1000W Single Out p ut Power Supply
SPECIFICATION
MODE L
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
RATED PO WER
RIPPLE & NOISE (max.)
OUTPUT VOLTAGE ADJ. RANGE
VOLTAGE TOLERANCE
LINE REGUL ATION
LOAD REGULATION
SETUP, RISE TIME
HOLD UP TIME ( Typ.)
VOLTAGE RANGE
FREQUENCY RANGE
POWER FACTOR (Typ.) 0.95/230VAC 0.98/115VAC at full load
EFFICIENCY (Typ.)INPUT
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
LEAK AGE CURRENT
OVERLOAD
PROTECTION
FUNCTION
ENVI RONMENT
SAFETY &
EMC
(Note 4)
NOTE
OVER VOLTAGE
OVER TEMPERATURE
AUXILIARY PO WER(AUX)
REMOTE ON/OFF CONTROL
DC OK SIGNAL
OUTP UT VOLTAGE TRIM
CUR RENT SHARING(CS)
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS UL60950-1, TUV EN60950-1 approved
WITHSTAND VOLTAGE
ISOL ATION RESISTANCE
EMC EMISSION
EMC IMMUNITY
MTBF
DIMENSIONOTHERS
PACKING
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.℃
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”
(as available on http://www.meanwell.com)
5. Derating may be needed under low input voltages. Please check the derating curve for more details.
6. The power supply unit will have no output if the shorting connector is not assembled. It contains two shorting wires: one is from on/off(pin6) to -s(pin2)
and the other is from Vco(pin8) to Vca(pin10). Please refter to function manual for details.
7. In parallel connection, maybe only one unit operate if the total output load is less than 5% of rated load condition.
8. Please consult MEAN WELL for applications of more units connecting in parallel.
RSP - 1 0 00
Features :
■
Universal AC input / Full range
‧
AC input active surge current limiting
‧
Built-in 5V/0.5A auxiliary power
‧
Built-in active PFC function, PF>0.95
‧
Protections: Short circuit / Overload / Over voltage / Over temperature
‧
Output voltage can be trimmed between 40 ~ 110% of the rated output voltage
‧
Forced air cooling by built-in DC fan
‧
High power density 10.7w/inch
‧
1U low profile 41mm
‧
Active current sharing up to 4000W(3+1)
‧
DC OK Signal
‧
Built-in remote ON-OFF control
‧
Built-in remote sense function
‧
5 years warranty
‧
RSP-1000-12 RSP-1000-15 RSP-1000-24 RSP-1000-27 RSP-1000-48
12V
60A
0 ~ 60A
720W
150mVp-p
Note.2
10 ~ 13.5V
Note .3
±1.0% ±1.0% ±1.0% ±1.0% ±1.0%
±0.5% ±0.5% ±0.5% ±0.5% ±0.5%
±0.5% ±0.5% ±0.5% ±0.5% ±0.5%
300ms, 50ms at full load
16ms /230VAC 16ms/115VAC at full load
90 ~ 264VAC 127 ~ 370VDC
Note.5
47 ~ 63H z
83% 85% 88% 88% 90%
12A/ 115VAC 6A/230VAC
25A/115VAC 40A/230VAC
<2.0mA / 240VAC
105 ~ 125% rat ed output power
Protection type : Constant current limiting, recovers automatically after fault condition is removed
13.8 ~ 16.8V 17 ~ 20.5V 27.6 ~ 32.4V 31 ~ 36.5V 56.6 ~ 66.2V
Protection type : Shut down o/p volt age, re-power on to recover
Shut down o/p voltage, recovers automatica lly after temperature goes down
5V @ 0.5A (+5%, - 8%)
Power on : short between on/off(pin6) & -S (pin 2) on C N50 Power off : open between on/off(pin6) & -S(pin2) on CN50
Note. 6
