2.1 ACTIONS TO BE TAKEN UPON INSTALLATION
SAFE DISTANCE FIREPLACE STOVES TYPE „Zino“ FROM FLAMMABLE 5
MATERIALS, LOCATION FIREPLACE STOVES AND SMOKE EXTRACT
.................................................
.............................................
................................................................
.............................................................
................................................................
.....................................................................
.........................................................................
........................................................

• The ZINO is transported in a horizontal position.
•For facilitate transport you can use a set of solid rubber straps/belts.
that the interior lining of the stove thermal linings are remaining in their correct positions. (see Pic.11
The quality of the wood is extremely important for the optimal functioning of the stove /output, clear
glass, etc.../. The idea is to use dried hard wood with moisture content 12% to 18%. Damp wood gives
off less heat, clogs the chimney and the glass of the stove’s door. You can also use compressed wood
as a result of excessive temperature or over firing is not covered under the guarantee; two halves of
woods of the 2kg weight are equal 5-7kW.
floor of the fire chamber, laid side to side of the combustion chamber. The draught of chimney should
The use of treated wood /painted, etc. / and all types of household waste, which can disperse hazar-
dous gases, is FORBIDDEN and CANCELS OUT ANY CLAIM ON THE GUARANTEE. The use of fluid
fuel /petrol, etc. / is also forbidden.
stove and light the tinder.
will harden and that give off smoke and a smell, which
starts after the fire has burned for about 10 minutes and
ventilation in the room. The combustion
be kept closed except for fuelling to prevent entry of gases into

you want a power about 6-7kW, it is just enough to put 2kg wood in the fireplace. This is
consequence for not following this guideline. External surfaces of the stove are very hot
during operation, which has to be paid due attention to avoid an accident or burns.
2.1 ACTIONS TO BE TAKEN UPON INSTALLATION
The appliance has to be installed according to certain prescribes rules and local regulations.
The device must be built in an area with an adequate strength/capacity on the floor boards, which can
spread the weight of the stove. The stove must be positioned so as to maintain the safety distances
from any flammable materials. However, if you decide to carry out the work on your own, we advise
2.2 LIST OF STANDARDS TO BE OBSERVED DURING ASSEMBLY AND OPERATIONS
The fireplace type „ZINO“complies with STN EN 13229. For installation and operation of the fireplace
type „ZINO“should proceed in accordance with STN 92 0300 „Local fire safety appliances and heat
sources” and STN 73 4201 „The design of chimneys and flues“.

WARNING! When connecting chimney from behind so you have to remove the
cap on the chimney shell and the stopper ( see arrow Pic.5 ) and then the stopper fitted to
the top slot, which will remain free to disassembling the chimney.
2.3 SAFE DISTANCE FIREPLACE STOVES TYPE „Zino“ FROM FLAMMABLE MATERI-
ALS, LOCATION FIREPLACE STOVES AND SMOKE EXTRACTION
Appliance type series „ZINO“ must be installed in accordance with Decree MV SR No. 95/2004
statute, coll establishing specifications and requirements for fire safety during installations and
operation of heating appliances, electro thermal appliances and central heating installations
and the constructions and use of chimneys and flues. It is also necessary to respect the STN 73
4210 „Running of the chimneys and flues and connecting fuel appliances. “ The manufacturer re-
commends the installation of the fireplace appliance type series „ZINO“conducted by a Qualified
for Local Building Control and HETAS Registration. The manufacturer is only responsible for the
Caution: The Installer has to approve the fireplace before the initial operation and
issue a certificate about the safe utilisation and the correct flue gas evacuation
of 100cm. due to the radiation of heat from the front of the stove.
The fireplace type series „ZINO“must be installed so that before it left space on the layout, about
The base under appliance type series „ZINO“must be placed on a non combustible material that
will withstand heat stress. Also, all wall and ceiling materials, which the Appliance type series
„ZINO“ may be near must be non combustible materials, respect should also be used for good
„ZINO“so that it is firmly and tightly connected.
Combustion pipe can join at the top ( see Pic.4 ) or from behind ( see Pic.5 ). The average of

