’s discretion. For specific
information, please refer to the terms and conditions of sale.
Harsh Environment Program: Any Measurement Computing product that is damaged due to misuse, or any reason, may be
eligible for replacement with the same or similar device for 50% of the current list price. I/O boards face some harsh
environments, some harsher than the boards are designed to withstand. Contact MCC to determine your product’s eligibility for
this program.
30 Day Money-Back Guarantee: Any Measurement Computing Corporation product may be returned within 30 days of
purchase for a full refund of the price paid for the product being returned. If you are not satisfied, or chose the wrong product by
mistake, you do not have to keep it.
These warranties are in lieu of all other warranties, expressed or implied, including any implied warranty of merchantability or
fitness for a particular application. The remedies provided herein are the buyer’s sole and exclusive remedies. Neither
Measurement Computing Corporation, nor its employees shall be liable for any direct or indirect, special, incidental or
consequential damage arising from the use of its products, even if Measurement Computing Corporation has been notified in
advance of the possibility of such damages.
Trademark and Copyright Information
Measurement Computing Corporation, InstaCal, Universal Library, and the Measurement Computing logo are either trademarks
or registered trademarks of Measurement Computing Corporation. Refer to the Copyrights & Trademarks section on
mccdaq.com/legal for more information about Measurement Computing trademarks. Other product and company names
mentioned herein are trademarks or trade names of their respective companies.
Measurement Computing Corporation does not authorize any Measurement Computing Corporation product for use
in life support systems and/or devices without prior written consent from Measurement Computing Corporation.
Life support devices/systems are devices or systems that, a) are intended for surgical implantation into the body, or
b) support or sustain life and whose failure to perform can be reasonably expected to result in injury. Measurement
Computing Corporation products are not designed with the components required, and are not subject to the testing
required to ensure a level of reliability suitable for the treatment and diagnosis of people.
HM CIO-DIO48.doc
3
Table of Contents
Preface
About this User's Guide .......................................................................................................................6
What you will learn from this user's guide.........................................................................................................6
Conventions in this user's guide.........................................................................................................................6
Where to find more information.........................................................................................................................6
Chapter 1
Introducing the CIO-DIO48...................................................................................................................7
Overview: CIO-DIO48 features .........................................................................................................................7
Unpacking the CIO-DIO48 ................................................................................................................................9
Installing the software ........................................................................................................................................9
Configuring the base address switch..................................................................................................................9
Base address switch.......................................................................................................................................................... 9
Wait state jumper.............................................................................................................. ...............................................10
Installing the CIO-DIO48 .................................................................................................................................11
Connecting the board for I/O operations..........................................................................................................11
Connectors, cables – main I/O connector ........................................................................................................................11
Pinout – main I/O connector............................................................................................................................................12
Field wiring, signal termination, and conditioning..........................................................................................................13
Signal level control...........................................................................................................................................14
Digital I/O Isolation..........................................................................................................................................15
Chapter 4
Programming and Developing Applications....................................................................................16
Digital input / output ........................................................................................................................................17
Power consumption..........................................................................................................................................17
Main connector and pin out..............................................................................................................................17
4
Preface
About this User's Guide
What you will learn from this user's guide
This user's guide explains how to install, configure, and use the CIO-DIO48 board so that you get the most out
of its analog output features. This user's guide also refers you to related documents available on our web site,
and to technical support resources.
Conventions in this user's guide
The following conventions are used in this manual to convey special information:
For more information on …
Text presented in a box signifies additional information and helpful hints related to the subject matter you are
reading.
Caution! Shaded caution statements present information to help you avoid injuring yourself and others,
damaging your hardware, or losing your data.
<#:#> Angle brackets that enclose numbers separated by a colon signify a range of numbers, such as those assigned
to registers, bit settings, etc.
bold text Bold text is used for the names of objects on the screen, such as buttons, text boxes, and check boxes. For
example:
1. Insert the disk or CD and click the OK button.
italic text Italic text is used for the names of manuals and help topic titles, and to emphasize a word or phrase. For
example:
The InstaCal installation procedure is explained in the Quick Start Guide.
Never touch the exposed pins or circuit connections on the board.
Where to find more information
The following electronic documents provide information relevant to the operation of the CIO-DIO48.
