MEANWELL ELG-100-24AB-3Y Datasheet

Page 1
70~100W Constant Voltage + Constant Current LED Driver
110
(for DA-Type only)
MM
SELV
IP65
IP67
Type HL
Features ApplicationsConstant Voltage + Constant Current mode output
Metal housing design with functional GroundBuilt-in active PFC functionClass 2 power unit <0.5WNo load / Standby power consumptionIP67 / IP65 rating for indoor or outdoor installations
LED street lightingLED architectural lightingLED bay lightingLED floodlightingType HL for use in Class I, Division 2
hazardous (Classified) location.
Function options: output adjustable via potentiometer;
3 in 1 dimming (dim-to-off); Smart timer dimming; DALI
Typical lifetime>50000 hours5 years warranty
ELG-100 series
IS 15885(Part 2/Sec13)
THOMAS SAMUEL
THOMAS SAMUEL
R-41027766
(for 24/24B/36/36A/42/42A/48/48B/54/54Aonly)
Description
ELG-100 series is a 100W AC/DC LED driver featuring the dual mode constant voltage and constant current output. ELG-100 operates from 100 360VAC and offers models with different rated voltage ranging between 24V and 54V. Thanks to the high efficiency up to 91%, with the fanless design, the entire series is able to operate for -40 ~ +90 case temperature under℃℃ free air convection. The design of metal housing and IP67/IP65 ingress protection level allows this
series to fit both indoor and outdoor applications. ELG-100 is equipped with various function options, such as dimming methodologies, so as to provide the optimal design flexibility for LED lighting system
Model Encoding
Type
Blank
A
B
AB IP65
DA
Dx
D2
IP Level
IP67 IP65 IP67
IP67 IP67 IP67
-36ELG - 100
Io and Vo fixed.
Io adjustable through built-in potentiometer.and Vo 3 in 1 dimming function (0~10Vdc, 10V PWM signal and resistance) Io and Vo adjustable through built-in potentiometer &
3 in 1 dimming function (0~10Vdc, 10V PWM signal and resistance) DALI control technology. Built-in Smart timer dimming function by user request. Built-in Smart timer dimming and programmable function.
A
-
Input wiring type
Function mode option
Rated output voltage(24/36/42/48/54V) Rated wattage
Series name
Function Note
Blank:2-wire input for standard model
{
3Y:3-wire input for standard model
File Name:ELG-100-SPEC 2018-09-30
In Stock In Stock In Stock
In Stock
In Stock
By request
In Stock
Page 2
SPECIFICATION
MODEL
DC VOLTAGE
CONSTANT CURRENT REGION
RATED CURRENT
RATED POWER
RIPPLE & NOISE (max.)
VOLTAGE ADJ. RANGE
OUTPUT
CURRENT ADJ. RANGE
VOLTAGE TOLERANCE
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
HOLD UP TIME (Typ.)
VOLTAGE RANGE
FREQUENCY RANGE
POWER FACTOR
TOTAL HARMONIC DISTORTION
INPUT
PROTECTION
ENVIRONMENT
SAFETY &
EMC
NOTE
EFFICIENCY (Typ.)
AC CURRENT
INRUSH CURRENT(Typ.)
MAX. No. of PSUs on 16A CIRCUIT BREAKER
LEAKAGE CURRENT
NO LOAD / STANDBY POWER CONSUMPTION
OVER CURRENT
SHORT CIRCUIT
OVER VOLTAGE
OVER TEMPERATURE
WORKING TEMP.
MAX. CASE TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
DALI STANDARDS
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
EMC EMISSION
EMC IMMUNITY MTBF
DIMENSIONOTHERS
PACKING
1. All parameters NOT specially mentioned are measured at 230VAC input, rated and 25 of ambient temperature.current
2. Please refer to "DRIVING METHODS OF LED MODULE". For DA-Type, Constant Current region is 60%~100% of maximum voltage under rated power delivery.
3. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
4. Tolerance : includes set up tolerance, line regulation and load regulation.
5. De rating may be needed under low input voltages. Please .- refer to STATIC CHARACTERISTIC sections for details
6. Length of set up time is measured at first cold start. Turning ON/OFF the driver may lead to increase of the set up time.
7. The driver is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
8. This series meets the typical life expectancy of >50,000 hours of operation when Tcase, particularly tc point (or TMP, per DLC), is about 80 or less.