The TTL signal out, PSU turn on = 0 ~ 1V ; PSU turn off = 3.3 ~ 5.6V
Adjustment of output voltage is possi ble between 40 ~ 110% of rated output
Note.6
Please refer to function manual
Note. 7
-20 ~ +60 (Refer to "Derating Curve")℃
20 ~ 90% RH non-condensing
-40 ~ +85 , 10 ~ 95% R H℃
± ℃ ℃0.02%/ (0 ~ 50 )
10 ~ 500Hz, 2G 10min./1cycle , 60m in. each alo ng X, Y, Z axes
I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG , O/P-FG:100M Ohms / 500VDC / 25 / 70% RH℃
Compliance to EN55022 (CI SPR22), EN61000-3-2,-3
Compliance to EN61000-4-2,3,4,5,6,8, 11, EN55024, EN61000- 6-2, EN61204-3, heavy industry level, criteri a A
116.75K hrs mi n. MIL-HDBK-217F (25 )℃
295* 127*41mm (L*W* H)
1.95Kg; 6pcs/12.7Kg/1.15CUFT
15V
50A
0 ~ 50A
750W
150mVp-p
13.5 ~ 16.5V
24V
40A
0 ~ 40A
960W
150mVp-p
20 ~ 26.4V
3
27V
37A
0 ~ 37A
999W
150mVp-p
24 ~ 30V
(Note.8)
Fil e Name: RSP-1 000-SP EC 2013 -11-01
s eri e s
48V
21A
0 ~ 21A
1008W
150mVp-p
43 ~ 55V

1000W Single Out p ut Power Supply
RSP - 1 0 00
s eri e s
Mechanical Specification
277.7
295
277.7
Pin No.Pin No.Pin No.
Assig nmentAssig nmentAssi gnment
951
ON/OFF
8
CS
Vco
106
11,127
VciDC- OK+S
Vca
GND
AC Inp ut Ter mi na l
Pin No. Ass ig nment
Pin No.
Assig nment
1
AC/N
2
AC/L
3
FG
6
3-M4 L=6
41
21 34.5
+V
-V
SVR 51
CN50
TB1
6
1
2
11
12
3
2
1
3-M4 L=4
3-M4 L=6
Control Pin No . Assig nment (CN 50) : HR S DF11- 12DP-2DS or e quiv al en t
2
3
4
-S
G- AUX
5V-AUX
Block Diagram
I/P
EMI
FILTER
ACT IVE
INR USH
CU RRENT
LIM ITING
RECTIFIERS
&
PFC
POWER
SWIT CHING
O.L.P.
PFC
CONTROL
PWM
CONTROL
AUX
POWER
FAN
RECT IFIERS
&
FILTER
CURREN T
SHARE
DETEC TI ON
CIRCUIT
O.V.P.
RECTIFIERS
CONTROL
ON/OFF
RECT IFIERS
&
FILTER
Derating Curve Static Characteristics
Matin g Housing
HRS DF 11-12DS
or equi valent
Case No. 952 B Un it:mm
Air f low
dir ection
Term inal
HRS DF 11-**SC
or equi valent
PFC fo sc : 110K Hz
+S
+V
-V
-S
CURRENT
SHARE
DC OK
V_TRI M
PWM fosc : 9 0K Hz
ON/OFF
AUX POWER(5V/ 0. 5A)
AUX GND
100
80
60
40
20
-20 0 10 20 30 4 0 50 60 70
AMBIENT TEMPERATURE ( )℃
(HO RIZON TAL )
100
90
80
70
60
50
40
90 95 100 115 264
INPUT VOLTAGE (VAC) 60H z
Fil e Name: RSP-1 000-SP EC 2013 -11-01

1000W Single Out p ut Power Supply
Function Description of CN50
RSP - 1 0 00
s eri e s
Pin No. Function
1
2
3
4
5
6
7
8
9
10
11,12
Description
Positive sensing. The +S signal should be connected to the positive terminal of the load. The +S and -S leads should be twisted in pair to
+S
minimize noise pick-up effect. Th e maximum line drop compensation is 0.5V.
Negative s ensi ng. The -S signal should b e connected to the negative terminal of the load. The -S and +S leads should be twisted in pair to
-S
minimize noise pick-up effect. Th e maximum line drop compensation is 0.5V.
G-AUX
Auxiliary voltage output ground. The signal return is isolated from the output terminals (+V & -V).
Auxiliary voltage output, 4.6~ 5.25V, referenced to pin 3(G-AUX). The maximum load c urrent is 0.5A. This output has the built-in oring
5V-AUX
diodes and i s not controlled by the "remote ON/OFF control".
