90WAC-DC High Reliability IndustrialAdaptor
THOMAS SAMUELTHOMAS SAMUEL
THOMAS SAMUELTHOMAS SAMUEL
IS13252 K60950-1 TPTC004 UL62368-1 EN62368-1 J60950-1 AS/NZS60950-1
R33100
RoHS
GST90A series
GB4943.1 IEC62368-1MS IEC60950-1
■ Features
Universal AC input / Full range
3 pole AC inlet IEC320-C14,Class power unitⅠ
Built-in active PFC function
(optional)
Global certificates
■ Applications
Consumer electronic devices
Telecommunication devices
Office facilities
Industrial equipments
No load power consumption< 0.15W
Energy efficiency Level VI
Comply with EISA 2007/DoE,NRCan,Korea K-MEPS,
AU/NZ MEPS,EU ErP and CoC Version 5
Protections: Short circuit / Overload / Over voltage
/ Over temperature
Fully enclosed plastic case
-30~+70 wide range working temperature℃
LED indicator for power on
3 years warranty
■ Description
GST90A is a highly reliable, 90W desktop style single-output green adaptor series. This product is a classⅠ
power unit (with FG), equipped with a standard IEC320-C14 AC inlet and adopting the input range from
90VAC to 264VAC. The entire series supplies different models with output voltages ranging between 12VDC
and 48VDC that can satisfy the demands for various types of consumer electronic devices.
With the efficiency up to 91% and the extremely low no-load power consumption below 0.15W,GST90A is
compliant with USA EISA 2007/DoE, Canada NRCan, Australia and New Zealand MEPS, EU ErP and
Code of Conduct (CoC) Version 5. The supreme feature allows the adaptor to save the energy when it is either under
the operating mode or the standby mode. The entire series utilizes the 94V-0 flame retardant plastic case.
GST90A is certified for the international safety regulations.
Korea K-MEPS,
■ Model Encoding
-A12GST P1M90
DC plug type
Output voltage
IEC320-C14 AC inlet
Rated wattage
Series name
P1M: Standard model,2.5 x5.5 x11mm,C+,tuning fork typeψψ
{
Other options available by customer requested (see Page 4~5)
File Name:GST90A-SPEC 2019-11-08

SPECIFICATION
ORDER NO.
SAFETY MODEL NO.
DC VO LTAGE
RATED CURRENT
CURRENT RANGE
RATED POWER (max.)
OUTPUT
INPUT
PROTECTION
ENVIRONMENT
SAFETY &
EMC
(Note. 9)
OTHERS
CONNECTOR
NOTE
RIPPLE & NOISE (max.)
VOLTAGE TOLERANCE
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
HOLD UP TIME (Typ.)
VOLTAGE RANGE
FREQUENCY RANGE
POWER FACTOR (Typ.)
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
INRUSH CURRENT (max.)
LEAKAGE CURRENT(max.)
OVERLOAD
OVER VOLTAGE
OVER TEMPERATURE
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS Note. 8
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
EMC EMISSION
EMC IMMUNITY
MTBF
DIMENSION
PACKING
PLUG
CABLE
1. All parameters are specified at 230VAC input, rated load, 25 70% RH ambient. ℃
2. DC voltage: The output voltage set at point measure by plug terminal & 50% load.
3. Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1 f & 47 f capacitor.
4. Tolerance: includes set up tolerance, line regulation, load regulation.
5. Line regulation is measured from low line to high line at rated load.
6. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time.
7. Derating may be needed under low input voltages. Pleas check the derating curve for more details.
8. The demand for Malaysia safety is processed with the order no. GST90A -SIRIM by request. Please contact MEAN WELL for details.
9. The power supply is considered as an independent unit, but the final equipment still need to re-confirm that the whole system complies with the
EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”
(as available on http://www.meanwell.com)
90WAC-DC High Reliability IndustrialAdaptor
GST90A15-P1MGST90A12-P1M GST90A19-P1M GST90A24-P1M GST90A48-P1M
GST90A15GST90A12
Note.2
Note.3
Note.4
Note.5
1000ms, 50ms / 230VAC 1000ms, 50ms / 115VAC at full load
Note.6
20ms / 230VAC 20ms / 115VAC at full load
Note.7
90 ~ 264VAC 127 ~ 370VDC
47 ~ 63Hz
PF>0.91 / 230VAC PF>0.95 / 115VAC at full load
89%
1.3A / 115VAC 0.6A/ 230VAC
Cold start 35 / 115AC
1mA / 240VAC
110 ~ 150% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
105 ~ 135% rated output voltage
Protection type : Shut down o/p voltage, re-power on to recover
Shut down o/p voltage, re-power on to recover
-30 ~ +70 (Refer to "Derating Curve")℃
20% ~ 90% RH non-condensing
-40 ~ +85 , 10 ~ 95% RH non-condensing℃
±℃℃0.03% / (0~40 )
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
UL , BSMI CNS14336, CCC GB4943.1, PSE J60950-1 ,62368-1, CSA C22.2 No.62368-1, TUV EN62368-1 ,AS/NZS 60950.1
BIS IS13252, KC K60950-1, approvedEAC TP TC 004 approved; SIRIM MS IEC60950-1 (optional)
I/P-O/P: 3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH℃
Parameter
Conducted emission
Radiated emission
Harmonic current
Voltage flicker
Parameter
ESD
RF field
susceptibility
EFT bursts
Surge susceptibility
Conducted susceptibility
Magnetic field
immunity
Voltage dips , interruption
348.7K hrs min. MIL-HDBK-217F(25 )℃
145*60*32mm (L*W*H)
0.45Kg; 30pcs/14.05Kg/1CUFT
4~5
See page ; Other type available by customer requested
See page ; Other type available by customer requested
4~5
15V12V
6A6.67A 4.74A 3.75A 1.87A
0 ~ 6A0 ~ 6.67A 0 ~ 4.74A 0 ~ 3.75A
90W80W 90W 90W 90W
150mVp-p120mVp-p 180mVp-p 200mVp-p 200mVp-p
±5.0%±5.0% ±4.0% ±3.0% ±2.5%
±1.0%±1.0% ±1.0% ±1.0% ±1.0%
±5.0%±5.0% ±4.0% ±3.0% ±2.5%
89.5%
70A / 230VAC
Standard
EN55032(CISPR32),FCC PART 15 / CISPR22
CAN ICES-3(B)/NMB-3(B),CNS13438,GB17625.1
EAC TP TC 020,MSIP KN32
EN55032(CISPR32),FCC PART 15 / CISPR22
CAN ICES-3(B)/NMB-3(B),CNS13438,GB17625.1
EAC TP TC 020,MSIP KN32
EN61000-3-2,GB9254
EN61000-3-3
Standard
EN61000-4-2
EN61000-4-3
EN61000-4-4
EN61000-4-5
EN61000-4-6
EN61000-4-8
EN61000-4-11
GST90A19
19V
90% 90% 91%
GST90A series
GST90A24
24V
Test Level / Note
Class B
Class B
Class A
-------
Test Level /Note
Level 4, 15KV air; Level 4, 8KV contact
Level 2, 3V/m
Level 2, 1KV
Level 3, 1KV/Line-Line , 2KV/Line-FG
Level 2, 3V
Level 2, 3A/m
>.95% dip 0 5 periods, 30% dip 25 periods,
95% interruptions 250 periods>
μ
μ
GST90A48
48V
0 ~ 1.87A
File Name:GST90A-SPEC 2019-11-08

