MEANWELL MW PLM-12E-700 Datasheet

Page 1
12W Single Output LED Power Supply
110
MM
F
SELV
IP30
PLM-12 series
(for Blank type only)
Features Applications230VAC only or Full range (up to 295VAC)
models available
Built-in active PFC functionConstant current design
Indoor LED lightingLED office lightingLED commercial lighting
LED decorative lightingProtections:Short circuitCooling by free air convectionFully isolated plastic caseClass power unit, no FGClass 2 power unit (Blank type only)No load power consumption <0.5WHigh reliability,low cost2 years warranty
18
Description
PLM-12 is a 12W economical AC/DC LED power supply series. Incorporating a built-in active PFC design, PLM-12 provides a high Power Factor value greater than 0.9. In addition, with the low no load power consumption below 0.5W, and the setup time less than 500ms, PLM-12 is complied with the ErP regulation required by European Union for lighting fixtures.
PLM-12 is a class (without FG pin) power unit housed with the UL 94V-0 rated flame retardant plastic case. The /O terminals are designed with screw-less clamp style terminal block that greatlyI simplifies the wiring installation. Two types of models with different input voltage range are offered: PLM-12 series, which operates from 110~295VAC, and PLM-12E series, which operates from 180~295VAC.These two series are both constant current output design, supplying models with the
current of 350mA, 500mA, 700mA and 1050mA, respectively.
Model Encoding
- 350PLM - 12
E
Output current
Blank: AC input range 110~295VAC
{
E:AC input range 180~295VAC
Output wattage
Series name
File Name:PLM-12-SPEC 2015-06-03
Page 2
SPECIFICATION
MODEL
CONSTANT CURRENT REGION
RATED CURRENT
NO LOAD OUTPUT VOLTAGE
OUTPUT
INPUT
RATED POWER
RIPPLE & NOISE
(max.)
CURRENT ACCURACY
SETUP TIME
VO LTAGE RA NG E
FREQUENCY RANGE
POWER FACTOR
TOTALHARMONIC DISTORTION
EFFICIENCY (Typ.)
AC CURRENT
INRUSH CURRENT(Typ.)
MAX. No. of PSUs on 16A CIRCUIT BREAKER
12W Single Output LED Power Supply
PLM-12 -500
15 ~ 24V
0.5A
30V
12W
2.4Vp-p
3.6Vp-p
84%
83%
Note.2
Note.5
(max.)
Blank type
E type
Note.3
Note.4
Blank type
E type
Blank type
E type
Blank type
E type
PLM-12 -350
22 ~ 36V
0.35A
42V
12.6W
3.6Vp-p
5.5Vp-p
±5.0%
Blank type: 500ms / 115VAC, 230VAC at full load; E type: 500ms / 230VAC at full load
Blank type: 110 ~ 295VAC 156 ~ 417VDC; E type: 180 ~ 295VAC 254~ 417VDC
47 ~ 63Hz
PF 0.97/115VAC,PF 0.95/230VAC,PF>0.9/277VAC(at full load)(Please refer to "Power Factor Characteristic" curve)≥≥
PF 0.95/230VAC,PF 0.9/277VAC (at full load)(Please refer to "Power Factor Characteristic" curve)≥≥
THD< 20% when output loading 60% at 115VAC/230VAC input and output loading 75% at 277VAC input≧≧
THD< 20% when output loading 60% at 230VAC input and output loading 75% at 277VAC input≧≧
85%
84%
Blank type: 0.15A/115VAC 0.08A/230VAC 0.07A/277VAC; E type: 0.08A/230VAC 0.07A/277VAC
COLD START 15A(twidth=50 s measured at 50% Ipeak) at 230VACμ
160 units (circuit breaker of type B) / 160 units (circuit breaker of type C) at 230VAC
PLM-12 -700
11 ~ 18V
0.7A
22V
12.6W
2.4Vp-p
3.6Vp-p
83%
82%
PLM-12 series
PLM-12 -1050
7 ~ 12V
1.05A
16V
12.6W
1.8Vp-p
2.7Vp-p
81%
78%
LEAKAGE CURRENT
PROTECTION
SHORT CIRCUIT
WORKING TEMP.
