Mean Well LRS-50-3.3, LRS-50-24, LRS-50-5, LRS-50-12, LRS-50-15 User guide

...
Page 1
R33100
RoHS
S
&
E
LRS-50 series
Bauar
tgepruft
Sicherheit
egel gema od
os
be
wac g
www.
tuv.com
ID 2000000000
■ Features ■ Applications
Industrial automation machinery
Universal AC input / Full rangeWithstand 300VAC surge input for 5 secondNo load power consumption<0.2WMiniature size and 1U low profileHigh operating temperature up to 70℃Protections: Short circuit / Overload / Over voltage
 Industrial control systemMechanical and electrical equipmentElectronic instruments, equipments or
apparatus
Household appliances
Cooling by free air convectionCompliance to IEC/EN 60335-1(PD3) and
IEC/EN61558-1, -2-16 for household appliances
Operating altitude up to 5000 meters (Note.8)Withstand 5G vibration testHigh efficiency, long life and high reliabilityLED indicator for power onOver voltage category Ⅲ100% full load burn-in test3 years warranty
■ Description
LRS-50 series is a 50W single-output enclosed type power supply with 30mm of low profile design. Adopting the full range 85~264VAC input, the entire series provides an output voltage line of 3.3V, 5V, 12V, 15V, 24V, 36V and 48V. In addition to the high efficiency up to 90%, the design of metallic mesh case enhances the heat dissipation of LRS-50 that the whole series operates from -30 through 70 under air convection without a fan. ℃℃ Delivering an extremely low no load power consumption (less than 0.2W), it allows the end system to easily meet the worldwide energy requirement. LRS-50 has the complete protection functions and 5G anti­vibration capability; it is complied with the international safety regulations such as TUV EN60950-1,
EN60335-1,EN61558-1/-2-16, UL60950-1 and GB4943. LRS-50 series serves as a high price-to-
performance power supply solution for various industrial applications.
■ Model Encoding
LRS -- 50 3.3
Output voltage Rated wattage Series name
File Name:LRS-50-SPEC 2017-12-01
Page 2
SPECIFICATION
MODEL
DC VOLTAG E
RATED CURRENT
CURRENT RANGE
RATED POWER
RIPPLE & NOISE (max.)
OUTPUT VOLTAGE ADJ. RANGE
VOLTAGE TOLERANCE
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
HOLD UP TIME (Typ.)
VO LTAGE R ANGE
FREQUENCY RANGE
INPUT
PROTECTION
ENVIRONMENT
SAFETY & EMC
(Note 9)
OTHERS
NOTE
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
OVER LOAD
OVER VOLTAGE
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
OVER VOLTAGE CATEGORY
SAFETY STANDARDS
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
EMC EMISSION
EMC IMMUNITY
MTBF
DIMENSION
PACKING
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.℃
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Line regulation is measured from low line to high line at rated load.
5. Load regulation is measured from 0% to 100% rated load.
6. Length of set up time is measured at cold first start. Turning ON/OFF the power supply very quickly may lead to increase of the set up time.
7. 3.3V,5V when the load factor 0~50%, the switching power less is reduced by burst operation, which will cause ripple and ripple noise to go beyond the specifications.