9. Please refer to the warranty statement on MEAN WELL's website at http://www.meanwell.com
10.The ambient temperature derating of 3.5 /1000m with fanless models and of 5 /1000m with fan models for operating altitude higher than 2000m(6500ft).℃℃
11. For any application note and IP water proof function installation caution, please refer our user manual before using.
https://www.meanwell.com/Upload/PDF/LED_EN.pdf
70~100W Constant Voltage + Constant Current LED Driver
ELG-100-42
42V
21 ~ 42V
2.28A
95.76W
70W
250mVp-p
37.8 ~ 46.2V
1.14 ~ 2.28A
±2.5%
±0.5% ±0.5%
90%
47 ~ 54V
IEC/EN/AS/NZS 61347-1, IEC/EN/AS/NZS 61347-2-13
GB17743, GB17625.1 ,C KN15 KN61547
Note.6
Note.5
ELG-100-24
24V
12 ~ 24V
Note.2
4.0A
200VAC ~ 305VAC
96W
100VAC ~ 180VAC
70W
200mVp-p
Note.3
Adjustable for A/AB-Type only (via the built-in potentiometer)
21.6 ~ 26.4V
Adjustable for A/AB-Type only (via the built-in potentiometer)
2 ~ 4A ±3.0%
Note.4
±0.5% ±1.0%
1000ms, 80ms/115VAC 500ms, 100ms/230VAC
15ms/115VAC 10ms/230VAC
ELG-100-36
36V
18 ~ 36V
2.66A
95.76W
70W
250mVp-p
32.4 ~ 39.6V
1.33 ~ 2.66A
±2.5%
±0.5% ±1.0%
100 ~ 305VAC 142 ~ 431VDC continue,320VAC for 24Hrs; 360VAC for 1Hr
(Please refer to "STATIC CHARACTERISTIC" section)
47 ~ 63Hz
PF 0.97/115VAC, PF 0.95/230VAC, PF 0.92/277VAC@full load≧≧≧ (Please refer to "POWER FACTOR (PF) CHARACTERISTIC" section)
THD< 20%(@load 50%/115VC; @load 60%/230VAC; @load 75%/277VAC)≧≧ ≧ (Please refer to “TOTAL HARMONIC DISTORTION(THD)” section)
88%
1.1A / 115VAC 0.6A / 230VAC 0.5A/277VAC
COLD START 60A(twidth=850 s measured at 50% Ipeak) at 230VACμ;Per NEMA410
3 units (circuit breaker of type B) / 6 units (circuit breaker of type C) at 230VAC
<0.75mA / 277VAC
No load power consumption <0.5W for Blank /A/ Dx / D2-Type Standby power consumption <0.5W for B / AB / DA-Type
95 ~ 108%
Constant current limiting, recovers automatically after fault condition is removed
Hiccup mode, recovers automatically after fault condition is removed
28 ~ 34V
Shut down output voltage, re-power on to recover
Shut down output voltage, re-power on to recover
Tcase=-40 ~ +90 (Please refer to “ OUTPUT LOAD vs TEMPERATURE” section)
Tcase=+90 20 ~ 95% RH non-condensing
-40 ~ +80 , 10 ~ 95% RH
±℃ ℃0.03%/ (0 ~ 60 )
10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes
UL8750 ,
(type”HL”) CSA C22.2 No. 250.13-12; independent, EN62384;
EAC TPTC 004;BIS IS15885(for 24/24B/36/36A/42/42A/48/48B/54/54Aonly); KC61347-1 KC61347-2-13,
Compliance to IEC62386-101, 102, 207 for DA-Type only
I/P-O/P:3.75KVAC I/P-FG:2.0KVAC O/P-FG:1.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
Compliance to
Compliance to EN61000-4-2,3,4,5,6,8,11; EN61547, light industry level ( )surge immunity Line-Earth 6KV, Line-Line 4KV
978.2K hrs min. Telcordia SR-332 (Bellcore) 282.9Khrs min. MIL-HDBK-217F (25 )
199 63* *35.5mm (L*W*H)
EN55015
89%
41 ~ 48V
approved
,EN61000-3-2 Class C (@load 60%); EN61000-3-3;
0.85kg; 16pcs/14.2kg/0.72CUFT
ELG-100 series
ELG-100-48
48V
24 ~ 48V
2A
96W
70W
300mVp-p
43.2 ~ 52.8V
1 ~ 2A
±2.0%
±0.5% ±0.5%
90%
54 ~ 62V
ELG-100-54
54V
27 ~ 54V
1.78A
96.12W
70W
350mVp-p
48.6 ~ 59.4V
0.89 ~ 1.78A
±2.0%
±0.5% ±0.5%
91%
62 ~ 72V
; IP65 or IP67;GB19510.1, GB19510.14
;EAC TP TC 020; K
;EAC TP TC 020; KC KN15 KN61547,
File Name:ELG-100-SPEC 2018-09-30
Page 3
Block Diagram
70~100W Constant Voltage + Constant Current LED Driver
ELG-100 series
PFC fosc : 50~120KHz
PWM fosc : 60~130KHz
I/P
EMI FILTER
&
RECTIFIERS
PFC
CIRCUIT
O.L.P.O.T.P.
