M&C TechGroup SP3110 Datasheet

SP3110V/RS/HEX4-135 resp. 180
Embracing Challenge
Gas Sample Probe Series SP®
Version SP3110V and SP3110 for sampling from zones with explosive gas with dierent options for calibration gas feeding, back purging and shut-o
Special Features
Approval according to ATEX for sam-
pling from Ex-zone 1 and 2
Approval according to ATEX for mount-
Dierent options for test gas feeding,
back purging and shut-o
Optimum operational reliability
Universal applicability
Adaption to nearly all process condi-
tions due to its compact and modular design
Easy mounting and maintanance
Small volume, fast response time
Application
The M&C sample probes version SP3110V and SP3110 are used for continuous extraction of explosive gases (Ex-zone 1 and 2) from dust loaden, high temperature and/or humid proc­esses. The probes can be mounted in Ex-zone 1, 2 or 21, 22. Both versions differentiate only in the sealing material of the filter housing. Version SP3110V has got a sealing out of FPM for types which are heated up to max.185°C and version SP3110 has got a sealing out of graphite for all versions heated up to more than 185 °C.
Description
The sample probes are designed for easy installation, reliable operation and trouble­free maintenance. They are versatile in appli­cation and depending on the task to be per­formed, various pre-filters series V12 or V20 with integrated volume displacer, optional with extension tubes, not included in the scale of delivery, can be simply screwed into the mounting flange of the basic probe. For error control the sample gas flow rate has to be monitored externally.
This M&C stainless steel or ceramic filter ele­ment with a large surface and high capacity is located in the external housing. The design offers little or no stagnant space outside the process. The probe housing is covered with a protection shield which is part of the Ex-approval.
The probes are designed in such a way that changing the filter element is possible with­out the use of tools. In this operation, neither the sample probe tube nor the sample line need to be removed, thus avoiding contami­nation of the clean gas path and maintaining the integrity of the system.
The special design of the optional heating of the M&C-probes version SP3110(V ) per­mits controlled heating of the complete filter housing, including the mounting flange. This ensures reliable operation external to the process preventing the temperature falling below the dew-point.
The temperature control of the M&C-probes version SP3110(V) can be done by three dif­ferent heater types.
The first possibility is a self-regulating heater version HEX4-135 or HEX4-180 (see data sheet 2-3.2) for Ex-zone 1 or 21, for gas sampling from zone 1 or 2. In dependence on the ambient temperature and the heater type, the min. temperature in the probe is 90°C resp. 120°C, the max. temperature is 120°C resp. 160°C.
The second possibility is a controlled heating version HEX1-3 for Ex-zone 1, adjustable up to 180 °C and for sampling from Ex-zone 1 or
2. The controller has to be mounted outside the Ex-zone.
The third possibility is a controlled heating version HEX1-1 for Ex-zone 1, adjustable up to 180 °C and for sampling from Ex-zone 1 or
2. The controller can be mounted inside the Ex-zone.
For calibration gas feeding or back-purging different options are possible. For example the option RS with mounted buffer vessel triggered by an explosion-proof solenoid valve is available . With the mounted option for back-purging type RS, gas can be sampled from zone 1 and 2. The back-purge pressure has to be monitored externally and has to be min. 1 bar higher than the process pressure. For the pressure control while back-purging, a corresponding special valve is mounted in the sample gas outlet. Thus an additional solenoid valve to shut off the sample gas outlet is not necessary. The back purge inlet is shut off by a check valve.
When sampling from Ex-zones, back purging is only allowed with a gas suit­able for the sampling point.