8. The ambient temperature derating of 5 /1000m is needed for operating altitude greater than 2000m(6500ft).
9. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a mm* mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets 360 360 EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies. (as available on http://www.meanwell.com)
LRS-50 series
LRS-50-3.3 LRS-50-5 LRS-50-12 LRS-50-15 LRS-50-24 LRS-50-36 LRS-50-48
3.3V
10A
0 ~ 10A
33W
Note.2
80mVp-p
2.97 ~ 3.6V
Note.3
±3.0%
Note.4
±0.5%
Note.5
±2.0%
1000ms, 30ms/230VAC 2000ms,30ms/115VAC at full load
30ms/230VAC 12ms/115VAC at full load
85 ~ 264VAC 120 ~ 373VDC
47 ~ 63Hz
80%
0.95A/115VAC 0.56A/230VAC
COLD START 45A/230VAC
<0.75mA / 240VAC
110 ~ 150% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
3.8 ~ 4.45V 5.9~ 7.3V 13.8 ~ 16.2V 18.75 ~ 21.75V 28.8 ~ 33.6V 41.4 ~ 48.6V 55.2 ~ 64.8V
Protection type : Shut down o/p voltage, re-power on to recover
-30 ~ +70℃ (Refer to "Derating Curve")
20 ~ 90% RH non-condensing
-40 ~ +85 , 10 ~ 95% RH non-condensing℃
±℃ ℃0.03%/ (0 ~ 50 )
10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes
Ⅲ; Compliance to EN61558, EN50178, EN60664-1, EN62477-1; altitude up to 2000 meters
UL60950-1, TUV EN60950-1, EN60335-1, EN61558-1 2 16 .1, BSMI CNS14336-1,/- - ,CCC GB4943 EAC TPTC 004,AS/NZS 60950.1(by CB) approved
I/P-O/P:4KVAC I/P-FG:2KVAC O/P-FG:1.25KVAC I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH℃
Compliance to EN55032 (CISPR32) Class B, EN55014, EN61000-3-2,-3, GB/T 9254, BSMI CNS13438, EAC TP TC 020
Compliance to EN61000-4-2,3,4,5,6,8,11, EN61000-6-2 (EN50082-2), heavy industry level, criteriaA, EAC TPTC 020 645K hrs min. MIL-HDBK-217F (25 )℃
99*82*30mm (L*W*H)
0.23Kg; 60pcs/14.8Kg/0.88CUFT
5V
10A
0 ~ 10A
50W
80mVp-p
4.5 ~ 5.5V
±2.0% ±0.5% ±1.0%
83%
℃
12V
4.2A
0 ~ 4.2A
50.4W
120mVp-p
10.2 ~ 13.8V
±1.0% ±0.5% ±0.5%
86%
15V
3.4A
0 ~ 3.4A
51W
120mVp-p
13.5 ~ 18V
±1.0% ±0.5% ±0.5%
88%
24V
2.2A
0 ~ 2.2A
52.8W
150mVp-p
21.6 ~ 28.8V
±1.0% ±0.5% ±0.5%
88%
36V
1.45A
0 ~ 1.45A
52.2W
200mVp-p
32.4 ~ 39.6V
±1.0% ±0.5% ±0.5%
89%
48V
1.1A
0 ~ 1.1A
52.8W
200mVp-p
43.2 ~ 52.8V
±1.0% ±0.5% ±0.5%
90%
File Name:LRS-50-SPEC 2017-12-01
Page 3
LRS-50 series
Block Diagram
I/P
FG
FILTER
Derating Curve
100VAC Input only
230VAC
100
75
60
40
LOAD (%)
20
-30 0-25 2010 30 40
EMI
100VAC for 5V
RECTIFIERS
&
FILTER
6050
O.L.P.
70
SWITCHING
(HORIZONTAL)
POWER
O.V.P.
CONTROL
Static Characteristics
100
90
80
70
60
50
LOAD (%)
40
85 10095 120115 160140 200180 240220 264
RECTIFIERS
&
FILTER
DETECTION
CIRCUIT
fosc : 115Vac : 75KHz
230Vac :110KHz
+V
-V
AMBIENT TEMPERATURE ( )℃
INPUT VOLTAGE (VAC) 60Hz
File Name:LRS-50-SPEC 2017-12-01
Page 4
LRS-50 series
Mechanical Specification
4.5
ψ3.5
9.5
8
26
1
2
2-M3 L=3.0
3
4
5
20.5 55
6.5
ψ3.5
15
10
74
92.5
99
Case No.239A Unit:mm
82
70
40.5
90
3.5
6.5
Terminal Pin No. Assignment
Pin No. Pin No.
Assignment Assignment 1 2 3
AC/L AC/N
FG
4 5
DC OUTPUT -V DC OUTPUT +V
3.5
2-M3 L=5
30
14.5
Installation Manual
Please refer to : http://www.meanwell.com/manual.html
File Name:LRS-50-SPEC 2017-12-01
Loading...