MCC's Specifications: CIO-DIO48 (the PDF version of the Specifications chapter in this guide) is available
on our web site at www.mccdaq.com/pdfs/CIO-DIO48.pdf
MCC's Quick Start Guide is available on our web site at
MCC's Guide to Signal Connections is available on our web site at
www.mccdaq.com/signals/signals.pdf
MCC's Universal Library User's Guide is available on our web site at
www.mccdaq.com/PDFmanuals/sm-ul-user-guide.pdf
MCC's Universal Library Function Reference is available on our web site at
www.mccdaq.com/PDFmanuals/sm-ul-functions.pdf
MCC's Universal Library for LabVIEW
www.mccdaq.com/PDFmanuals/SM-UL-LabVIEW.pdf
.
™
User’s Guide is available on our web site at
.
.
.
.
.
CIO-DIO48 User's Guide (this document) is also available on our web site at
www.mccdaq.com/PDFmanuals/CIO-DIO48.pdf
.
5
Chapter 1
Introducing the CIO-DIO48
Overview: CIO-DIO48 features
The CIO-DIO48 has 48 digital I/O connections, and two 82C55 parallel-interface chips.
Each 82C55 chip controls 24 CMOS/TTL-compatible digital I/O pins. You can program each 82C55 as three
8-bit ports, or two 8-bit ports and two 4-bit ports. Each port is programmable for input or output.
All I/O bits are set to input mode (high impedance) on power up and reset. Locations are available for installing
pull-up or pull-down resistors.
All signals pass through a 50-pin connector.
Software features
For information on the features of InstaCal and the other software included with your CIO-DIO48, refer to the
Quick Start Guide that shipped with your device. The Quick Start Guide is also available in PDF at
the software you received with your CIO-DIO48 and information regarding installation of that software. Please
read this booklet completely before installing any software or hardware.
). This booklet supplies a brief description of
Optional components
C50FF-x cable
Signal termination and conditioning accessories
MCC provides signal conditioning and termination products for use with the CIO-DIO48. Refer to Field
wiring, signal termination, and conditioning on page 13 for a complete list of compatible accessory
products.
7
CIO-DIO48 User's Guide Installing the CIO-DIO48
W
A3
X
Unpacking the CIO-DIO48
As with any electronic device, you should take care while handling to avoid damage from static
electricity. Before removing the CIO-DIO48 from its packaging, ground yourself using a wrist strap or by
simply touching the computer chassis or other grounded object to eliminate any stored static charge.
If any components are missing or damaged, notify Measurement Computing Corporation immediately by
phone, fax, or e-mail:
Phone: 508-946-5100 and follow the instructions for reaching Tech Support.
Fax: 508-946-9500 to the attention of Tech Support
Email: techsupport@mccdaq.com
Installing the software
Refer to the Quick Start Guide for instructions on installingthe software on the Measurement Computing Data
Acquisition Software CD. This booklet is available in PDF at www.mccdaq.com/PDFmanuals/DAQ-Software-
Quick-Start.pdf.
Configuring the base address switch
The CIO-DIO48 employs the PC bus for power, communications and data transfer. It draws power from the
PC, monitors the address lines and control signals, responds to its I/O address, and receives and places data on
the eight data lines.
The CIO-DIO48 has one bank of base address-select switches, and one wait-state jumper. Verify their settings
before installing the board in your computer.
Base address switch
The easiest way to set the base address is to let InstaCal show you the correct settings. However, if you are
already familiar with setting ISA base addresses, you may use the base address switch description below to
guide your base address selection.
The base address is the starting location that software writes to when communicating with the CIO-DIO48. A
set of DIP switches is used to set the base address. By placing the switch down, the CIO-DIO48 address decode
logic is instructed to respond to that address bit. A complete address is constructed by calculating the HEX or
decimal number which corresponds to all the address bits the board has been instructed to respond to.
The board is shipped with the base address set to 300 hex (see
system that uses address 300 hex (768 decimal), leave the switches as they were set at the factory.
9876
54
Figure 1
3
). Unless there is already a board in your
HE
S
200
A9
100
A8
80
A7
40
A6
20
A5
10
A4
08
Figure 1. Base address switch
In the default configuration, addresses 9 and 8 are down, and all others are up. Address 9 = 200 hex
(512 decimal), and address 8 = 100 hex (256 decimal). When added together they equal 300 hex (768 decimal).
8
CIO-DIO48 User's Guide Installing the CIO-DIO48
Disregard the numbers printed on the switch
When setting the base address, refer to the numbers printed in white on the printed circuit board.