The combustion pipe might be of black respectively stainless steel pipes and elbows. The flue
connection must be made by the shortest route to the flue by STN 73 4210. The combustion pipe
should be implemented and consolidate in order it cannot be released accidentally or spontane-
ously. All fluing should comply with the requirements laid down in Building Regulations Section J.
which has been expertly tested. Based on expert examination of the appliance flue connection and
2.4 LOCATION THE FIREPLACE FURNACE TYPE SERIES „ZINO“ON THE
stible material( Stone Glass, Marble, Ceramic Tiles Etc). The hearth needs to project at least 30cm
are constructed of non combustible material ie Brick or stone then a minimum distance of 5cm
2.4.1 REQUIREMENTS FOR PASSING COMBUSTION AIR
The fireplace furnace type series „ZINO“can be placed directly in the heated respectively outside
the heated space. Every form of combustion uses air. The combustion of fuel uses air from the
area where is the fireplace type series „ZINO“. In case of insufficient ventilation of this area is ne-
cessary to ensure sufficient fresh air from outside the duct can be connected to the inlet throat of

ses which if touched would cause serious burning. It is therefore prohibited during the operation
of the stove to touch the appliance.
temperature in which could cause burns. It is therefore necessary drivers to use the controls
with protective gloves and the auxiliary tools that are included with the fireplace furnace type
quate supply of air for combustion of the fuel.
danger the safe operation.
The correct and safe operation of the fireplace furnace type series „ZINO“it is imperative to
observe the operating instructions and installation!!!

The customer must regularly clean ashes from an ashtray on a grid /after two full-time heating/
and check whether there is excessive fouling the ash chamber/see ( Pic.8 )
fuel/ need to check and clean the flue gas path of ash and shoot. Choose to be two deflector
After the cleaning the flue tract and insertion of parts back to its position, check the parts are
these parts. ( see Pic.11 )

The dismantling of the deflector plate 1:
-Lift plate up / approx 3cm / and remove the stainless steel beam to each slide and push to one
side and a diagonal slide it out of the fireplace.
-Pull the plate to pull himself / approx 4 cm / etc diagonal sway and slide it out of the fireplace.
The dismantling of the pass refractory plate 2:
-Push the plate upwards until it stops at the flue outlet / slide of the plate holders No.1 and No.2
see Pic.12 / clone one side and downward on a diagonal and sliding the plate in the chamber and
The installation of the pass refractory plate 2:
-Slide-plate on a diagonal into the combustion chamber and to push all the way to the top flue out-
The installation of the deflector plate 1:
-Slide plate on a diagonal to the fireplace stoves and push up and place it on the side facing the
combustion chamber, slide all the way back of the fireplace furnace.
-Stainless steel beam under a diagonal slide into fireplace oven and place it on lateral lines and
then insert the front edge of the plate / make sure that the side holders are well fitted ( see Pic.12

of the type of fireplace furnace type
Type : „ZINO......................“,
„Keep operating instructions”
“The unit can be connected to a common chimney“
“Use only recommended fuels”
The appliance is designed for: Short-term operation
Avg CO concentration at 13% O2 (%)
The average volume concentration of
The weight of the fireplace furnance

2 years` guarantee on the parts, no guarantee on glass, seals and lining the combustion chamber
The claim must be submitted to the warranty, otherwise the claim is recognized.
are unusable due to poor quality material or faulty processing.
2. The guarantee does not apply to defects resulting non-compliance with the conditions spe-
cified in the instructions for installation, operation and maintenance or that the unit is used other
than in the manner and for any purpose other than for which it is intended under normal conditi-
ons, poor or improper handling, e.g. Improper storage, improper handling, improper use of fuel.
3. The guarantee does not apply to defects caused by impurities in the fuel combustion gas
4. The guarantee also does not apply to damages caused indirectly, and damage or personal
5. The claims for non-compliance security guarantees expire, the expiry of the guarantee pe-
6. The costs associated with sending a service worker to put the fireplace furnace type series
„ZINO“not covered by the guarantee shall be borne by the customer – a user.
8. Other rights and obligations arising from liability for product defects shall be governed by
the provisions of generally binding legal regulations applicable in the Slovak Republic (Civil Code,