mJ!~
240W
Single
Output
lndustrial
DIN
RAIL
&
c&?)c@us
ND
6
R33100
RoHS
R-240 series
(A[
■
Features
• Universal AC input / Full range
• Built-in active PFC function
• Protections: Short circuit / Overload / Over voltage
/ Over temperature
• Cooling by free air convection
• Can be installed
• UL 508 (industrial control equipment) approved
• EN61000-6-2(EN50082-2) industrial immunity level
• 100% full load burn-in test
• 3 years warranty
■
Description
NDR-240 is one
or TS-35/15 mounting rails. The body is designed 63mm
cabinets.
EN61000-3-2, the norm the European Union regulates for harmonic current.
NDR-240 is designed with metal housing that enhances the unit's power dissipation. With working efficiency
up to 90%, the
convection. lt is equipped with constant
or capacitive applications. The complete protection functions and relevant certificates for industrial control
apparatus (UL508, TUV EN60950-1, and etc.) make NDR-240 a very competitive power supply solution
for industrial applications.
The
on
entire
entire
DIN
rail TS-35/7.5 or 15
economical
series
series
slim 240W Din rail
adopts
can
the
operate
full
range
at the
current
power
ambient
supply
in
AC
input
temperature
mode for over-load protection, fitting
■ Applications
• lndustrial control system
• Semi-conductor fabrication equipment
• Factory automation
• Electro-mechanical
series, adapt
width, which allows space saving inside the
from
90VAC
tobe
to
264VAC
between
installed on
and
-20°C
and
various
TS-35/7.5
conforms
70°C
under
inductive
to
air
■
Model Encoding
NDR-240-~
1 Output voltage
~------
Output wattage
Series name
File
Name:NDR-240-SPEC
2018-11-05

SPECIFICATION
MODEL
DCVOLTAGE
RATED
CURRENT
CURRENT
RATEDPOWER
RIPPLE & NOISE
OUTPUT
INPUT
PROTECTION
ENVIRONMENT
SAFETY&
EMC
(Note4)
OTHERS
NOTE
VOLTAGEADJ.
VOLTAGE
UNE
REGULATION
LOAD
REGULATION
SETUP,
RISE
HOLD
UP
VOLTAGE
FREQUENCY
POWER
EFFICIENCY
AC
CURRENT
IN
RUSH
LEAKAGE
OVERLOAD
OVER
VOLTAGE
OVER
TEMPERATURE
WORKING
WORKING
STORAGE
TEMP.
COEFFICIENT
VIBRATION
SAFETY
WITHSTAND
ISOLATION
EMC
EMISSION
EMC
IMMUNITY
MTBF
DIMENSION
PACKING
1.
All
parameters
2.
Ripple & noise
3.
Tolerance : includes
4.
Derating
5.
Installation
In
case
6.
The
power
EMC
7.
The
2000m(6500ft).
(as
available
240W
Single
RANGE
(max.)
RANGE
TOLERANCE
TIME
TIME
(Typ.)
RANGE
RANGE
FACTOR
(Typ.)
(Typ.)
(Typ.)
CURRENT
STANDARDS
directives.
ambient temperature derating of 3.5°C/1000m
(Typ.)
CURRENT
TEMP.
HUMIDITY
TEMP.,
HUMIDITY
VOLTAGE
RESISTANCE
NOT
are
may
be
needed
clearances : 40mm
the
adjacent
supply
For
on
httpJ/www.meanwell.com)
Output
NDR-240-24
24V
10A
O~
240W
Note.2
150mVp-p
24-28V
±1.0% ±1.0%
Note.3
±0.5% ±0.5%
±1.0% ±1.0%
1500ms,
28ms/230VAC
Note.4
90 -264VAC
47 -63Hz
PF>0.98/115VAC,
88.5%
2.5A/115VAC
20A/115VAC
<1mA/240VAC
105 -130%
Protection
29Protection
Shut
-20
20 -95%
-40±0.03%/°C
Component:10-
UL508,
I/P-O/P:3KVAC
I/P-O/P,
Compliance
Compliance
EAC
230.2K
63*125.2'113.5mm
1Kg;
specially
measured
sei
up
tolerance,
under
device
is a heat
is
considered a component
guidance
lndustrial
10A
100ms/230VAC
127 -370VDC
PF>0.95/230VAC
35A/230VAC
rated
output
type : Constant
33V
type : Shut
down
o/p
voltage,
- +
70°C
(Refer
RH
non-condensing
+85°C,
10-95%
(0 -50°C)
500Hz,
TUV
EN60950-1,
I/P-FG:2KVAC
I/P-FG,
O/P-FG:>100M
to
EN55032
to
EN61000-4-2,3,4,5,6,8,
TP
TC
020
hrs
min.
12pcs/13Kg/1.1CUFT
mentioned
at
on
20MHz
low
on
top,
how
line
input
20mm
source,
to
are
measured
of
bandwidth
regulation
voltage.
on
15mm
which
perform
22ms/115VAC
1.3A/230VAC
down
recovers
to
"Derating
RH
MIL-HDBK-217F
(W'H'D)
Please
the
these
DIN
RAIL
3000ms,
at
power
current
limiting,
o/p
voltage,
automatically
Curve")
2G
10min./1cycle,
EAC
TP
TC
Ohms/
(CISPR32),
at
230VAC
by
using a 12"
and
load
regulation.
check
bottom,
5mm
clearance
will
be
installed
EMC
tests,
with
fanless models
100ms/115VAC
full
load
at
full
load
recovers
automatically
re-power
on
alter
temperature
60min.
each
004, BSMI
O/P-FG:0.5KVAC
EN61204-3
(25°C)
the
is
CNS14336-1
500VDC / 25°C/
Class
11,
EN55024,
input,
rated
twisted
pair-wire
derating
curve
on
the
left
into a final
please
refer
and
and
recommended.
at
full
load
to
recover
along
X,
approved
70%
RH
B,
EN61000-3-2,-3,
EN61000-6-2
load
and
25°C
terminated
for
more
right
side
equipment.
to
"EMI
testing
of 5°C/1000m
NDR-240-48
48V
5A
0 -
5A
240W
150mVp-p
48-
55V
90%
alter
fault
56-
65V
goes
down
Y, Z axes;
;(meet
(EN50082-2),
of
ambient
with a 0.1
details.
are
recommended
The
final
of
component
with
NDR-240 series
condition
is
removed
Mounting:
EAC
equipment
EN60204-1)
TP
EN61204-3,
temperature.
uf & 47uf
power
fan
models
Compliance
TC
020,
when
must
to
CNS13438
heavy
parallel
capacitor.
loaded
permanently
be
re-confirmed
supplies."
for
operating altitude higher
IEC60068-2-6
industry
level,
with
that
it
criteria
full
still
power.
meets
than
A,
File
Name:NDR-240-SPEC
2018-11-05

