Meade TE923W-M User Manual

TE923W-M
PROFESSIONAL WEATHER STATION
WITH REMOTE CONTROL
USER MANUAL
1
MP12:5,80/11/4dmp.RLLEWYENOH)GNE(1MIW329ET 1
Table of Contents
Introduction ..............................................................................................
Rain Gauge ............................................................................................. 10
Anemometer (wind sensor) .................................................................... 12
Main Unit................................................................................................ 14
Battery installation.................................................................................. 15
Buttons and Controls .............................................................................. 15
Operating mode descriptions .................................................................. 18
Customizing your Weather Station ......................................................... 21
LED Backlight Options .......................................................................... 21
Connecting the Weather Station to a PC................................................. 21
Using Different Weather Modes ............................................................. 22
Pressure and Weather Forecast Mode ..................................................... 22
UV Mode ................................................................................................ 25
Clock and Alarm Mode .......................................................................... 25
Manual Settings ...................................................................................... 25
Sunrise/Sunset Mode .............................................................................. 29
Temperature and Humidity Mode ........................................................... 30
Rain Mode .............................................................................................. 32
Wind Mode ............................................................................................. 33
Maintenance............................................................................................ 34
Troubleshooting ...................................................................................... 35
PRECAUTIONS..................................................................................... 35
Appendix - City Codes ........................................................................... 36
Specifications ......................................................................................... 40
FCC STATEMENT ................................................................................. 42
DECLARATION OF CONFORMITY................................................... 42
STANDARD WARRANTY INFORMATION ....................................... 43
3
TE923W IM1(ENG) HONEYWELL R.pmd 4/11/08, 5:21 PM2
2
Introduction
Thank you for selecting the Meade Instruments TE923WD-M Professional Weather Station with remote control. This feature rich and easy-to-use product delivers a wide variety of time and weather data, such as precise atomic time, perpetual calendar, air temperature, relative humidity, barometric pressure, wind speed and direction, rainfall, UV levels and much more.
Meade Instruments is the world’s leading designer and manufacturer of telescopes for professional and amateur astronomers - famous for its innovative, high performance telescopes at affordable prices. Meade Instruments now brings that same passion innovation and high performance to its own line of precision, feature rich weather stations.
In this package you will find:
• One Main Unit (receiver) (TE923WD-M)
• One IR Remote Control (TS607-M)
• One Rain Gauge (remote rain sensor/transmitter) (TS906-M)
• One Anemometer (remote wind sensor/transmitter) (TS805-M)
• One UV (ultraviolet) sensor (remote ultraviolet sensor/transmitter) (TS704-M)
• One Five-Channel Temperature & Humidity Sensor (transmitter) (TS34C-M)
• One CD disk with generic PC connection software with USB cable
• One 7.5V AC/DC Adapter
• Mounting Hardware with Allen Wrench
• One User Manual
3
MP12:5,80/11/4dmp.RLLEWYENOH)GNE(1MIW329ET 3
Standard Package Contents
Picture Components
Main Unit
Remote Control
AC/DC 7.5V power adaptor
UV Sensor consists of:
Sensor Unit
U-Shaped Sensor holder
Circular Ground Stand
Stake Base
Wall-Mounting Base
Thermo Hygrometer Sensor
Rain Gauge consists of:
Funnel shaped top with battery
compartment
Rain Gauge bucket
Bucket see-saw mechanism
Protective screen
4 screws for securing rain gauge to the flat surface; 4 screws for securing anemometer to vertical surface
2m (6ft) USB cable
TE923W IM1(ENG) HONEYWELL R.pmd 4/11/08, 5:24 PM4
Anemometer consists of:
Wind Cups Wind Vane
Anemometer arm
Anemometer base
PC Software
Mounting hardware
PC connection cable
4
Required for installation (not included)
- Phillips screwdriver
- Mounting pole for anemometer (optional)
- Small paper clip for reset
Installation
The Professional Weather Station TE923W-M operates at 433MHz radio frequency
wire installation is required between the main unit (receiver) and the remote weather
, so no
(transmitters).
sensors
The remote weather sensors include a thermo-hygrometer (temperature and humidity) sensor, UV (ultraviolet) sensor, anemometer (wind sensor) and a rain gauge (rain sensor). All data measured by these remote sensors is transmitted to the main unit wirelessly, with the operating range up to 328 feet (100 meters) in open area.
