280W AC-DC High Reliability Industrial Adaptor
THOMAS SAMUELTHOMAS SAMUEL
THOMAS SAMUELTHOMAS SAMUEL
GST280A series
IS13252 K60950-1 TPTC004 UL62368-1 EN62368-1 J60950-1 AS/NZS60950-1
GB4943.1 IEC62368-1MS IEC60950-1
(optional)
R33100
RoHS
■ Features ■ Applications
Global certificates
Universal AC input / Full range
3 pole AC inlet IEC320-C14,Class power unitⅠ
Built-in active PFC function
Consumer electronic devices
Telecommunication devices
Office facilities
Industrial equipments
No load power consumption<0.5W
Energy efficiency Level VI
Comply with EISA 2007/DoE,NRCan,AU/NZ MEPS,EU ErP
Protections: Short circuit / Overload / Over voltage /
Over temperature
Fanless design with -30~+70 working temperature℃
Fully enclosed plastic case
LED indicator for power on
3 years warranty
■ Description
GS T280A i s a highly reliable, 280W desktop style single-output green adaptor series. This product is a
Ⅰ
class power unit (with FG), equipped with a standard IEC320-C14 AC inlet and adopting the input range
from 85 VAC to 264VAC. The entire series supplies different models with output voltages ranging between
12VDC and 48VDC that can satisfy the demands for various types of consumer electronic devices.
With the efficiency up to 94% and the extremely low no-load power consumption below 0.5W, GST280A is
compliant with USA EISA 2007/DoE, Canada NRCan, Australia and New Zealand MEPS, EU ErP. Korea K-MEPS,
The supreme feature allows the adaptor to save the energy when it is either under the operating mode or the
standby mode. The entire series utilizes the 94V-0 flame retardant plastic case. GST280A is certified for
the international safety regulations.
■ Model Encoding
-A12GST C6P280
C6P: Standard model, 6 pin connector
DC connector type
Output voltage
IEC320-C14 AC inlet
Rated wattage
Series name
{
Other options available by customer requested (see Page 4)
File Name:GST280A-SPEC 2019-05-20