mJ!~
■
Block
Diagram
240W
Single
Output
lndustrial
DIN
RAIL
ND
R-240 series
fosc:
70KHz
1/P
FG
c 4
■
Derating
100
80
60
50
~
40
C
<C
0
...1
20
Curve
-20
EMI
FILTER
&
RECTIFIERS
10
t
100
90
80
70
60
50
40
90
RECTIFIERS
FILTER
~---~
derating
100
PFC
CIRCUIT
20
30
40
50
60 70
POWER
SWITCHING
(VERTICAL)
■
Output
~
C
<C
0
...1
r--
VS
-------
r--
---~---+-
input
O.C.P.
DETECTION
CIRCUIT
O.V.P.
voltage
&
125 135 145 155 165 175 180
-.-----.--
--{J
-+--------{
200 230 264
+V
J
-V
AMBIENT
TEMPERATURE
(°C)
INPUT
VOLTAGE
(V)
60Hz
File
Name:NDR-240-SPEC
2018-11-05

mJ!~
■
Mechanical
240W
Single
Specification
113
Output
5
lndustrial
DIN
RAIL
©
11°1°1°1°11
0
TopView
°
00
ND
0
0
R-240 series
Gase
No.979C
Unit:mm
■
Installation
©
©
SideView
lnstruction
©
p
TB2
+VADJ.
"(Y
+
DCOKO
N
.,;
N
TB1
1 2 3
©
FrontView
BottomView
©
q
~-------
Terminal
Pin
No.
1
2
3 AC/LorDC+
Terminal
Pin
No.
1,2
3,4
SideView
Pin
No.
Assignment
Assignment
FG@
AC/N
orDC-
Pin
No.
Assignment
Assignment
DCOUTPUT-V
DCOUTPUT+V
-
(TB1)
(TB2)
■
Installation
Please
BackView
Manual
refer
to:
http://www.meanwell.com/manual.html
ADMISSIBLE
(For
reference
DIN-RAIL:TS35/7.5
only.
Not
included
with
OR
unit.)
TS35/15
This
series
For
installation
fits
DIN
rail
details,
TS35/7.5
please
refer
or
TS35/15.
to
File
the
lnstruction
Name:NDR-240-SPEC
manual.
2018-11-05