Open collector signal, referenced to pin11,12(GND). Low when PSU turns on. The maxim um sin k cur rent is 10mA and the maximum
DC_OK
external voltage is 5.6V.
ON/OFF
Turns the output on and off by electric al or dry contact between pin 6 ( ON/OFF) and pin 2 (-S). Short: Power ON, Open: Power OFF.
Current sharing signal. When units are connected in par allel, the CS pins of the units should be connected to allow current balance
CS
between units.
Vco
Short connectin g between Vco (pin8) and Vca (pin10) if output voltage tr im functio n is not used.
Connect to exter nal DC voltage source for output voltage triming, referenced to pin 2 (-S). Output voltage can be trimmed between
Vci
40 ~ 110% of the rated output v oltage.
Connect to exter nal resistor (1/8W) for output voltage trim ing. Output voltage c an be trimmed between 40 ~ 110% of the rated output
Vca
voltage. Pleas e refer to function manual for details.
GND
These pins connect to the negativ e terminal (-V). Return for DC_OK S ignal output.
Function Manual
1."Remote ON/O FF" an d "Out pu t voltage trim" functi ons are n ot u se d.
The power su pp ly uni t wi ll have no ou tp ut i f th e shorting conn ec to r (a ccessory come s alon g with the PSU) is no t as se mble d. It conta ins
two sh orting w ir es : one is f ro m ON /O FF (pin6) to -S (pi n2) and the oth er is from V co (pin8) to Vc a (p in10 ).
LO AD
+
SV R51 CN 50
-V+V
-
1 11
2 12
Fig 1. 1
TB1
1
+S
AUX G
-S
AUX
2
(Short ing co nne ctor)
CN5 0
DC_OK
ON/OFF
CS
Vco
11
Vci
GND
Vca
GND
12
Fil e Name: RSP-1 000-SP EC 2013 -11-01

1000W Single Out p ut Power Supply
2.Remote O N/OF F
The PSU can be t urned ON/ OF F by using t he "Remote
ON/OFF " fu nction
Bet ween O N/OFF(p in6 ) an d -S(pin 2)
SW ON (Short )
SW OFF (Open)
Out pu t Statu s
ON
OFF
SV R51 CN 50
-V+V
1 11
2 1 2
RSP - 1 0 00
TB1
s eri e s
3.DC_OK si gnal
"DC_ OK " is an open collector si gn al.
It ind icat es t he output status of the P SU . It can operate
in t wo w ays : One is sinkin g curren t from exte rnal TTL
signal ; t he other is sending o ut a TTL volta ge sig na l.
3-1 Si nk curre nt :
The ma xi mu m si nk current is 10mA and the maximum
ex tern al v ol tage i s 5. 6V.
3-2 TT L vo ltage sign al :
Bet ween DC- OK(pi n5) and GND (pin 11&1 2)
0 ~ 1V
3.3 ~ 5.6V
Out pu t Statu s
ON
OFF
LO AD
+
-
-V+V TB1SV R51
Fig 2. 1
1 11
2 1 2
CN 50
Fig 3. 1
AUX G
AUX
SW
AUX G
AUX
CN5 0
DC_OK
ON/OFF
CN5 0
DC_OK
ON/OFF
CS
Vco
CS
Vco
Vci
Vca
Vci
Vca
11
GND
GND
12
11
GND
GND
12
1
+S
-S
2
1
+S
-S
2
4.Remote S en se
The remote s en sing c ompensates volt age drop o n the
load w iring up t o 0.5V.
+S
(pin 1)
+
LOAD
-V+V TB1CN 50SV R51
-S
(pin 2)
-
1 11
2 12
Sense lin es shou ld
be twi sted in pairs
Fig 4. 1
1
+S
-S
2
CN5 0
AUX G
DC_OK
CS
Vci
AUX
ON/OFF
Vco
Vca
Fil e Name: RSP-1 000-SP EC 2013 -11-01
11
GND
GND
12

1000W Single Out p ut Power Supply
5.Output Vo ltage TR IM
Ou tput vol ta ge of RS P-1000 can be t ri mm ed bet we en
40% ~ 110% of its rat ed value by the f ol lowing metho ds
and +S & + V, -S & -V also need to be c onne ct ed on CN50:
(1)Using ext er nal vo ltag e sour ce be tween
"Vci"(pin9 ) an d "-S" (p in 2) that is show n in Fig5.1
Vout
120
100
80
60
40
20
1
Non-L inear
3
EXTERNAL VOLTAGE (VDC)
OVP 120%(Typ.)
