Me ME580 Owner's Manual

ME580 STEREO AMPLIFIER
OWNER’S MANUAL
ME Amplifiers Melbourne, Australia
ME Amplifiers Melbourne, Australia
Page No.
GETTING TO KNOW YOUR ME580
Safety First 1
Quick Start Connection Guide 1
INSTALLING YOUR ME580
Speaker Cabling 4
Input Leads (Interconnects) 4
Ventilation 4
Mains Power Connection 5
UNDERSTANDING YOUR ME580
General Description 6
Microcontroller Monitoring and Control 6
1. Power Up / Power Down Control 6
2. Temperature Monitoring 6
3. DC Offset Monitoring 7
4. Voltage Limiting / DC Monitoring 7
5. High Level High Frequency Output Monitoring 7
6. Output Status Indication 7
7. Amplifier Operating Status Indication 7
8. Control of Brightness of the Operating Status Light 7
9. Control of Brightness of the Standby Status Light 8
10. Remote Startup and Shutdown 8
Protection System Operation 8
1. Abnormal Conditions 8
2. Fault Detection and FAULT (Output Status) Light 9
3. Restarting the ME580 After Fault Detection 9
4. Over-Temperature Detection 9
5. Over-Temperature Shutdown 10
6. Restarting the ME580 After Over-Temperature Shutdown 10
7. Mains Fuse 10
8. Mains Fuse Replacement 10
ME Amplifiers Melbourne, Australia
ME Amplifiers Melbourne, Australia
Page No.
UNDERSTANDING YOUR ME580 (Cont’d)
High Capacitance Option 10
Bridge Mode – Higher Volume 12
Dual Amplification – Higher Quality Sound 13
GENERAL INFORMATION
Why Your ME Amplifier Is Different 14
PACKAGING AND SHIPPING 15
WARRANTY CONDITIONS 16
TROUBLESHOOTING
Faulty or Distorted Sound 18
No Sound (Both Channels) 19
Hum or Buzz Problems 20
SPECIFICATIONS 21
ME580 / ME550-II SIMILARITIES AND DIFFERENCES 22
IMPROVEMENTS OVER ME550 Series II 23
CONTACT US 24
ME Amplifiers Melbourne, Australia
ME Amplifiers Melbourne, Australia
GETTING TO KNOW YOUR ME580
SAFETY FIRST
There are no user serviceable components inside your ME580 Power Amplifier. Do not under any circumstances remove the top or bottom cover of the ME580 amplifier whilst it is connected to a power point, even if the switch at the power point is turned off.
Never allow moisture or liquids of any kind to enter the power amplifier chassis (condensation, drinks, etc.)
Use only the fuses specified by ME Amplifiers in your ME580 Power Amplifier. Fuses of a different rating may not protect your amplifier, and may create a fire hazard.
Do not switch on your power amplifier without first turning the gain control on any connected preamplifier to a minimum.
Do not disconnect any leads from the amplifier until it has been switched off and is completely discharged. (Allow 1 minute from switch off for the amplifier to discharge.)
Your ME580 Power Amplifier must only be used with a 3 pin EARTHED mains cable. Such a cable is supplied with the amplifier.
1
QUICK START CONNECTION GUIDE
If you are in a hurry to get your ME580 power amplifier operating, and it has not been installed by your ME dealer or other knowledgeable person, please follow the procedure set out below. We do recommend strongly however that you read the complete instructions in this handbook first.
1. Do not make any electrical connections unless the amplifier is disconnected from the mains power.
2. Make the connections to your program source (preamplifier, CD player with variable output, etc.) as
follows:
Use the DC Coupled inputs if you are connecting to an ME preamplifier or other DC Servo
Controlled preamplifier.
Use the AC Coupled inputs if using CD players directly, passive preamps, tube (valve) preamps,
surround sound receivers, etc. If in any doubt read “Understanding your ME580 – DC Offsets”, consult your dealer, or just use the AC inputs – as that is the safest for your speakers.
The unbalanced inputs require leads (interconnects) fitted with RCA plugs.
The balanced inputs require leads (interconnects) fitted with XLR plugs.