PC I/O Address Summary
Hex Range Function Hex Range Function
000-00F 8237 DMA #1 2C0-2CF EGA
020-021 8259 PIC #1 2D0-2DF EGA
040-043 8253 TIMER 2E0-2E7 GPIB (AT)
060-063 8255 PPI (XT) 2E8-2EF SERIAL PORT
060-064 8742 CONTROLLER (AT) 2F8-2FF SERIAL PORT
070-071 CMOS RAM & NMI MASK (AT) 300-30F PROTOTYPE CARD
080-08F DMA PAGE REGISTERS 310-31F PROTOTYPE CARD
0A0-0A1 8259 PIC #2 (AT) 320-32F HARD DISK (XT)
0A0-0AF NMI MASK (XT) 378-37F PARALLEL PRINTER
0C0-0DF 8237 #2 (AT) 380-38F SDLC
0F0-0FF 80287 NUMERIC CO-P (AT) 3A0-3AF SDLC
1F0-1FF HARD DISK (AT) 3B0-3BB MDA
200-20F GAME CONTROL 3BC-3BF PARALLEL PRINTER
210-21F EXPANSION UNIT (XT) 3C0-3CF EGA
238-23B BUS MOUSE 3D0-3DF CGA
23C-23F ALT BUS MOUSE 3E8-3EF SERIAL PORT
270-27F PARALLEL PRINTER 3F0-3F7 FLOPPY DISK
2B0-2BF EGA 3F8-3FF SERIAL PORT
You can set the base address switch to any address in the range of 000-3F8. If you are not using IBM
prototyping cards or another board which occupies these addresses, 300-31Fh are also free to use.
Addresses not specifically listed, such as 390-39Fh, are not reserved and may be available. Check your
computer for other boards which may use I/O addresses.
Wait state jumper
The CIO-DIO48 board has a wait state jumper which you can set to enable an on-board wait state generator. A
wait state is an extra delay injected into the processor's clock via the bus. This delay slows down the processor
when the processor addresses the CIO-DIO48 board, so that signals from slow devices (chips) are valid.
The jumper is shown in configured for OFF (wait state is disabled). Figure 2
O
O
F
N
F
WAIT
STATE
Figure 2. Wait state jumper
The wait state generator is only active when the CIO-DIO48 is being accessed. Your PC will not be slowed
down in general by using the wait state.
Because all PC expansion board buses are slowed to either 8 MHz or 10 MHz, the wait state generally is not
required. If you experience sporadic failures, try enabling the wait state generator.
9
CIO-DIO48 User's Guide Installing the CIO-DIO48
Installing the CIO-DIO48
After you configure the base address, you can install the CIO-DIO48 into your computer. Follow the steps
below.
Install the MCC DAQ software before you install your board
The driver needed to run your board is installed with the MCC DAQ software. Therefore, you need to install
the MCC DAQ software before you install your board. Refer to the Quick Start Guide for instructions on
installing the software.
1.
Turn your computer off, open it up, and insert your board into an available ISA slot.
2.
Close your computer and turn it on.
3.
To test your installation and configure your board, run the InstaCal utility you installed in the previous
section. Refer to the Quick Start Guide that came with your board www.mccdaq.com/PDFmanuals/DAQ-
Software-Quick-Start.pdf for information on how to initially set up and load InstaCal.
Connecting the board for I/O operations
Connectors, cables – main I/O connector
The table below lists the board connector, applicable cables, and compatible accessory products.
Board connector, cables, and accessory equipment
Connector type 50-pin shrouded male header (P1)
Compatible cables C50FF-x
Compatible accessory products
The CIO-DIO48 connector (P1) is a 50-pin male shrouded header connector that is accessible through the
PC/AT expansion bracket.