Technical specications and illustrations are without obligation, subject to modications. 10.04/11.12
M&C TechGroup Germany GmbH • Rehhecke 79 • 40885 Ratingen • Germany info@mc-techgroup.com • www.mc-techgroup.com • Fon +49 2102 935-0 • Fax +49 2102 935-111
2.11
Technical Data
Gas sample probe type SP3110V (up to 185 °C) SP3110 (more than 185 °C)
Part No. 20S5615 20S5610 Weather protection shield yes Filter housing material Stainless steel 316 / 316Ti Sealing materials Graphite, FPM Graphite Probe flange sealing material Graphite Pre-filter / sample tubes optional, see data sheet 2.14 and 2.17 Sample pressure max. 0,5-6 bar abs. Ambient temperature -20 °C to +60 °C Permissible process gas temperature depending on the temperature class, however max. 200°C at the probe entry Filter chamber volume 120 cm Filter element, porosity F-3SS150= stainless steel*, 3 micron S-2K150= ceramic**, 2 micron Sample gas outlet connection 1x 1/4“ NPTi for max. 8mm-tube connectors Connection gas outlet at option RS 6 mm Swagelok connector Mounting flange DN65 PN6, FormB, SS316Ti* >DN or ANSI possible** Weight 7 kg Marking
Option heating type HEX4 HEX4-135 HEX4-180
Part No. 20S5510 20S5520 Mounting controller in the Ex-zone 1, 2, 21 and 22 Control self-regulating Power supply 115V - 230V 50/60Hz Electrical connection cable gland, terminal range 7 - 12mm, terminals max. 4mm Marking
Case protection IP66; EN60529 Power 400W Max. temperature 120 °C 160 °C Min. temperature 90 °C 120 °C Ambient temperature -20 °C to +60 °C Low temperature alarm contact <60°C, 1 contact MC-NO, 230V 1,5A AC, 0,5ADC <100°C, 1 contact MC-NO, 230V 1,5A AC, 0,5ADC
Option heating type HEX1 HEX1-3
Part No. 20S9037 (a) Mounting controller outside the Ex-zone Control electronic Power supply 230V 50/60Hz or 115V 50/60Hz (a) Electrical connection 3 x 1,5mm Marking
Power 400W Case protection IP54; EN60529 Temperature 0 - 180 °C T3 or 0 - 135 °C T4 Ambient temperature -20 °C to +40 °C Low temperature alarm contact <120°C, 1 change-over contact, 230V 1,5AAC, 0,5ADC
Option heating type HEX1 HEX1-1
Part No. 20S9038 (a) Mounting controller inside the Ex-zone 1, 2 Control electronic Power supply 230V 50Hz or 115V 60Hz (a) Electrical connection 3 x 1,5mm Marking
Power 400W Case protection IP54; EN60529 Temperature 0 - 180 °C T3 Ambient temperature -20 °C to +40 °C Low temperature alarm contact <120°C, 1 change-over contact, 230V 1,5AAC, 0,5ADC
3
II 2G/2GD -20°C ≤ Ta ≤ +60°C EXAM BVS 04 ATEX H 045X
2
II 2 G EEx em T3..T4 / II 2 D IP66 135°C...180°C EXAM BVS 04 ATEX E 253
2
II 2 G EEx d ib IIC T3*, others on request
2
II 2 G EEx d e ib IIC T3*, others on request
* Standard, ** optional
2.11
M&C TechGroup Germany GmbH • Rehhecke 79 • 40885 Ratingen • Germany info@mc-techgroup.com • www.mc-techgroup.com • Fon +49 2102 935-0 • Fax +49 2102 935-111
Technical specications and illustrations are without obligation, subject to modications. 10.04/11.12
Technical Data
Gas sample probe type SP3110V (up to 185 °C) SP3110 (more than 185 °C)
Option back purge unit type RS RS Part No. 20S5560 (a) Power supply 230V 50/60Hz 9W or 115V 50/60Hz 9W (a) Electrical connection cable 3x1mm Marking
II 2GD EEx m II 135°C Connection G 1/2”i at the buffer vessel Max. back purge pressure 6 bar abs. Volume buffer vessel 2 liters Ambient temperature -20°C to 60°C
Option 2-way-ball valve in the probe entrance /VA
Part No. 20S9050
Operating temperature -20°C up to 185°C
Option 2/3-way-ball valve in the probe entrance /3VA
Part No. 20S9325
Backflush / Test gas connection 6mm tube
Operating temperature -20°C up to +185°C
Option pneum. drive for ball valve /VA o. /3VA MS1
Part No. 20S9055
Connection control air G1/4” i
Pressure control air 5-10 bar
Option valve for blowback or calibration gas 1/4” /R
Part No. 20S9045
Opening pressure >0,7 bar
Connection 6mm tube
Maximum blow back pressure 6 bar abs.
Maximum operating temperature +185 °C
2
Option variable calibration gas feeding /R + /CC and /CCF
Part No. 20S9045 + 20S9012
Way of test gas /R/CC = via sample gas outlet or /R/CCF = via probe filter element
Check valve /R check valve 1/4”
Opening pressure >0,7 bar
Connection 6mm tube
Maximum blow back pressure 6 bar abs.
Maximum operating temperature +185 °C
Option high performance blow back valve /BB /BBF
Part No. 20S9008 20S9006
Way of blow back gas via filter chamber via probe filter element
Check valve high performance check valve 3/8”
Opening pressure >0,7 bar
Connection 8mm tube
Maximum blow back pressure 6 bar abs.