CASE :Protective Earth
POWER
SWITCHING
PWM & P FC
CONTROL
DRIVING METHODS OF LED MODULE
This series is able to work in either Constant Current mode (a direct drive way) or
Constant Voltage mode (usually through additional DC/DC driver) to drive the LEDs.
100
Vo(%)
50
(min.)
(A)
Constant
V areaoltage
(B)
Constant
Current area
(C)
Hiccup
Protection
In the constant current region, the highest voltage at the output of the driver depends on the configuration of the end systems.
Should there be any compatibility issues, please contact MEAN WELL.
RECTIFIERS
&
FILTER
Vo+ Vo-
O.L.P.
DETECTION
CIRCUIT
O.V.P.
50
Typical output current normalized by rated current (%)
This characteristic applies to Blank/A/B/AB/DX/D2-Type,
For DA-Type, the Constant Current area is 60%~100% Vo.
100
Io(%)
File Name:ELG-100-SPEC 2018-09-30
Page 4
70~100W Constant Voltage + Constant Current LED Driver
DIMMING OPERATION
ELG-100 series
AC/N(Blue) AC/L(Brown)
ELG-100
3 in 1 dimming function (for B/AB-Type)
Output constant current level can be adjusted by applying one of the three methodologies between DIM+ and DIM-:
0 ~ 10VDC, or 10V PWM signal or resistance.
Direct connecting to LEDs is suggested. It is not suitable to be used with additional drivers. Dimming source current from power supply: 100 A (typ.) μ
Applying additive 0 ~ 10VDC
+
Vo+
-
Vo-
DIM+
DIM-
DO NOT connect "DIM- to Vo-"
+
Additive Voltage
-
+
-
Applying additive 10V PWM signal (frequency range 100Hz ~ 3KHz):
+
Vo+
-
Vo-
DIM+
DIM-
DO NOT connect "DIM- to Vo-"
Additive PWM signal
+
-
100%
90%
80%
70%
60%
50%
40%
Output current (%)
30%
20%
10%
0%
0V 1V 2V 3V 4V 5V 6V 7V 8V 9V 10V
Dimming input:Additive voltage
100%
90%
80%
70%
60%
50%
40%
Output current (%)
30%
20%
10%
0%
0%
10% 20% 30% 40% 50% 60% 70% 80% 90% 100%
Duty cycle of additive 10V PWM signal dimming input
DIM+( )*Blue DIM-(White)**
Vo-(Black) Vo+(Red)
* DIM + for B/A B-Type
DA+ for DA-Type PROG+ for D2-Type
* *DIM- for B/AB-Type
DA- for DA-Type PROG- for D2-Type
Applying additive resistance:
+
Vo+
-
Vo-
DIM+
DIM-
DO NOT connect "DIM- to Vo-"
Additive Resistance
+
-
Note : 1. Min. dimming level is about 8% and the output current is not defined when 0%< out<8%.I
2. The output current could drop down to 0% when dimming input is about 0k or 0Vdc, or 10V PWM signal with 0% duty cycle.Ω
100%
90%
80%
70%
60%
50%
40%
Output current (%)
30%
20%
10%
0%
Short
10K/N 20K/N 30K/N 40K/N 50K/N 60K/N 70K/N 80K/N 90K/N 100K/N
(N=driver quantityfor synchronized )dimming operation
Dimming input:Additive resistance
File Name:ELG-100-SPEC 2018-09-30
Page 5
70~100W Constant Voltage + Constant Current LED Driver
DAL Interface (primary side; for DA-Type)IApply DALI signal between DA+ and DA-.