FIRSTPORTC Bit 0 48
GND 50
FIRSTPORTC Bit 2 46
FIRSTPORTC Bit 4 44
FIRSTPORTC Bit 6 42
FIRSTPORTB Bit 0 40
FIRSTPORTB Bit 2 38
FIRSTPORTB Bit 4 36
FIRSTPORTB Bit 6 34
FIRSTPORTA Bit 0 32
FIRSTPORTA Bit 2 30
FIRSTPORTA Bit 4 28
FIRSTPORTA Bit 6 26
SECONDPOR TC Bit 0 24
SECONDPOR TC Bit 2 22
SECONDPOR TC Bit 4 20
SECONDPOR TC Bit 6 18
SECONDPOR TB Bit 0 16
SECONDPOR TB Bit 2 14
SECONDPOR TB Bit 4 12
SECONDPOR TB Bit 6 10
SECONDPORT A Bit 08
SECONDPORT A Bit 26
SECONDPORT A Bit 44
SECONDPORT A Bit 62
49+5V
47FIRSTPORTC Bit 1
45FIRSTPORTC Bit 3
43FIRSTPORTC Bit 5
41FIRSTPORTC Bit 7
39FIRSTPORTB Bit 1
37FIRSTPORTB Bit 3
35FIRSTPORTB Bit 5
33FIRSTPORTB Bit 7
31FIRSTPORTA Bit 1
29FIRSTPORTA Bit 3
27FIRSTPORTA Bit 5
25FIRSTPORTA Bit 7
23SECONDPORTC Bit 1
21SECONDPORTC Bit 3
19SECONDPORTC Bit 5
17SECONDPORTC Bit 7
15SECONDPORTB Bit 1
13SECONDPORTB Bit 3
11SECONDPORTB Bit 5
9SECONDPOR TB Bit 7
7SECONDPORTA Bit 1
5SECONDPORTA Bit 3
3SECONDPORTA Bit 5
1SECONDPORTA Bit 7
Figure 3. I/O connector pin-out
All the digital inputs and outputs are TTL. Under normal operating conditions, the voltages on the I/O pins
range from near 0 volts for the low state, to near 5 volts for the high state. The voltages and currents of external
devices usually exceed these values. Because of this, external relays are usually employed to handle higher
current and voltage loads.
In addition to load matching, digital signal sources often need to be filtered or "de-bounced". Refer to the Guide to Signal Connections for information on digital interfacing. This document is available at
www.mccdaq.com/signals/signals.pdf
Cabling
2
50
1
49
50-pin Female
IDC Connector
The red stripe
identifies pi n # 1
Figure 4. C50FF-x cable
2
50
1
49
50-pin Female
IDC connector
11
CIO-DIO48 User's Guide Installing the CIO-DIO48
Field wiring, signal termination, and conditioning
You can use the following cabling, screw termination, and signal conditioning products with the CIO-DIO48.
CIO-TERM100 – 100-pin screw terminal board (daisy-chained 50-pin IDC connectors).
CIO-SPADE50 – 16" X 4" termination panel which mates with both 37-pin and 50-pin connectors.
CIO-MINI50 – 50-pin screw terminal board.
SSR-RACK24 – 24-channel, solid-state relay mounting rack for digital signal conditioning.
SSR-RACK48 – 48-channel, solid-state relay mounting rack with quad-format modules.
CIO-ERB24 – 24 Form C relays, 6 Amp relay accessory board for digital signal conditioning.
CIO-ERB48 – 48 Form C relays, 6 Amp, relay, 50-pin accessory board for digital signal conditioning.
Information on signal connections
General information regarding signal connection and configuration is available in the Guide to Signal
Connections. This document is available on our web site at www.mccdaq.com/signals/signals.pdf.
12
s
Chapter 3
Functional Details
Signal level control
The digital I/O bits on the CIO-DIO48 are 8255 CMOS TTL. The 82C55 digital I/O chip initializes all ports as
inputs on power- up and reset. A TTL input is a high impedance input. If you connect another TTL input device
to the 82C55 it could be turned ON or OFF every time the 82C55 is reset.
All I/O bits are set to input mode on power up and reset. If you are using the board to control items that must be
OFF on reset, install pull-down resistors. The CIO-DIO48 has open locations where you can install Single
Inline Packages (SIP) resistor networks in either pull-up or pull-down configurations.
You can install pull-up and pull-down resistor SIP packs at each port. The positions are labeled
RN1 through
RN6 on the board. When installed, the SIP establishes either a high or low logic level at each of the I/O lines on
the port.
To safeguard against unwanted signal levels, the devices being controlled by the CIO-DIO48 board should be
tied low or high as required by a 2.2K Ω resistor. In a 2.2K eight-resistor SIP pack, one side of all of the
resistors is connected to a single common point and brought out to a pin. The common line, usually marked
with a dot or line, is at one end of the SIP. The remaining resistor ends are brought out to the other eight pins
(refer to Figure 5).