5
Vci(Re ferenced to -S)
RSP - 1 0 00
1 11
-V+V
1
+S
AUX G
-S
AUX
2
+V
-V
LOA D
2 1 2
CN 50
CN5 0
DC_OK
ON/OFF
Exte rnal Volt age
Fig 5. 1
CS
Vco
Vci
Vca
TB1SV R51
11
GND
GND
12
s eri e s
(2)Connectin g a re sistor externally t hat in s hown in Fig 5.2 & F ig 5 .3
(A) O/P voltage go es dow n
Vout
100
90
80
Non -Linear
70
60
50
40
3902560
82041K2
2K264K7
open
R1, 1/8W(Typ.)
EXTERNAL RESI STOR ( ) Ω
(B)O/P voltage g oes up
Vout
110
Non -Linear
105
100
OVP 120%(Typ.)
AUX G
AUX
AUX G
AUX
CN5 0
DC_OK
ON/OFF
R1
Fig 5. 2
CN5 0
DC_OK
ON/OFF
CS
Vco
CS
Vco
1
+S
-S
2
+V
-V
LOA D
1
+S
-S
2
Vci
Vca
Vci
Vca
11
GND
GND
12
11
GND
GND
12
R2
open
18K
7K5
EXTERNAL RESI STOR ( ) Ω
R2, 1/8W(Typ.)
+V
-V
LOA D
Fig 5. 3
Fil e Name: RSP-1 000-SP EC 2013 -11-01

1000W Single Out p ut Power Supply
RSP - 1 0 00
6.Curr en t Shar ing with Remo te S en si ng
RSP-1000 h as t he built -in active curren t sh ar ing fu nction and can be c onnected in p aralle l to provi de higher outpu t power :
(1)Parallel op erat ion is availab le by conne ct ing th e un its shown a s belo w.
(+S,-S and C S ar e connected mut uall y in parallel) .
(2)Diff erence of ou tput v oltages am on g pa rallel units shou ld b e le ss tha n 0.2 V.
(3)The tot al o ut pu t cu rren t must not ex ce ed the v alue de termin ed by the fo llowing equ atio n.
(output cu rrent at paral le l operation)=(R ated c urre nt per u nit) (Numbe r of u nit) 0.9× ×
(4)In para llel o pera tion 4 units is the m ax im um, please co ns ult th e ma nu fa ct urer f or applications o f more connecting i n pa rall el .
(5)The power s uppl ie s should be par al lele d us ing short and l arge dia meter wi ring and th en c on nected to the loa d.
PSU PSU PSU PSU
s eri e s
1 1 1
2 1 2
SVR51 SVR51 SVR51 SVR51
+V +V +V +V-V -V -V - V
CN50 CN50 CN50 CN50
TB1 TB1 TB1 TB1
1 11
2 12
1 1 1
2 1 2
-V
+V
LOA D
Fig 6. 1
Se nse lin es shou ld
be twis ted in pai rs
1111 11111111
+S+S+S+S
-S-S-S-S
2222 121 21 21 2
Note : In para ll el con nectio n, maybe on ly o ne unit (master) op erat e if the total output loa d is les s th an 5% of ra ted load c ondition.
The othe r PSUs (slaves) may g o in to s tandby mode a nd t heir o utpu t LE Ds will not turn on .
CS (pin7 )
AUX GAUX GAUX GAUX G
AUXAUXAUXAUX
1 1 1
2 1 2
+S( pin1 )
-S(pi n2)
DC_OKDC_OKDC_OKDC_OK
ON/OFFON/OFFON/OFFON/OFF
CN5 0CN5 0CN 50CN 50
CSCSCSCS
VciVciVciVci
GNDGNDGNDGND
VcoVcoVc oV co
VcaVcaVcaVca
GNDGNDGNDGND
Fil e Name: RSP-1 000-SP EC 2013 -11-01