DAL protocol comprises 16 groups and 64 addresses. I First step is fixed at 8% of output.
Smart timer dimming function (for Dxx-Type by User definition)
MEAN WELLSmart timer dimming primarily provides the adaptive proportion dimming profile for the output constant current level to perform up to 14 consecutive hours. 3 dimming profiles hereunder are defined accounting for the most frequently seen applications. If other options may be needed, please contact MEAN WELL for details.
Ex : D01-Type: the profile recommended for residential lighting
Set up for D01-Type in Smart timer dimming software program:
ELG-100 series
T1
TIME**
LEVEL**
Dimming Level(%)
Operating Time(HH:MM)
**: TIME matches Operating Time in the diagram whereas LEVELmatches Dimming Level.
Example: If a residential lighting application adopts D01-Type, when turning on the power supply at 6:00pm, for instance: [1] The power supply will switch to the constant current level at 100% starting from 6:00pm. [2] The power supply will switch to the constant current level at 70% in turn, starting from 0:00am, which is 06:00 after the power supply turns on. [3] The power supply will switch to the constant current level at 50% in turn, starting from 1:00am, which is 07:00 after the power supply turns on. [4] The power supply will switch to the constant current level at 70% in turn, starting from 5:00am, which is 11:00 after the power supply turns on.
The constant current level remains till 8:00am, which is 14:00 after the power supply turns on.
Ex: D02-Type: the profile recommended for street lighting
Set up for D02-Type in Smart timer dimming software program:
06:00
100% 70%
T1
T2
T2
07:00
T3
T3
11: 00
50%
T4
---
70%
T4 T5
TIME**
LEVEL**
Dimming Level(%)
Operating Time(HH:MM)
**: TIME matches Operating Time in the diagram whereas LEVELmatches Dimming Level. Example: If a street lighting application adopts D02-Type, when turning on the power supply at 5:00pm, for instance: [1] The power supply will switch to the constant current level at 50% starting from 5:00pm. [2] The power supply will switch to the constant current level at 80% in turn, starting from 6:00pm, which is 01:00 after the power supply turns on. [3] The power supply will switch to the constant current level at 100% in turn, starting from 8:00pm, which is 03:00 after the power supply turns on. [4] The power supply will switch to the constant current level at 60% in turn, starting from 1:00am, which is 08:00 after the power supply turns on. [5] The power supply will switch to the constant current level at 80% in turn, starting from 4:00am, which is 11:00 after the power supply turns on. The
constant current level remains till 6:30am, which is 14:00 after the power supply turns on.
01:00
03:00
80%50%
8:00 11:00
100%
60% 80%
File Name:ELG-100-SPEC 2018-09-30
---
Page 6
Ex: D03-Type: the profile recommended for tunnel lighting
70~100W Constant Voltage + Constant Current LED Driver
Set up for D03-Type in Smart timer dimming software program:
T1 T2 T3
ELG-100 series
TIME** 01:30
Dimming Level(%)
Operating Time(HH:MM)
**: TIME matches Operating Time in the diagram whereas LEVELmatches Dimming Level. Example: If a tunnel lighting application adopts D03-Type, when turning on the power supply at 4:30pm, for instance: [1] The power supply will switch to the constant current level at 70% starting from 4:30pm. [2] The power supply will switch to the constant current level at 100% in turn, starting from 6:00pm, which is 01:30 after the power supply turns on. [3] The power supply will switch to the constant current level at 70% in turn, starting from 5:00am, which is 11:00 after the power supply turns on. The constant current level remains till 6:30am, which is 14:00 after the power supply turns on.
LEVEL** 70% 100% 70%
11:00 ---
File Name:ELG-100-SPEC 2018-09-30
Page 7
80
82
84
86
88
90
92
94
50% 60% 70% 80% 90% 100%
277V(100W)
230V(100W)
115V(80W)
70~100W Constant Voltage + Constant Current LED Driver
2%
4%
6%
8%
10%
12%
14%
16%
18%
20%
22%
50% 60% 70% 80% 90% 100%
277VAC(100W)
230VAC(100W)
115VAC(70W)
0.86
0.88
0.9
0.92
0.94
0.96
0.98
1
50% 60% 70% 80% 90% 100%
277V(100W)
230V(100W)
115V(70W)
OUTPUT LOAD vs TEMPERATURE(Note.9)
ELG-100 series
100
80
230VAC
input only
60
40
20
LOAD (%)
-40 -25 0-10 15 30 50 60 70
AMBIENT TEMPERATURE,Ta ( )
STATIC CHARACTERISTIC
100
90
80
70
60
50
LOAD (%)
40
(HORIZONTAL)
100
80
230VAC
input only
60
40
20
LOAD (%)
-40-250 103050708590
Tcase ( )
POWER FACTOR (PF) CHARACTERISTIC
Tcase at 80
Constant Current Mode
PF
(HORIZONTAL)
100 120 140 160 180 200 240 250 260 270 280 305
INPUT VOLTAGE (V) 60Hz
De-rating is needed under low input voltage.