2.2KOhm SIP
Dot indicates the
common line
(LO or HI)
I/O Line
Figure 5. Eight-resistor SIP schematic
Figure 6
10 holes in a line. The end labeled
shows a schematic of an SIP installed in both the pull-up and pull-down positions. Each port provides
HI connects to +5V. The end marked LO connects to GND. The eight holes
in the middle (n0 –n7) connect to the eight lines of the Port, A, B or C.
Digital
I/O
Port
n = A, B, or C
+5 VDC
HI
n7
n6
n5
n4
n3
n2
n1
n0
LO
(GND)
2.2 K SIP
COM
Dot
User Connector
Digital I/O Li nes
Digital
I/O
Port
n = A, B, or C
+5 VDC
HI
n7
n6
n5
n4
n3
n2
n1
n0
LO
(GND)
2.2 K SIP
COM
Dot
User Connector
Digital I/O Li nes
2.2 K SIP installed for pull-up
2.2 K SIP installed for pull-down
Figure 6. Pull-up and pull-down resistor SIPs schematic
13
CIO-DIO48 User's Guide Functional Details
To pull-up lines, orient the SIP with the common pin (dot) toward the HI end; to pull-down, install the resistor
with the common pin in the
LO hole.
When installing pull-up and pull-down resistor SIP packs, we recommend using 2.2K, eight-resistor Single
Inline Packages (MCC part number SP-K2.29C). Use a different value only if necessary.
Unconnected inputs float
Unconnected inputs typically float high, but not reliably. If you are using a CIO-DIO48 for input and have
unconnected inputs, ignore the data from those lines. You do not have to terminate input lines. Unconnected
lines will not affect the performance of connected lines. Mask out any unconnected bits in software.
Digital I/O Isolation
To provide external signal conditioning and isolation, you can connect the CIO-DIO48 to a CIO-ERB24 or
SSR-RACK24. The CIO-ERB24 provides 24 Form C electromechanical relays. The SSR-RACK24 is a
mounting rack for 24 solid-state relays.
The CIO-DIO48 provides digital I/O in groups of 48-bits. You can configure the CIO-ERB24 relay output
board and SSR-RACK24 I/O module rack in a daisy chain configuration to use all of the digital I/O bits
provided by the CIO-DIO48 board. An example of this configuration scheme is shown below.
CIO-DIO48
IN
CIO-ERB24
or
SSR-RACK24
CIO-ERB24
or
SSR-RACK24
Figure 7. CIO-DIO48 to CIO-ERB24 or SSR-RACK24 daisy chain
OUT
IN
OUT
The 24 digital I/O bits on pins 25 to 48 (base address +0 through +2) control the first relay board. The
24 digital I/O bits on pins 1 to 24 control the second relay/SSR board on the daisy chain.
Use the C50FF-x cable for interconnections. You can also use SSR-RACK48 or the CIO-ERB48 series relay
boards.
14
Chapter 4
Programming and Developing Applications
After following the installation instructions in Chapter 2, your board should now be installed and ready for use.
In general there may be no correspondence among registers for different boards. Software written at the register
level for other models will not function correctly with your board.
Programming languages
Measurement Computing's Universal Library provides access to board functions from a variety of Windows
programming languages. If you are planning to write programs, or would like to run the example programs for
Visual Basic
www.mccdaq.com/PDFmanuals/sm-ul-user-guide.pdf
Packaged applications programs
Many packaged application programs now have drivers for your board. If the package you own does not have
drivers for your board, please fax or e-mail the package name and the revision number from the install disks.
We will research the package for you and advise how to obtain dr ivers.
or any other language, refer to the Universal Library User's Guide (available on our web site at
).
Some application drivers are included with the Universal Library package, but not with the application package.
If you have purchased an application package directly from the software vendor, you may need to purchase our
Universal Library and drivers. Please contact us by phone, fax or e-mail:
Phone: 508-946-5100 and follow the instructions for reaching Tech Support.
Fax: 508-946-9500 to the attention of Tech Support
Email: techsupport@mccdaq.com
Register-level programming
You should use the Universal Library or one of the packaged application programs mentioned above to control
your board. Only experienced programmers should try register-level programming.
If you need to program at the register level in your application, refer to the Register Map for the CIO-DIO48, CIO-DIO48H, CIO-DIO96, and CIO-DIO192. This document is available on our website at
Typical for 25 °C unless otherwise specified.
Specifications in italic text are guaranteed by design.