Remote UV sensor, anemometer and a rain gauge must be placed outdoors to measure weather
Remote thermo-hygrometers can be placed indoors or outdoors, depending on the area where the temperature and humidity are intended to be measured. If you intend measuring outdoor temperature and humidity, place the remote sensor outdoors.
Note: It is critical to assemble and power up all of the remote weather sensors BEFORE setting up the main unit.
Note: It is critical to power up and test communication between all of the weather sensors and the main unit BEFORE permanently mounting them outside.
elements.
5
MP42:5,80/11/4dmp.RLLEWYENOH)GNE(1MIW329ET 5
Before you begin
• We recommend using alkaline batteries for the remote weather sensors and the main unit when temperatures are above 32°F (0°C). We recommend using lithium batteries for the remote weather sensors when temperatures are below 32°F (0°C).
• Avoid using rechargeable batteries. (Rechargeable batteries cannot maintain correct power requirements).
ALWAYS install batteries in the remote weather sensors before the main unit.
• Insert batteries matching the polarity in the battery compartment
• Remove and discard any factory applied protective plastic film affixed to the LCD display (if any).
• During an initial setup, place the main unit close to the remote weather sensors.
• After reception is established (all of the remote readings will appear on the main unit’s display), position the remote sensors and the main unit within the effective transmission range of up to 328 feet (100 meters).
of the main unit. See placement tips in the user manual for each remote weather sensor separately.
Transmission range may be affected by trees, metal structures and electronic appliances.
• The main unit must be placed indoors.
• The effective operating range may be influenced by the surrounding building materials and how the receiver (main unit) and transmitters (weather sensors) are positioned.
• Place the remote weather sensors so that they face the main unit (receiver), minimizing obstructions such as doors, walls, and furniture.
Note: When the temperature falls below freezing, the batteries in the outdoor remote weather sensors may have reduced voltage supply and a shorter effective range. We recommend using lithium batteries at temperatures of 32
Ideally they should be placed within the line of sight
°F (0°C) and below.
IMPORTANT: Make sure that the remote weather sensors are easily accessible for cleaning and maintenance.
We recommend cleaning the remote weather sensors periodically, as the dirt and debris may affect sensors accuracy.
6
MP 42:5 ,80/11/4dmp.R LLEWYENOH )GNE(1MI W329ET 6
Ultraviolet (UV) Sensor TS704-M
FEATURES
• Ultraviolet light levels measurement
• Remote UV levels data transmission to the main unit via 433MHz signal
• 328 feet (100 meters) transmission range
• Low battery indicator
• Three different placement options – ground, stake and wall
A
B
C
G
F
D
A. LED INDICATOR
• Flashes once when the remote sensor transmits a reading to the main unit
• Flashes twice when battery power is low
B. BATTERY COMPARTMENT SCREW
Holds battery compartment door in place
C. U-SHAPED SENSOR HOLDER
Holds UV sensor in upright position
D. CURCULAR GROUND STAND
Secures sensors in the sensor holder on the flat surface
E. UV SENSOR LID
Covers UV sensor and seals battery compartment
F. BATTERY COMPARTMENT
Holds two AA-size batteries
G. BATTERY COMPARTMENT DOOR
Covers two AA-size batteries
E
7
MP 42:5 ,80/11/4dmp.R LLEWYENOH )GNE(1MI W329ET 7
Assembly
• Snap the U-shaped sensor holder onto the UV sensor unit side grooves
• Insert the round end of the U-shaped holder into one of the mounting hardware pieces provided
Battery installation
• Unscrew the lid on top of the UV sensor unit.
• Remove the screw from the battery compartment door with a small Phillips screwdriver
• Insert two 2 “AA” size 1.5V batteries (not included) matching the polarities shown in the battery compartment.
• Replace the battery compartment door and secure the screw
• Screw the UV sensor unit lid back
Mounting
There are three different options available for mounting the UV sensor: ground stand, stake and wall mount.
Ground:
Ground
• Insert the U-shaped sensor holder round end into the circular ground stand opening, matching 2 round holes in the opening
• Secure the sensor in a location with a maximum sun exposure throughout the day.
Stake:
Stake
• Snap the sharp stake end onto the metal bar and secure with the screws provided.
• Insert the other end of the metal bar into the U-shaped sensor holder and secure with the screws provided.
• Secure the sensor in a location with a maximum sun exposure throughout the day.
Wall:
• Insert the wall mounting end into the metal bar
Wal l
and secure with the screws provided.
• Snap the other end of the metal bar on to the U-shaped sens or holder and secure with the screwsprovided.
