60WAC-DC High Reliability Slim Wall-mountedAdaptor
(for 5V) (for 9~48V)
SGA60E series
■ Features ■ Applications
Ultra slim
Universal AC input / Full range
2 pole EURO plug
No load power consumption < 0.075W for 5~7.5V
<0.15W for 9 ~48V
Consumer electronic devices
Telecommunication devices
Office facilities
Industrial equipments
Energy efficiency Level ( except 5V for Level )ⅥⅤ
Comply with EU ErP and 9~48V meet CoC version 5
Class power (without earth pin) Ⅱ
Protections: Short circuit / Overload / Over voltage
Fully enclosed plastic case
Pass LPS
LED indicator for power on
3 years warranty
■ Description
SGA60E is a 60W ultra slim wall-mounted style single-output green adaptor series, which is compact and
convenient for carry. SGA60E is a class power unit (without FG) equipped with the standard 2-Pole Ⅱ
European plug, accepting the input range from 90VAC to 264VAC. The whole series provides different
models with output voltages ranging between 5VDC and 48VDC that it can satisfy the demands for various
types of consumer electronic devices.
With the efficiency up to 91% and the extremely low no-load power consumption below 0.075W for 5~7.5V,
below 0.15W for 9 ~48V, SGA60E is compliant with EU ErP and 9~48V meet CoC version 5. The supreme
feature allows the adaptor to save the energy when it is under either the operating mode or the standby
mode. The entire series is approved for international safety regulations; moreover, it adopts the 94V-0
flame retardant plastic case that it can effectively prevent users from electric hazards.
■ Model Encoding
-E05SGA P1J60
P1J: Plug for standard model, 2.1 5 5 11mm,ψ× ψ×.
DC plug type
{
Output voltage
European 2 pin AC plug
Output wattage
Series name
C+ tuning fork type
Optional plug type available per request
File Name:SGA60E-SPEC 2015-09-15

SPECIFICATION
ORDER NO.
SAFETY MODEL NO.
DC VO LTAGE
RATED CURRENT
CURRENT RANGE
RATED POWER (max.)
OUTPUT
INPUT
PROTECTION
ENVIRONMENT
SAFETY &
EMC
(Note. 8)
OTHERS
CONNECTOR
NOTE
RIPPLE & NOISE (max.)
VOLTAGE TOLERANCE
LINE REGULATION Note.5
LOAD REGULATION Note.6
SETUP, RISE, HOLD UP TIME
VOLTAGE RANGE
FREQUENCY RANGE
EFFICIENCY (Typ.)
AC CURRENT
INRUSH CURRENT (max.)
LEAKAGE CURRENT(max.)
OVERLOAD
OVER VOLTAGE
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
EMC EMISSION
EMC IMMUNITY
LIFE
MTBF
DIMENSION
PACKING
PLUG
CABLE
1.All parameters are specified at 230VAC input, rated load, 25 70% RH ambient. ℃
2.DC voltage: The output voltage set at point measure by plug terminal & 50% load.
3.Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1uf & 47uf capacitor.
4.Tolerance: includes set up tolerance, line regulation, load regulation.
5.Line regulation is measured from low line to high line at rated load.
6.Load regulation is measured from 10% to 100% rated load.
7.Derating may be needed under low input voltages. Please check the static characteristics for more details.
8.The power supply is considered as an independent unit, but the final equipment still need to re-confirm that the whole system complies with the
EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies.
(as available on http://www.meanwell.com)
60WAC-DC High Reliability Slim Wall-mountedAdaptor
SGA60E05-P1J
SGA60E05 SGA60E09SGA60E07 SGA60E12 SGA60E15 SGA60E18 SGA60E24 SGA60E48
5V 9V7.5V 12V 15V 18V 24V 48V
Note.2
6A 5.5A6A 5A 4A 3.33A 2.5A 1.25A
0 ~ 6A 0 ~ 5.5A0 ~ 6A
30W 49.5W45W 60W 60W 60W 60W 60W
80mVp-p 80mVp-p80mVp-p 80mVp-p 80mVp-p 80mVp-p 100mVp-p 120mVp-p
Note.3
±5.0% ±5.0%±5.0% ±3.0% ±3.0% ±2.0% ±2.0% ±2.0%
Note.4
±1.0% ±1.0%±1.0% ±1.0% ±1.0% ±1.0% ±1.0% ±1.0%
±5.0% ±5.0%±5.0% ±3.0% ±3.0% ±2.0% ±2.0% ±2.0%
500ms, 50ms, 12ms/230VAC 500ms, 50ms, 12ms/115VAC at full load
90 ~ 264VAC
Note.7
47 ~ 63Hz
84% 87%86% 88% 87% 88% 88% 91%
1.5A / 115VAC 0.75A / 230VAC
40A / 115VAC 80A / 230VAC
0.25mA / 240VAC
110 ~ 200% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
110 ~ 140% rated output voltage
Protection type : Clamp by zener diode, output short
-20 ~ +50 (Refer to "Derating Curve")℃
20% ~ 90% RH non-condensing
-20 ~ +85 , 10 ~ 95% RH℃
±℃℃0.03% / (0 ~ 40 )
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
TUV EN60950-1 approved
I/P-O/P:4242VDC
I/P-O/P:100M Ohms / 500VDC / 25 / 70% RH℃
Compliance to EN55022 class B, EN61000-3-2,3
Compliance to EN61000-4,-2,3,4,5,6,8,11,
3 years : 100% load 40 , 12hours / day℃
400Khrs min. MIL-HDBK-217F(25 )℃
93.5*35*51.5mm (L*W*H)
250g ; 60pcs / 17kg / CARTON
See page 3 ; Other type available by customer requested
See page 3 ; Other type available by customer requested
SGA60E09-P1JSGA60E07-P1J
light industry level, criteriaA
SGA60E12-P1J
0 ~ 5A
SGA60E15-P1J
0 ~ 4A 0 ~ 3.33A 0 ~ 2.5A
SGA60E series
SGA60E18-P1J
SGA60E24-P1J
SGA60E48-P1J
0 ~ 1.25A
File Name:SGA60E-SPEC 2015-09-15

60WAC-DC High Reliability Slim Wall-mountedAdaptor
Derating Curve Static Characteristics
100
LOAD (%)
90
80
70
60
50
40
100
70
LOAD (%)
SGA60E series
-20 10 20 30 40
Mechanical Specification
93.5
35
51.5
Ta ( )℃
50
90 115100 130120 160140 200180 240220 264
INPUT VOLTAGE
Unit:mm
UL1571 14AWG 1000 for 5~9V+/-150 0mm
UL1571 16AWG 1000 for 12V+/-150 0mm
UL1185 16AWG 1000 for 15~18V+/-150 0mm
UL1185 18AWG 1500 for 24~48V+/-150 0mm
11 0.5mm±
C"+"
ID 2. 1 x OD 5.5
InsideOutside
Plug Assignment
Standard plug: P1J
P1J
P/N
CENTER
OUTPUT
+
Installation Manual
Please refer to : http://www.meanwell.com/webnet/search/InstallationSearch.html
File Name:SGA60E-SPEC 2015-09-15