WORKING HUMIDITY
ENVIRONMENT
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
SAFETY & EMC
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
EMC EMISSION
EMC IMMUNITY
MTBF
OTHERS
DIMENSION
PACKING
NOTE
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Please see AC input voltage drop vs. output current characteristics table.""
4. Derating may be needed under low input voltage, please check the static characteristic for more details.
5. Constant current operation region is within 60% ~100% rated output voltage. This is the suitable operation region for LED related applications, but please
6. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the
7. Direct connecting to LEDs is suggested, but is not suitable for using additional drivers.
0.25mA / 240VAC
Hiccup mode, recovers automatically after fault condition is removed.
-30 ~ +50
20 ~ 90% RH non-condensing
-40 ~ +80 , 10 ~ 95% RH
±℃ ℃0.06%/ (0 ~ 50 )
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
UL8750, CSA C22.2 No. 250.13-12(for Blank type only); ENEC EN61347-1, EN61347-2-13, EN62384, IP30 approved
I/P-O/P:3.75KVAC
I/P-O/P:100M Ohms/500VDC / 25 / 70%RH
Compliance to EN55015,EN61000-3-2 Class C( 60% load);EN61000-3-3
Compliance to EN61000-4-2,3,4,5,6,8,11;EN61547, light industry level, criteria B(surge 2KV)
808.162Khrs min. MIL-HDBK-217F (25 )
145*38*22mm (L*W*H)
0.126Kg;60pcs/8.6 Kg/0.48CUFT
reconfirm special electrical requirements for some specific system design.
complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
File Name:PLM-12-SPEC 2015-06-03
Page 3
12W Single Output LED Power Supply
PLM-12 series
Mechanical Specification
1
2
4.5
TB1
Case No.PLM-25 Unit:mm
145
4.5
3.5
ψ
4.5
Tcase
4.5
3.5
Tcase: Max. Case Temperature.
65
12
38
22
NOTE: The input and output line for using UL1015 18AWG*2C is suggested
Terminal Pin No. Assignment (TB1) : SWITCHLAB MWX201-75002EB(GRAY)
Pin No. Pin No.
Assignment Assignment
AC/L +V
11
AC/N -V
22
Terminal Pin No. Assignment (TB2) : SWITCHLAB MWX201-75002B(BLUE)
2
1
TB2
Block Diagram
I/P
EMI FILTER
Derating CurveDerating Curve
100
100
80
80
60
60
40
40
LOAD (%)LOAD (%)
LOAD (%)
20
20
RECTIFIERS
POWER
SWITCH-
ING
PWM /PFC CONTROL
RECTIFIERS
&
FILTER
Static Characteristics
100
90
80
70
60
50
LOAD (%)
40
+V
-V
-25 -5 0 15 30
-25 -5 0 15 30 40 50
-30 60
AMBIENT TEMPERATURE ( )
(HORIZONTAL)
110 120 125 135 145 155 165 175 180 200 230 295
180 185 190 195 200 205 210 220 230 240 295215
INPUT VOLTAGE (V)
File Name:PLM-12-SPEC 2015-06-03
(Blank type) (E type)
Page 4
0.8
0.82
0.84
0.86
0.88
0.9
0.92
0.94
0.96
0.98
1
1.02
60% 70% 80% 90% 100%
110V
230V
277V
12W Single Output LED Power Supply
0.82
0.84
0.86
0.88
0.9
0.92
0.94
0.96
0.98
60% 70% 80% 90% 100%
230V
277V
79
80
81
82
83
84
85
86
60% 70% 80% 90% 100%
230V
277V
79
80
81
82
83
84
85
86
60% 70% 80% 90% 100%
110V
230V
277V
Power Factor Characteristic
PLM-12 series
Constant Current Mode
PF
LOAD
Blank type
EFFICIENCY vs LOAD (500mA Model)
(12W)
PF
Constant Current Mode
LOAD
E type
(12W)
EFFICIENCY (%)
LOAD
Blank type
AC input voltage drop vs. output current characteristics
AC input drop
Io drop
NOTE: Output current will return to the rated value within 50ms
10%
<15%
8%
<11%
5%
<7%
EFFICIENCY (%)
LOAD
E type
3%
<6%
File Name:PLM-12-SPEC 2015-06-03
Loading...