• Secure the sensor in a location with a maximum sun exposure throughout the day.
Placement tips:
The UV sensor should be mounted in the area free of sunlight shadows or reflections from the nearby objects.
8
TE923W IM1(ENG) HONEYWELL R.pmd 4/11/08, 5:24 PM8
Thermo-Hygrometer Sensor TS34C-M
FEATURES
• Remote data transmission to the main unit via 433 MHz signal
• 328 feet (100 meters) transmission range without interference
• LCD display of measured temperature and humidity
• Five (5) transmission channels selection
• Case can be wall mounted using built-in hanger
A. LED INDICATOR
• Flashes once when the remote sensor transmits a reading to the main unit.
• Flashes twice when battery power is low.
B. BATTERY COMPARTMENT
Holds two AA-size batteries
C. RESET
Resets all readings (requires small paper clip.)
D. CHANNEL SWITCH
Selects the desired channel from 1 to 5
E. WALL-MOUNT RECESSED OPENING
Keeps the remote sensor on the wall
Note: Install the batteries and select the channel before mounting the sensor.
Battery installation
• Remove the screws from the battery compartment with a small Phillips screwdriver.
• Set the channel 1 through 5. The switch is located in the battery compartment. Channel 1 is
typically selected if only one remote sensor is being used.
• Install 2 “AA” size alkaline batteries (not included) matching the polarities shown in the battery
battery compartment.
• Replace the battery compartment door and secure the screws.
• Secure the thermo-hygrometer remote sensor in the desired location.
Mounting
The remote thermo-hygrometer sensor can be placed on the flat surface or mounted on the wall
in vertical position
Use the wall mount hardware and screws provided when mounting the thermo-hygrometer
sensor on the wall
Placement tips:
The remote thermo-hygrometer sensor should be placed in the area with a free air circulation
and sheltered from the direct sunlight and an extreme weather conditions.
Ideally, place the thermo-hygrometer sensor above the natural surfaces (such as a grassy lawn).
Avoid placing the thermo-hygrometer sensor near sources of heat such as chimneys and heating
elements.
Avoid any areas collecting and radiating a heat from the sun, such as metal, brick or concrete
structures, paving, patios and decks.
• The international standard for the valid air temperature measurements is 4 feet (1.25meters)
above the ground.
9
MP 42:5 ,80/11/4dmp.R LLEWYENOH )GNE(1MI W329ET 9
Rain Gauge TS906-M
FEATURES
• Precipitation measurement
• Remote rainfall data transmission to the main unit via 433 MHz signal
• 100 feet (30 meters) transmission range without interference
• Built-in installation level
• Non-corrosive protective screen
B
A
C
A. Rain gauge bucket
Contains electronic components
B. Knob
Secures the top on the rain gauge bucket
C. Rain gauge feet
Secures the rain gauge in place
D
G
E
H
F
I
D. Funnel-shaped top with battery compartment
Contains battery compartment and rainfall counting electronics
E. Battery compartment
Holds two AA-size batteries
F. Screws
Secure battery compartment cover
G. Built-in level with bubble
Ensures level rain gauge mounting for proper operation
H. Bucket see-saw mechanism
Collects the rainfall in one of its containers and self-empties once full
I. Protective screen
Protects the rain gauge funnel from debris
10
MP 52:5 ,80/11/4dmp.R LLEWYENOH )GNE(1MI W329ET 10
Battery installation
• Unlock the funnel-shaped top on the rain gauge by turning both knobs on the sides in an anti­clockwise direction.
• Remove the funnel-shaped top lifting it off the rain gauge bucket.
• Remove 7 small screws from the battery compartment cover using a small Phillips screwdriver
• Insert 2 “AA” size alkaline batteries (not included), matching the polarities as shown in the battery compartment.
• Replace the battery compartment door and secure the screws.
• Insert the funnel-shaped top into the rain gauge bucket and secure it into place by turning the knobs clockwise.
Mounting
• Make sure that the rain gauge bucket is level – check for bubble center, inside built-in level.
• Place the protective screen over the top to protect the rain gauge from the debris.
Where practical, mount the rain gauge in place with wood screws (not included).
• Make sure that the rain gauge is in open area where precipitation falls directly into the gauge’s bucket, ideally 2-3 feet above the ground.
Placement tips
The rain gauge should be placed in an open area away from the walls, fences, trees and other
coverings which may reduce the amount of rain falling into the bucket. Additionally, trees and rooftops may be sources of pollen and debris.