If using unbalanced RCA inputs be sure to set the Balanced / Unbalanced input selector switch on the
rear panel of the ME580 to Unbalanced and to Balanced when using balanced XLR inputs.
3. Connect your Speaker Cables securely to your Speaker System, ensuring that a short circuit is not
possible, even if speakers are later moved or repositioned. Shorted cables can lead to amplifier damage, and can void your warranty. CAUTION: Your ME580 Power Amplifier is designed to operate with loudspeakers with impedance in the range 4 – 8 ohms. Operation with loudspeakers of less than 4 ohms nominal impedance is not recommended.
4. Connect the Speaker Cables to the terminals on the back of the ME580 power amplifier, preferably
using high quality banana plugs. Alternatively, if banana plugs are not available, the ends of the
ME Amplifiers Melbourne, Australia
GETTING TO KNOW YOUR ME580
Speaker Cables may be bared and twisted, then inserted into the holes in the sides of the terminals before tightly screwing down the terminal covers. If using this method, make certain that all bare wire strands of the Speaker Cables are contained within the terminals, as even one stray strand of wire could cause a short circuit between a Speaker Cable and the chassis of the amplifier. Also verify that none of the Speaker Cables can make electrical contact at any point with the chassis of the ME580 or any other chassis (e.g. CD player chassis). Also ensure that a short circuit between the red (+) and black (-) terminals of either channel cannot occur. Finally, check that you have connected the speakers to the amplifier with the same polarity on both channels, i.e. ensure that the wires from the red (+) terminals on each channel of the ME580 go to the corresponding (red or +) terminals on both left and right speakers. If the speaker wires are connected the opposite way round on one speaker compared to the other, the speakers will be “out of phase” resulting in a loss of stereo image.
5. Connect the ME580 to a power point and switch the power point ON. The ME580 will then perform a
one minute initial power up self test, as detailed below. During the self test the ME580 amplifier cannot be switched on; i.e. pressing the POWER pushbutton will have no effect.
Initial Power Application Self Test
The ME logo on the front panel escutcheon will be illuminated in Mauve light, the Temperature
Light labeled TEMP will be illuminated in Amber and the Status Light labeled FAULT will illuminate Red indicating that the amplifier has mains power applied to it, and the cooling fans will come on and be ramped up in speed to a maximum over a ten second period.
At the end of the ten second period the TEMP light and the FAULT light will turn off but the fans
will continue to run at maximum speed for a further 40 seconds to allow verification of airflow from both heat sink air exhaust ports, and the ME logo will remain illuminated in Mauve light indicating that the amplifier is still in self test mode. After the 40 second airflow test time the fan speed will be ramped down to zero over a ten second period, and the ME logo will be illuminated in Amber light, indicating that the self test is complete and the amplifier is in Standby Mode.
6. Press the POWER button located in the centre of the front panel escutcheon. The illumination of the
ME logo will change from Amber to Blue, indicating that the amplifier is ON, and is operational. Music reproduction will be possible now. For the first minute or so, the sound quality may be slightly reduced until the amplifier begins to warm up; this is normal, and generally more pronounced when very cold and less noticeable if the amplifier has been used within the last 30 minutes. After several minutes, the Green TEMP light on the front panel escutcheon will come on, indicating that the amplifier is operating within the normal temperature range. When this condition is reached, the sound quality will be at its best. The time taken for normal operating temperature to be reached will depend on ambient temperature and the volume setting, as well as the load impedance of the loudspeakers being used.
Please Note: The ME580 amplifier can only be switched on ONCE per minute. This means that if the amplifier has been switched on for less than one minute and is then switched off, it cannot be switched back on until the first minute has elapsed. If the amplifier has been ON for over one minute it can be switched OFF and immediately may be switched ON. This feature is to reduce stresses caused by repeated rapid cycling between OFF and ON. If the amplifier is switched OFF before one minute has
ME Amplifiers Melbourne, Australia
2
GETTING TO KNOW YOUR ME580
elapsed since it was switched ON, the Amber illumination of the ME logo will flash on and off until one minute has elapsed. When the flashing stops, the amplifier may be switched ON.
3
ME Amplifiers Melbourne, Australia
Loading...