TOTAL HARMONIC DISTORTION (THD)
54V Model, Tcase at 80
THD
LOAD
LOAD
EFFICIENCY vs LOAD
ELG-100 series possess superior working efficiency that up to 91% can be reached in field applications.
54V Model, Tcase at 80
EFFICIENCY(%)
LOAD
File Name:ELG-100-SPEC 2018-09-30
(100W)
(100W)
(70W)
Page 8
0
20
40
60
80
100
120
20 30 40 50 60 70 80 90
LIFE TIME
70~100W Constant Voltage + Constant Current LED Driver
LIFETIME(Kh)
Tc a s e )(
ELG-100 series
File Name:ELG-100-SPEC 2018-09-30
Page 9
70~100W Constant Voltage + Constant Current LED Driver
Mechanical SpecificationMechanical Specification
Blank-Type
AC/N(Blue)
AC/L(Brown)
SJOW 17AWGx2C &H05RN-F 1.0mm
300±20
ELG-100 series
CASE NO.: 244A Unit:mm
199 188
175
63
45.8
2
4- 4.5ψ
tc
: Max. CaseTemperature
tc
20
105
300±20
SJOW 17AWGx2C &05RN-F 1.0mm
35
35.5
Vo-(Black) Vo+(Red)
2
A-Type
AC/L(Brown)
AC/N(Blue)
300±20
SJOW 17AWGx2C &H05RN-F 1.0mm
199 188
175
63
45.8
2
4- 4.5ψ
tc
: Max. CaseTemperature
tc
20
105
300±20
SJOW 17AWGx2C &05RN-F 1.0mm
35
35.5
21.5
Vo-(Black) Vo+(Red)
2
33
14
File Name:ELG-100-SPEC 2018-09-30
Page 10
AB-Type
70~100W Constant Voltage + Constant Current LED Driver
199
300±20
188
175
ELG-100 series
300±20
B DA/D2-Type/
AC/N(Blue)
AC/L(Brown)
SJOW 17AWGx2C &H05RN-F 1.0mm
33
UL2517 20AWGx2C
SJOW 17AWGx2C &05RN-F 1.0mm
35
35.5
21.5
2
63
45.8
2
4- 4.5ψ
tc
: Max. CaseTemperature
tc
20
105
14
DIM+( )Blue DIM-(White)
Vo-(Black) Vo+(Red)
AC/N(Blue)
AC/L(Brown)
300±20
SJOW 17AWGx2C &H05RN-F 1.0mm
199 188
175
63
45.8
2
4- 4.5ψ
tc
: Max. CaseTemperature
tc
20
105
300±20
UL2517 20AWGx2C
SJOW 17AWGx2C &05RN-F 1.0mm
35
35.5
2
DIM+(Blue)* DIM-(White)**
Vo-(Black) Vo+(Red)
* DIM + for B-Ty pe
DA+ for DA-Type PROG+ for D2-Type
* *DIM- for B-Type
DA- for DA-Type PROG- for D2-Type
File Name:ELG-100-SPEC 2018-09-30
Page 11
70~100W Constant Voltage + Constant Current LED Driver
3Y Model (3-wire input)
199
300±20
45.8
AC/N(Blue) AC/L(Brown) PE (Green/Yellow)
SJOW 17AWGx3C &H05RN-F 1.0mm
63
2
4- 4.5ψ
tc
: Max. CaseTemperature
Note1: Please connect the case to PE for the complete EMC deliverance and safety use.Note2: Please contact MEAN WELL for input wiring option with PE.
INSTALLATION MANUAL
Please refer to : http://www.meanwell.com/manual.html
188
175
tc
20
105
ELG-100 series
SJOW 17AWGx2C &05RN-F 1.0mm
2
File Name:ELG-100-SPEC 2018-09-30
Loading...