To avoid the rain shadow effects, place the rain gauge horizontally, on the distance
corresponding to two to four times the height of any nearby obstruction.
It is important to locate the unit where rain can flow freely away.
11
MP 52:5 ,80/11/4dmp.R LLEWYENOH )GNE(1MI W329ET 11
Anemometer (wind sensor) TS906
FEATURES
• Wind speed and wind direction measurement
• Remote wind speed and wind direction data transmission to the main unit via 433 MHz signal
• Operating range 100 feet (30 meters)
• Wall or pole mount
A
B
A. WIND VANE
Measures wind direction
B. WIND CUPS
Measures wind speed
C. ANEMOMETER BASE
• Holds battery compartment
• Allows mounting the anemometer vertically
D. ANEMOMETER ARM
Keeps anemometer assembly together
G
D
C
E
F
E. WIND CUPS SHAFT
Holds wind cups on the anemometer arm
F. BATTERY COMPARTMENT
Holds 2 AA-size batteries
G. WALL MOUNT SCREW OPENINGS
Allows securing the anemometer in place
H. BATTERY COVER
Allows securing 2 AA size batteries on the anemometer base
TE923W IM1(ENG) HONEYWELL R.pmd 4/11/08, 5:26 PM12
H
12
Assembly
• Slide the wind cups on to the anemometer rotating shaft. Do not use force.
• Insert the Allen Wrench (provided) into the wind cup set screw opening. Tighten the set screw to secure wind cups to the rotating shaft.
• Test to ensure cups are securely fastened to the shaft.
Battery installation
Remove four (4) screws from the battery compartment with a small Phillips screwdriver.
Open the battery compartment and install 2 “AA” size alkaline batteries (not included)
matching the polarities shown.
Replace the battery compartment door and secure the screws.
Aligning
• Point the wind direction vane to the north (use a compass or map if necessary).
• Press the button inside the “SET” opening located inside battery compartment with a paper clip or similar tool. The “SET” selects a new direction for NORTH and, when pressed repeatedly, alternates between the factory default NORTH and user selected NORTH.
• Select the factory set mode. It will be also a default setting in the future.
• Set current wind direction as NORTH.
Note: Repeat this procedure every time when changing the batteries.
Mounting
Mount the anemometer onto a vertical surface, using the fittings provided.
Placement tips:
• The anemometer should be mounted in an open area with a free air flow; away from the nearby trees, buildings or other structures.
• For optimal performance, mount the anemometer at 33 feet (10meters) above the ground in unobstructed area.
13
MP 62:5 ,80/11/4dmp.R LLEWYENOH )GNE(1MI W329ET 13
Main Unit
The main unit measures pressure, indoor temperature, humidity, and receives atomic time data from the US Atomic Clock and all remote weather sensors. It should be placed indoors.
FEATURES
Time
• Precise time and date set via RF signals from US Atomic clock
• 12 or 24 hour time format
• Manual adjustment of time and date
• Calendar displaying date with month and day in 6 languages English, German, French, Italian, Spanish and Dutch
• Sunrise/set calculation for over 100 pre-programmed world cities in accordance with the geographical information entered by the user
• Moon Phase calendar and historical data for the past and future 39 days
• Dual crescendo alarms with programmable snooze
Weather
• Weather forecast for the next 12 to 24 hour in seven large icons: Sunny, Partly Cloudy, Cloudy, Light Rain, Heavy Rain, Unstable Weather and Snowy
• Barometric pressure in imperial or metric units
• Altitude adjustment for pressure compensation
• 24 hour barometric pressure history chart
• Multiple weather alerts including: Hi/Low temperature, Daily Rainfall, Hi wind gust and Hi wind speed alerts
• Indoor/Outdoor Temperature & Humidity in up to 5 remote locations (additional sensors required)
• Dew point and comfort level indicators
• Wind speed and wind gust averages and memory
• Wind direction
• Rainfall amount with minimum and maximum memory
• UV intensity with daily and weekly highs and lows
• 200 weather records without PC connection
• PC software (included) and USB port
• Operating range from 100 feet (30 meters) up to 328 feet (100 meters)
Display
• Light sensor detects low light conditions and LCD lights up automatically when adapter is connected
• Infrared remote control of all display functions
Power - Main Unit
• AC/DC adapter for automatic remote control
• 4 AA batteries
Power - Infrared Remote Control
• 2 AAA batteries
14
MP 62:5 ,80/11/4dmp.R LLEWYENOH )GNE(1MI W329ET 14
Loading...
+ 30 hidden pages