90WAC-DC High Reliability IndustrialAdaptor
Derating Curve Static Characteristics
GST90A series
100
80
60
50
40
LOAD (%)
20
0-30 2010 30 40
AMBIENT TEMPERATURE ( )℃
Mechanical Specification
32
60
145
6050 70
(HORIZONTAL)
100
90
80
70
60
50
LOAD (%)
40
90 10095 120110 160140 200180 240220 264
INPUT VOLTAGE (VAC) 60Hz
Case No. GS90A Unit:mm
Ul1185 14AWG 1000 50mm for 12 ~ 15V±
UL1185 16AWG 1200 50mm for 19 ~ 48V±
70 10mm±
AC Inlet
IEC320-C14
DC output plug
◎ Standard plug: P1M◎
P1M
5.5
2.5
Power LED
11 0.5mm
±
Pin Assignment
C"+"
InsideOutside
-V not connected toAC FG
File Name:GST90A-SPEC 2019-11-08

◎ Optional DC plug:◎
90WAC-DC High Reliability IndustrialAdaptor
GST90A series
Tuning Fork Style
A
B
Barrel Style
A
B
Lock Style
A
B
SWITCHCRAFT original or equivalent
Locking
C
(Straight)
C
(Right-angled)
C
(Straight)
C
(Right-angled)
C
Type No.
A
B
OD ID
P1I 5.5 2.1 9.5
P1J
P1L
P1IR
P1JR
P1LR
P1MR
Type No.
5.5
5.5
5.5
5.5
5.5
5.5
A
2.1
2.5
2.1
2.1
2.5
2.5
B
OD ID
P2I
P2J
P2L
P2M
P2IR
P2JR
P2LR
P2MR
Type No.
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
A
2.1
2.1
2.5
2.5
2.1
2.1
2.5
2.5
B
OD ID
P2S(S761K)
P2K(761K)
P2C(S760K)
P2D(760K)
5.53
5.53
5.53
5.53
2.03
2.54
2.03
2.54
C
L
11.0
9.5
9.5
11.0
9.5
11.0
C
L
9.5
11.0
9.5
11.0
9.5
11.0
9.5
11.0
C
L
12.06
12.06
9.52
9.52
Center Pin Style
A
B
D
EIAJ equivalent
Min. DIN 3 Pin with Lock (male)
1
2
3
KYCON KPPX 3P equivalent-
Type No.
A
B
OD ID
C
P4A
P4B
P4C
Type No.
55.
6.5
7.4
3.4
4.4
5.1
Pin Assignment
PIN No.
1
R6B
2
3
C
L
11.0
11.0
11.0
Output
+Vo
-Vo
+Vo
File Name:GST90A-SPEC 2019-11-08
D
Center Pin
1.0
1.4
0.6

90WAC-DC High Reliability IndustrialAdaptor
GST90A series
Min. DIN 4 Pin with Lock (male)
2143
KYCON KPPX 4P equivalent-
Min. DIN 4 Pin with Lock (female)
3
2
4
1
KYCON KPJX-CM-4S equivalent
DIN 5 Pin (male)
3
1
5
4
2
Stripped and tinned leads
Type No.
R7B
Type No.
R7BF
Type No.
R1B
Type No.
Pin Assignment
PIN No.
1
2
3
4
Pin Assignment
PIN No.
1
2
3
4
Pin Assignment
PIN No.
1
2
3
4
5
Pin Assignment
PIN No.
Output
+Vo
-Vo
-Vo
+Vo
Output
+Vo
-Vo
-Vo
+Vo
Output
-Vo
-Vo
+Vo
-Vo
+Vo
Output
Length of Land L1 by request
( ’s standard length, L: mm, L1: mm)
MW
Installation Manual
Please refer to : http://www.meanwell.com/manual.html
25 5
L
(red)
1
1
+Vo
2
by customer
(black)
L1
2
-Vo
File Name:GST90A-SPEC 2019-11-08