Mean Well TS-400-112, TS-400-124, TS-400-148, TS-400-212, TS-400-224 Service Manual

...
Page 1
SPECIFICATION
MODEL NO.
RATED POWER 400W
MAXIMUM OUTPUT POWER
AC VO LTAG E
OUTPUT
INPUT
BATTERY INPUT PROTECTION
OUTPUT PROTECTION
FUNCTION
ENVIRONMENT
SAFETY & EMC
OTHERS
NOTE
FREQUENCY
WAVEFORM
AC REGULATION
FRONT PANELINDICATOR Operation status ; Green : normal, Orange(flashing) : remote control OFF, Red : abnormal
BAT. VOLTAGE 12V12V
VOLTAGE RANGE (Typ.) Note.3 DC CURRENT (Typ.)
NO LOAD CURRENT DRAW (Typ.) OFF MODE CURRENT DRAW 1mA
EFFICIENCY (Typ.) Note.1
BATTERY TYPES
FUSE
BAT. LOWALARM
BAT. LOW SHUTDOWN
BAT. POLARITY
OVER TEMPERATURE
OUTPUT SHORT
OVER LOAD (Typ.)
GFCI PROCTECTION
REMOTE CONTROL
WORKING TEMP. WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
VIBRATION
SAFETY STANDARDS WITHSTAND VOLTAGE
ISOLATION RESISTANCE EMC EMISSION
EMC IMMUNITY
MTBF
DIMENSION
PACKING
1.Efficiency is tested by 300W, linear load at 13V/26V/52V input voltage.
2.AC regulation and THD are tested by 400W, linear load at 13V/26V/52V input voltage.
3.The tolerance of each voltage value by models is:112/212 0.5V;124/224 1V;148/248 2V.
4.All parameters not specified above are measured at rated load, 25 of ambient temperature and set to factory setting.
5.The ambient temperature derating of 3.5 /1000m with fanless models and of 5 /1000m with fan models for operating altitude higher than 2000m(6500ft).℃℃
400W True Sine Wave DC-AC Power Inverter
Features :
True sine wave output (THD<3%)High surge power up to 800WHigh efficiency up to 88.5%Thermostatically controlled cooling fanBuilt-in remote ON-OFF controlFront panel indicator for operation statusPower ON-OFF switchProtections: Bat. low alarm / Bat. low shutdown / Over voltage / Over temp.
/ Output short / Input reverse polarity / Overload
Application : Home appliance, power tools, office and portable
equipment, vehicle and yacht ...etc.
3 years warranty
TS-400-112 TS-400-124 TS-400-148 TS-400-212 TS-400-224 TS-400-248
= A, F = B, C, D
460W for 180 sec. / 600W for 10 sec. / surge power 800W for 30 cycles(typ.)
Factory setting set at 110VAC
100 / 110 / 115 / 120VAC selectable by setting button S.W
60 0.1Hz 50/60Hz selectable by setting button±
Note.2
True sine wave (THD<3%)
Note.2
±3.0% at rated input voltage
24V 48V 24V 48V
10.5 ~ 15VDC 40A
1.25A
84.5%
Open & sealed LeadAcid
40A*2
11.3 4%±
10.5 4%±
By internal fuse open 85 5℃± ℃
Protection type : Shut down o/p voltage, re-power on to recover
Protection type : Shut down o/p voltage, re-power on to recover
105 ~ 115% load for 180 sec., 115% ~ 150% load for 10 sec.
Protection type : Shut down o/p voltage, re-power on to recover
Optional (Only type F) None
Open : Normal work ; Short : Remote off
-10 ~ +40 @ 100% load ; +60 @ 50% load
20% ~ 90% RH non-condensing
-30 ~ +70 / -22 ~ +158 F, 10 ~ 95% RH non-condensing
10 ~ 500Hz, 3G 10min./1cycle, 60min. each along X, Y, Z axes
EAC TP TC 004 approved, Design refer to
Bat. I/P -AC O/P:3.0KVAC AC O/P - FG:1.5KVAC
Bat. I/P-AC O/P,AC O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
Compliance to FCC classA Compliance to EAC TPTC 020
104.7K hrs min. MIL-HDBK-217F (25 )
205*158*67mm (L*W*H)
1.73Kg; 6pcs/11.4Kg/1.55CUFT
21 ~ 30VDC
20A
0.63A
86%
75 5℃± ℃
o
, EAC TP TC 020
→± →± →±
10A
0.32A
87%
20A*140A*1
70 5℃± ℃
U 458L
TS-400 series
13
E
TPTC004
Factory setting set at 230VAC
200 / 220 / 230 / 240VAC selectable by setting button S.W
50 0.1Hz 50/60Hz selectable by setting button±
10.5 ~ 15VDC
40A
1.25A
86%
40A*2 40A*1 20A*1
11.3 4%±
10.5 4%± 21 4%± 42 4%±42 4%±21 4%±
85 5℃± ℃
; by internal RTH1 detect power transistor
IEC62368-1 CB, EAC TPTC 004 approved
Compliance to EN55032 class A, 72/ 245/ CEE, 95/ 54/ CE, E-Mark, EAC TP TC 020
Compliance to EN61000-4-2,3,8, EAC TPTC 020
20A
0.63A
87.5%
22.5 4%± 45 4%±45 4%±22.5 4%±
75 5℃± ℃
File Name:TS-400-SPEC 2020-04-01
IEC62368-1
(for 212/224/248 only)
10A
0.32A
88.5%
70 5℃± ℃
Page 2
400W True Sine Wave DC-AC Power Inverter
TS-400 series
TS 400 112 A
True sine wave inverter
O/P Wattage:400W
AC Output Socket (optional)
MODEL NO. TS-400-212TS-400-112 TS-400-224TS-400-124 TS-400-248TS-400-148
Socket type
Country
Certificate
TYPE-A
Standard Optional
USA GFCI
TYPE-F
Mechanical Specification
R.C Connector : JST B-XH or equivalent
Open
Normal work
Short
Remote off
25.32
Unit:mm
Output:
100
12:12VDC 24:24VDCBat. Voltage:
48:48VDC
1:110VAC
A :TYPE B :TYPE C :TYPE D :TYPE F :TYPE
A
OUTLET
B
OUTLET
C
OUTLET
D
OUTLET
F
OUTLET
2:230VAC
TYPE-B
Standard Optional Optional
EUROPE
13 13 13
EEE
TYPE-C
AUSTRALIA
TYPE-D
U.K
Derating Curve
R.C
Ground
_
_
_
Will DamageThe Unit. Reverse Polarity
11
8.9
18
9
7
Air flow
direction
Chassis
OFF
ON
10.7
67
12
42.5
120
205
80
60
50
40
LOAD (%)
20
-10 10 20 30 40 50 60 70
0
ENVIRONMENT TEMPERATURE ( )
AC OUTPUT
Type-A
AC OUTPUT
(HORIZONTAL)
Status
Setting
Status
147
158
Setting
Type-B
File Name:TS-400-SPEC 2020-04-01
Loading...