360W Level Desktop Type Power SupplyⅥ
TPTC004 IEC62368-1UL62368-1
ENP-360 series
■ Features ■ Applications
Universal AC input / Full range
Built-in active PFC function
Energy efficiency Level Ⅵ
Land mobile radio system
Surveillance system
TV antenna facility
No load power consumption <0.5W
Comply with EISA 2007/DoE, NRCan and EU ErP
125% peak load capability
Fanless design, cooling by free air convection
Protection: Short circuit / Overload / Over voltage /
Over temperature
3 years warranty
■ Description
ENP-360 series is a 36 0W desktop type power supply working perfectly for communication related
applications. Observing the standard 7 width size in the land mobile radio field, it provides the most
frequently used voltage in the communication field. With the rugged mechanical design along with the
high efficiency circuitry, it operates for the ambient temperature range -30 ~+70 under free air convection. ℃℃
■ Model Encoding
ENP -- 360 24
Nominal voltage
Rated wattage
Series name
File Name:ENP-360-SPEC 2020-03-09

SPECIFICATION
MODEL
DC VO LTAG E
RATED CURRENT
CURRENT
WATTAGE
OUTPUT
INPUT
PROTECTION
ENVIRONMENT
SAFETY &
EMC
(Note 9)
NOTE
RIPPLE & NOISE (max.)
VOLTAGE ADJ. RANGE
VOLTAGE TOLERANCE Note.4
LINE REGULATION Note.5
LOAD REGULATION Note.6
SETUP, RISE TIME Note.7
HOLD UP TIME (Typ.)
VOLTAGE RANGE
FREQUENCY RANGE
POWER FACTOR (Typ.)
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
NO LOAD POWER CONSUMPTION
SHORT CIRCUIT
OVERLOAD
OVER VOLTAGE
OVER TEMPERATURE
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
EMC EMISSION
EMC IMMUNITY
MTBF
DIMENSIONOTHERS
PACKING
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.℃
2. Peak current or peak power up to 3 seconds is provided.
3. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
4. Tolerance : includes set up tolerance, line regulation and load regulation.
5. Line regulation is measured from low line to high line at rated load.
6. Load regulation is measured from 0% to 100% rated load.
7. Length of set up time is measured at cold first start. Turning ON/OFF the power supply very quickly may lead to increase of the set up time.
8. Derating may be needed under low input voltages. Please check the derating curve for more details.
9. The power supply is considered as an independent unit, but the final equipment still need to re-confirm that the whole system complies with the
EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies.
(as available on http://www.meanwell.com)
10. The ambient temperature derating of 3.5 /1000m with fanless models and of 5 /1000m with fan models for operating altitude higher than 2000m(6500ft).℃℃
360W Level Desktop Type Power SupplyⅥ
RATED
PEAK Note.2
RATED
PEAK Note.2
359W
450W
Note.3
11.5 ~ 15V 23.5 ~ 30V 47.5 ~ 58.8V
1000ms, 100ms at full load
20ms at full load
Note.8
90 ~ 264VAC 127 ~ 370VDC
47 ~ 63Hz
PF>0.98/115VAC, PF>0.95/230VAC at full load
3.8A/115VAC 1.9A/230VAC
COLD START 60Aat 230VAC
<3.5mA / 240VAC
<0.5W
Protection type : Constant current limiting, recovers automatically after fault condition is removed
Normally works within 110 ~ 125% rated output power for more than 3 seconds and switches to constant current limiting, with
auto-recovery after the peak load condition is removed
Constant current limiting, if >125% rated power, with auto-recovery after the overload condition is removed
15.5 ~ 18.2V
Protection type : Shut down o/p voltage, re-power on to recover
Shut down O/P voltage, recovers automatically after temperature goes down
-30 ~ +70 (Refer to "Derating Curve")℃
20 ~ 95% RH non-condensing
-40 ~ +85 , 10 ~ 95% RH non-condensing℃
±℃ ℃0.05%/ (0 ~ 50 )
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
IEC62368-1, UL62368-1 EAC TPTC 004 approved
I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH℃
Parameter
Conducted
Radiated
Harmonic Current
Voltage Flicker
EN55024
Parameter
ESD
Radiated
EFT / Burst
Surge
Conducted
Magnetic Field
Voltage Dips and Interruptions
147.5K hrs min. MIL-HDBK-217F (25 )℃
192*178*45.5mm (L*W*H)
1.5Kg; 10pcs/16Kg /1.38CUFT
ENP-360 series
ENP-360-24 ENP-360-48ENP-360-12
27.6V 55.2V13.8V
13A 6.5A26A
0 ~ 13A 0 ~ 6.5A0 ~ 26A
16.3A 8.2A32.6A
359W
450W
150mVp-p 350mVp-p150mVp-p
±1.0% ±1.0%±1.0%
±0.5% ±0.5%±0.5%
±1.0% ±0.5%±2.0%
93% 94%91%
31 ~ 36.5V 62.1 ~ 72.9V
,
Standard
EN55032 (CISPR32) / FCC PART15 (CISPR22)
EN55032 (CISPR32) / FCC PART15 (CISPR22)
EN61000-3-2
EN61000-3-3
Standard
EN61000-4-2
EN61000-4-3
EN61000-4-4
EN61000-4-5
EN61000-4-6
EN61000-4-8
EN61000-4-11
359W
453W
Test Level / Note
Class B
Class B
-----
-----
Test Level / Note
Level 3, 8KV air ; Level 2, 4KV contact
Level 2, 3V/m
Level 2, 1KV
Level 2, 1KV/Line-Line,Level 3, 2KV/Line-Earth
Level 2, 3Vrms
Level 1, 1A/m
>95% dip 0.5 periods, 30% dip 25 periods,
>95% interruptions 250 periods
File Name:ENP-360-SPEC 2020-03-09

Block Diagram
360W Level Desktop Type Power SupplyⅥ
ENP-360 series
LOAD (%)
FG
EMI FILTER
I/P
&
RECTIFIERS
PFC
CIRCUIT
PFC
CONTROL
POWER
SWITCHING
O.L.P.
PWM
CONTROL
RECTIFIERS
&
FILTER
CONSTANT
CURRENT
LIMITING &
DETECTION
CIRCUIT
O.V.P.
+V
-V
Static CharacteristicsDerating Curve
LOAD (%)
100
90
80
70
60
50
40
100
80
60
40
20
-30 0 2010 30 40
AMBIENT TEMPERATURE ( )
℃
6050
70 (HORIZONTAL)
90 100 115 120 140 160 180 190 200 220 240 264
INPUT VOLTAGE (V) 60Hz
File Name:ENP-360-SPEC 2020-03-09

360W Level Desktop Type Power SupplyⅥ
ENP-360 series
Mechanical Specification
TB1
1
2
3
4
VR
INLET
192
Case No. 252 Unit:mm
45.5
50
47.5
2 M3 L=5-
78
178
SWITCH
4.3
LED
Terminal Pin No. Assignment (TB1):
Pin No.
1,2
3,4
Installation Manual
Please refer to : http://www.meanwell.com/manual.html
Assignment
+V
-V
File Name:ENP-360-SPEC 2020-03-09