SPECIFICATION
ORDER NO.
SAFETY MODEL NO.
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
RATED POWER (max.)
OUTPUT
INPUT
PROTECTION
ENVIRONMENT
SAFETY &
EMC
(Note. 9)
OTHERS
CONNECTOR
NOTE
RIPPLE & NOISE (max.)
VOLTAGE TOLERANCE
LINE REGULATION Note.5
LOAD REGULATION
SETUP, RISE TIME
HOLD UP TIME (Typ.)
VO LTAGE RA NGE
FREQUENCY RANGE
POWER FACTOR (Typ.)
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
INRUSH CURRENT (max.)
LEAKAGE CURRENT(max.)
OVERLOAD
OVER VOLTAGE
OVER TEMPERATURE
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS Note. 8
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
EMC EMISSION
EMC IMMUNITY
MTBF
DIMENSION
PACKING
PLUG
CABLE
1. All parameters are specified at 230VAC input, rated load, 25 70% RH ambient. ℃
2. DC voltage: The output voltage set at point measure by plug terminal & 50% load.
3. Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1 f & 47 f capacitor.
4. Tolerance: includes set up tolerance, line regulation, load regulation.
5. Line regulation is measured from low line to high line at rated load.
6. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time.
7. Derating may be needed under low input voltage. Please check the derating curve for more details.
8. The demand for Malaysia safety is processed with the order no. GST280A -SIRIM by request. Please contact MEAN WELL for details.
9. The power supply is considered as an independent unit, but the final equipment still need to re-confirm that the whole system complies with the
EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”
(as available on http://www.meanwell.com)
280W AC-DC High Reliability Industrial Adaptor
GST280A12-C6P
GST280A12
Note.2
Note.3
Note.4
2000ms, 20ms / 230VAC 2000ms, 20ms / 115VAC at full load
Note.6
16ms / 230VAC 16ms / 115VAC at full load
Note.7
85 ~ 264VAC 120 ~ 370VDC
47 ~ 63Hz
PF>0.95 / 230VAC PF>0.98 / 115VAC at full load
89.5%
3A / 115VAC 1.5A / 230VAC
Cold start
95A / 115VAC 120A / 230VAC
1.5mA / 240VAC
105 ~ 135% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
105 ~ 135% rated output voltage
Protection type : Shut down o/p voltage, re-power on to recover
Shut down o/p voltage, re-power on to recover
-30 ~ +70 (Refer to "Derating Curve")℃
20% ~ 90% RH non-condensing
-40 ~ +85 , 10 ~ 95% RH non-condensing℃
±℃℃0.03% / (0~40 )
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
UL62368-1, CSA C22.2 No.62368-1, TUV EN62368-1, BSMI CNS14336, CCC GB4943.1, PSE J60950-1 ,,AS/NZS 60950.1
BIS IS13252, KC K60950-1, approvedEAC TP TC 004 approved; SIRIM MS IEC60950-1 (optional)
I/P-O/P: 3KVAC I/P-F/G: 2KVAC O/P-F/G: SHORT
I/P-O/P:100M Ohms / 500VDC / 25 / 70% RH℃
Parameter
Conducted emission
Radiated emission
Harmonic current
Voltage flicker
Parameter
ESD
RF field
susceptibility
EFT bursts
Surge susceptibility
Conducted susceptibility
Magnetic field
immunity
Voltage dips , interruption
181.24Khrs min. MIL-HDBK-217F(25 )℃
220*95*46mm (L*W*H)
1.25Kg; 12pcs/16Kg/1.27CUFT
See page ; Other type available by customer requested
4
4
See page ; Other type available by customer requested
GST280A15-C6P
GST280A15
GST280A20-C6P
GST280A20
15V12V 20V 24V 48V
17A21A 13A 11.67A 5.84A
0 ~ 17A0 ~ 21A 0 ~ 13A 0 ~ 11.67A
255W252W 260W 280.08W 280.32W
120mVp-p120mVp-p 150mVp-p 200mVp-p 200mVp-p
±5.0%±5.0% ±4.0% ±3.0% ±2.0%
±1.0%±1.0% ±1.0% ±1.0% ±1.0%
±5.0%±5.0% ±4.0% ±3.0% ±2.0%
90%
Standard
EN55032(CISPR32),FCC PART 15 / CISPR22
CAN ICES-3(B)/NMB-3(B),CNS13438,GB17625.1
EAC TP TC 020,MSIP KN32
EN55032(CISPR32),FCC PART 15 / CISPR22
CAN ICES-3(B)/NMB-3(B),CNS13438,GB17625.1
EAC TP TC 020,MSIP KN32
EN61000-3-2,GB9254
EN61000-3-3
Standard
EN61000-4-2
EN61000-4-3
EN61000-4-4
EN61000-4-5
EN61000-4-6
EN61000-4-8
EN61000-4-11
92% 93% 94%
μ
GST280A series
GST280A24-C6P
GST280A24
Test Level / Note
Class B
Class B
Class A
-------
Test Level /Note
Level 4, 15KV air; Level 4, 8KV contact
Level 2, 3V/m
Level 2, 1KV
Level 3, 1KV/Line-Line , 2KV/Line-FG
Level 2, 3V
Level 2, 3A/m
>.95% dip 0 5 periods, 30% dip 25 periods,
95% interruptions 250 periods>
μ
GST280A48-C6P
GST280A48
0 ~ 5.84A
File Name:GST280A-SPEC 2019-05-20

280W AC-DC High Reliability Industrial Adaptor
Derating Curve Static Characteristics
GST280A series
100
80
60
50
40
LOAD (%)
20
0-30
2010 30 35 40
AMBIENT TEMPERATURE ( )℃
Mechanical Specification
46 220
95
Others
110VAC for
12V~15V
100
90
80
70
60
50
LOAD (%)
40
70
6050
(HORIZONTAL)
85 10090 120110 160140 200180 240220 264
For others
For 12V~15V
INPUT VOLTAGE (VAC) 60Hz
Case No. GS280A Unit:mm
Power LED
UL2464 16AWGx4C 1000 50mm±
50 3mm±
AC Inlet
IEC320-C14
DC output plug
◎ Standard plug: C6P : MOLEX 39-01-2060 equivalent◎
C6P
Pin Assignment
PIN NO.
654
321
-V connected to AC FG
654
321
1,2,3
4,5,6
OUTPUT
+Vo
-Vo
File Name:GST280A-SPEC 2019-05-20

◎ Optional DC plug:◎
280W AC-DC High Reliability Industrial Adaptor
GST280A series
Min. DIN 4 Pin with Lock (female)
3
2
4
1
KYCON KPJX-CM-4S equivalent
NEUTRIK XLR NC4FX equivalent
4
1
3
2
AMP 1-480702-0 (6.35mm) equivalent
4
3
2
1
Type No.
R7BF
Type No.
MIC4
Type No.
C4P
Pin Assignment
PIN No.
1
2
3
4
Pin Assignment
PIN No.
1
2
3
4
Pin Assignment
PIN No.
1
2
3
4
Output
+Vo
-Vo
-Vo
+Vo
Output
+Vo
+Vo
-Vo
-Vo
Output
+Vo
+Vo
-Vo
-Vo
Installation Manual
Please refer to : http://www.meanwell.com/manual.html
File Name:GST280A-SPEC 2019-05-20