Digital input / output
Table 1. DIO specifications
Digital type 82C55
Configuration 4 banks of 8, 4 banks of 4, programmable by bank as input or output
Number of channels 48 I/O
Output high 3.0 volts min @ -2.5 mA
Output low 0.4 volts max @ 2.5 mA
Input high 2.0 volts min, 5.5 volts absolute max
Input low 0.8 volts max, -0.5 volts absolute min
Power up / reset state Input mode (high impedance)
Miscellaneous Locations provided for installation of pull-up or pull-down resistors.
Chapter 5
Power consumption
Table 2. Power consumption specifications
+5V 150 mA typical, 195 mA max
Environmental
Table 3. Environmental specifications
Operating temperature range 0 to 50 °C
Storage temperature range -40 to +100 °C
Humidity 0 to 90% non-condensing
Main connector and pin out
Table 4. Connector specifications
Connector type 50-pin shrouded male header
Compatible cables C50FF-x
Compatible accessory products
with the C50FF-x
50 GND 49 +5V
48 FIRSTPORTC Bit 0 47 FIRSTPORTC Bit 1
46 FIRSTPORTC Bit 2 45 FIRSTPORTC Bit 3
44 FIRSTPORTC Bit 4 43 FIRSTPORTC Bit 5
42 FIRSTPORTC Bit 6 41 FIRSTPORTC Bit 7
40 FIRSTPORTB Bit 0 39 FIRSTPORTB Bit 1
38 FIRSTPORTB Bit 2 37 FIRSTPORTB Bit 3
36 FIRSTPORTB Bit 4 35 FIRSTPORTB Bit 5
34 FIRSTPORTB Bit 6 33 FIRSTPORTB Bit 7
32 FIRSTPORTA Bit 0 31 FIRSTPORTA Bit 1
30 FIRSTPORTA Bit 2 29 FIRSTPORTA Bit 3
28 FIRSTPORTA Bit 4 27 FIRSTPORTA Bit 5
26 FIRSTPORTA Bit 6 25 FIRSTPORTA Bit 7
24 SECONDPORTC Bit 0 23 SECONDPORTC Bit 1
22 SECONDPORTC Bit 2 21 SECONDPORTC Bit 3
20 SECONDPORTC Bit 4 19 SECONDPORTC Bit 5
18 SECONDPORTC Bit 6 17 SECONDPORTC Bit 7
16 SECONDPORTB Bit 0 15 SECONDPORTB Bit 1
14 SECONDPORTB Bit 2 13 SECONDPORTB Bit 3
12 SECONDPORTB Bit 4 11 SECONDPORTB Bit 5
10 SECONDPORTB Bit 6 9 SECONDPORTB Bit 7
8 SECONDPORTA Bit 0 7 SECONDPORTA Bit 1
6 SECONDPORTA Bit 2 5 SECONDPORTA Bit 3
4 SECONDPORTA Bit 4 3 SECONDPORTA Bit 5
2 SECONDPORTA Bit 6 1 SECONDPORTA Bit 7
17
Declaration of Conformity
Manufacturer: Measurement Computing Corporation
Address: 10 Commerce Way
Suite 1008
Norton, MA 02766
USA
Category: Electrical equipment for measurement, control and laboratory use.
Measurement Computing Corporation declares under sole responsibility that the product
CIO-DIO48
to which this declaration relates is in conformity with the relevant prov isions of the following standards or
other documents:
EU EMC Directive 89/336/EEC: Electromagnetic Compatibility, EN55022 (1987), EN50082-1
Emissions: Group 1, Class B
EN55022 (1987): Radiated and Conducted emissions.
Immunity: EN50082-1
IEC 801-2 (1987): Electrostatic Discharge immunity, Criteria B.
IEC 801-3 (1984): Radiated Electromagnetic Field immunity Criteria A.
IEC 801-4 (1988): Electric Fast Transient Burst immunity Criteria B.
Declaration of Conformity based on tests conducted by Chomerics Test Services, Woburn, MA 01801, USA in
December, 1995. Test records are outlined in Chomerics Test Report #EMI0168B.95.
We hereby declare that the equipment specified conforms to the above Directives and Standards.
Carl Haapaoja, Director of Quality Assurance
Measurement Computing Corporation
10 Commerce Way
Suite 1008
Norton, Massachusetts 02766
(508) 946-5100
Fax: (508) 946-9500
E-mail: info@mccdaq.com
www.mccdaq.com
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.