SPECIFICATION
MODE L PLP-60-12 PLP-60-24 PLP-60-48
OUTPUT
INPUT
PROTECTION
ENVI RONMENT
SAFETY &
EMC
NOTE
DC VOLTAGE
CONSTANT CU RRENT REGION
RATED CURRENT
CURRENT RANGE
RATED PO WER
RIPPLE & NOISE (max.)
CURRENT ADJ. RANGE
VOLTAGE TOLERANCE
LINE REGUL ATION
LOAD REGULATION
SETUP TIME
VOLTAGE RANGE
FREQUENCY RANGE
POWER FACTOR (Typ.)
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
INRUSH CURRENT (max.)
LEAK AGE CURRENT
OVER CURRENT
SHORT CIRCUIT
OVER VOLTAGE
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
WITHSTAND VOLTAGE
ISOL ATION RESISTANCE
EMC EMISSION
EMC IMMUNITY
MTBF
DIMENSIONOTHERS
PACKING
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.℃
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Derating may be needed under low input voltage. Please check the static characteristics for more details.
5. lease refer to "DRIVING METHODS OF LED MODULE".P
6. Heat sink HS1,HS2 can not be shorted.
7. Heat sink HS1 must have safety isolation distance with system case.
8. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the
complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
9. Direct connecting to LEDs is suggested, but is not suitable for using additional drivers.
10. To fulfill requirements of the latest ErP regulation for lighting fixtures, this LED power supply can only be used behind a switch without permanently
connected to the mains.
12V 24V 48V
9 ~ 12V
Note. 5
5A
0 ~ 5A
60W 60W 62.4W
4.5V p-p 4.5V p-p
Note.2
3.75 ~ 5A
Note .3
±10%
±3.0%
±5.0%
500ms / 230VAC 1200ms / 115VAC at full load
Note.4
90 ~ 264VAC
47 ~ 63H z
PF 0.9 at 75 ~ 100% l oad, 115VAC / 230VAC≧
84% 88% 89%
0.8A /115VAC 0.4A/230VAC
COLD START 35A(t =55 s measured at 50% I ) at 230VAC
<0.75mA / 240VAC
100 ~ 110%
Note.5
Protection type : Constant current lim iting, recovers automati cally after fault condition is removed
Hiccup mode, rec over s automaticall y after fault conditi on is removed
15 ~ 18V 28 ~ 35V 57 ~ 63V
Protection type : Shut down o/p volt age, re-power on to recover
-30 ~ +70 (Refer to "Derating Curve")℃
20 ~ 95% RH non-condensing
-40 ~ +80 , 10 ~ 95% R H℃
± ℃ ℃0.03%/ (0 ~ 50 )
10 ~ 500Hz, 2G 12mi n./1cycle , per iod for 72min. each along X, Y, Z axes
UL8750, T UV E N61347-1, EN6 1347 -2-13, CSA C2 2.2 No. 25 0.0-0 8(ex ce pt for 48V) approved ; design ref er t o UL 6095 0-1
I/P-O/P :3.75K VAC I/P -F G:2 KVAC O/ P-FG :0.5KVAC
I/P-O/P, I/P-FG , O/P-FG:100M Ohms / 500VDC / 25 / 70% RH℃
Compliance to EN55015, EN61000-3-2 Clas s C( 75% lo ad); E N61000-3-3≧
Compliance to EN61000-4-2,3,4,5,6,8, 11, EN55024,EN61547, light industry level, criteria A
583.3K hrs min. MI L-H DBK- 217F (25 )℃
101.6*50.8*29.6m m (L*W*H)
0.16Kg; 96pcs/16.4Kg/0.89CUFT
width peak
μ
18 ~ 24V 36 ~ 48V
2.5A
0 ~ 2.5A
1.875 ~ 2.5A
( for 48V only ) ( except for 4 8V )
1.3A
0 ~ 1.3A
4.8V p-p
0.975 ~ 1.3A
Fi le Name :PL P-6 0-SP EC 201 4-03- 13

60W Single Outp u t L ED Power Supply
PLP -60
s e r i es
Mechanical Specification
AC Inp ut C onne ctor (CN 1) : JST B 3P -VH or equivalent
Pin No.
Assig nment
2
No Pin
3 2
AC/N -V
Block Diagram
3.1 75
FS1
1
2
3
CN1
Matin g Housing
JST VHR
or equi valent
Term inal
JST S VH-21 T-P1. 1
or equi valent
101. 6
95. 25
Unit :mm
HS2HS1
SVR1
CN2
1
2
1.HS1,HS2 can not be shorted.
2.HS1 must have safety isolation distance
with system case.
DC Outpu t Co nnecto r (C N2) : JST B2 P- VH or equivalent
Pin No.1
Assig nmentAC/L
1
: Groun di ng r equired
+V
Matin g Housing
JST VHR
or equi valent
Term inal
JST S VH-21 T-P1. 1
or equi valent
fos c : 90 KHz(115 VAC)
120K Hz(2 30 VAC)
RECTI FIERS
&
FILTER
FG
I/P
EMI FILT ER
&
RECTI FIERS
O.L.P.
POW ER
SWI TCHING
PWM & PFC
CONTR OL
Derating Curve Static Characteristics
100
80
60
50
40
20
-30 -25 -5 0 20 40 50 55 60 7 0
12V
AMBIENT TEMPERATURE ( )℃
Othe rs
(HORI ZONTAL)
100
90
80
70
60
50
40
90 1 00 125 135 145 155 165 175 1 80 200 230 264
INPUT VOLTAGE (V) 60Hz
+V
-V
DETEC TION
CIRCU IT
O.C.P.
O.V.P.
Fi le Name :PL P-6 0-SP EC 201 4-03- 13

60W Single Outp u t L ED Power Supply
Power Factor Characteristic
Constant Current Mod e
1 . 0 0
0 . 9 8
0 . 9 6
0 . 9 4
0 . 9 2
0 . 9 0
0 . 8 8
0 . 8 6
0 . 8 4
0 . 8 2
0 . 8 0
0 . 7 8
5 0 % 6 0 % 7 0 % 8 0 % 9 0 % 1 0 0 %
(60W)
LOAD
EFFICIENCY vs LOAD (48V Model)
PL P- 60 ser ies pos se ss sup eri o r wor king effici en cy t hat up to 89% can be rea ched in f iel d ap plica tion s.
94
92
90
88
86
84
82
80
78
76
74
72
70
68
66
64
62
60
10% 20% 30% 40% 50% 60% 70% 80% 90% 100%
2 3 0 V
1 1 5 V
230V
115V
PLP -60
s e r i es
LOAD
DRIVING METHODS OF LED MODULE
Th is LED power sup ply is sugges ted to work in constant current m ode area (C C) to driv e the LE Ds.
100
75
(min.)
Current area
Hiccup
Protection
50 100
Typic al LED power sup ply I -V curve
Constant
Io (%)
In th e con stan t curre nt r egio n, the hi ghest vol tage at th e output of the dr iver
dep ends on th e conf igur atio n of the end s ys te ms.
Sh ou ld the re be a ny co mpati bil it y iss ue s, p lease con tact M EAN WE LL .
Fi le Name :PL P-6 0-SP EC 201 4-03- 13