Maximum operating temperature 185 °C
Option test gas valve / shut-off valve /C + /I
Part No. 20S9011 + 20S9009
Way of test gas via sample gas outlet with shut-off to the process
Check valve check valve 1/4”
Opening pessure >0,7 bar
Connection 6mm tube
Shut-off valve bellow-type valve with pneumatic drive
Pressure control air 3-10 bar
Connection control air 1/8” NPT i
Option second sample gas outlet /2X
Part No. 20S9015
Connection 1/4” NPT i
Option spun glass cartridge /FW
Part No. 20S9047 20S9046 Material SS316Ti, Novapress SS316Ti, Graphite
* Standard, ** Option
Technical specications and illustrations are without obligation, subject to modications. 10.04/11.12
M&C TechGroup Germany GmbH • Rehhecke 79 • 40885 Ratingen • Germany info@mc-techgroup.com • www.mc-techgroup.com • Fon +49 2102 935-0 • Fax +49 2102 935-111
2.11
Combinations of options
Option No. 1 2 3 4 5 6 7a 7b 8 9
/RS /VA /3VA /MS1 /R /R/CC(/CCF) /BB /BBF /C/I /2X
/RS X X X
/VA X X X X X X X
/3VA X X X
/MS1 X X
/R X
/R/CC(CCF) X X X
/BB X X X X
/BBF X X X
/C/I X X X X X
/2X X X X X X
X = possible combinations
X = recommended combinations
10
/FW
X
X
X
Differential pressure and T90-time
∆P and T90 at flow of: 100 200 500 1000 1500 Nl/hr
∆P with new filter element F-3SS150 0,006 0,012 0,040 0,110 0,215 bar
∆P with new filter element S-2K150 0,003 0,005 0,02 0,058 0,135 bar
T90-time for SP3110 without tube 6 3,5 1 <0,5 <0,5 s
Dimensions SP3110(V) basic version with option back purging type RS and heating type HEX4
40
RS
140
340
HEX4
270
Dimensions in mm
2.11
200
207
133
407
540
M&C TechGroup Germany GmbH • Rehhecke 79 • 40885 Ratingen • Germany info@mc-techgroup.com • www.mc-techgroup.com • Fon +49 2102 935-0 • Fax +49 2102 935-111
360 440
Technical specications and illustrations are without obligation, subject to modications. 10.04/11.12
Dimensions
Option heating HEX1-1
Dimensions in mm
Controller Scale
X1
1
L1
4
4
1
3
2
3
2
N
N
Limiter
Reset
X1.1
1
6
2
5
4
3
PA/PE
X2
1
2
190
470
210
Option heating HEX1-3
Dimensions in mm
130
X2:
EExi
X1:
EExe
Ex-area Zone 1
230
450
160
Über-
temperatur
H2
Betrieb
TA-
H1
Heizkreis
AUS EIN
Netz
AUS EIN
V1
S1
Q1 X2X1
(N2)N1
Non-hazardous area
230
Technical specications and illustrations are without obligation, subject to modications. 10.04/11.12
M&C TechGroup Germany GmbH • Rehhecke 79 • 40885 Ratingen • Germany info@mc-techgroup.com • www.mc-techgroup.com • Fon +49 2102 935-0 • Fax +49 2102 935-111
2.11
Functional diagram of the options 1 to 9
Sample probe
Sample gas out
Standard
I-air
Option /MS1
Sample probe
Sample gas out
4
2
Option /VA
Sample probe
Sample gas out
5
1
3
6
Sample probe
Sample gas out
Option /RS back purging
I-air
Option /MS1
Sample probe
Sample gas out
Option /3VA back purging/test gas
Sample probe
Sample gas out
4
7a
8
Option /R test gas/back purging
Sample probe
Sample gas out
Option /BB back purging
Sample probe
Option /C/I test gas/shut-off valve
I-air
Sample gas out
7b
9
Sample probe
Sample probe
/CC test gas
Option
Option /CCF test gas
Sample gas out
Option
/BBF back purging
Sample gas out
Sample gas out
/2 x
Option
Possible combinations of options see table page 3.
2.11
M&C TechGroup Germany GmbH • Rehhecke 79 • 40885 Ratingen • Germany info@mc-techgroup.com • www.mc-techgroup.com • Fon +49 2102 935-0 • Fax +49 2102 935-111
Technical specications and illustrations are without obligation, subject to modications. 10.04/11.12
Options pre-filter and extension tubes
Options Version Part No.
Stainless steel pre-filter with volume displacer, length 220mm, 46mm o.d., filter porosity 2µm,temperature max. 600°C, material SS316
Hastelloy pre-filter with volume displacer, length 220mm, 46mm o.d., filter porosity 2µm, temperature max. 900°C, material Hastelloy-C
Stainless steel pre-filter with volume displacer, length 520mm, 60mm o.d., filter porosity 2µm, temperature max. 600°C, material SS316
Hastelloy pre-filter with volume displacer, length 520mm, 60mm o.d., filter porosity 2µm, temperature max. 900°C, material Hastelloy-C
Hastelloy pre-filter with volume displacer, length 520mm, 60mm o.d., filter porosity 0,5µm,temperature max. 900°C, material Hastelloy-C
Stainless steel pre-filter with volume displacer, length 300mm, 31mm o.d., filter porosity 2µm, temperature max. 600°C, material SS316
Extra charge for extension of insitu stainless steel filter V20-3 or V20-4 for each 100 mm further length (from standard length
300mm to .... mm), max. 1000 mm total filter length, material: SS316.·········
Backflushable hose pre-filter with internal support tube, length: 400mm, 40mm o.D., filter porosity 15µm,temperature max. 200°C, material PTFE, SS316
Insitu ceramic filter tube in double-layer version for high blow back efficiency, with volume displacer, length 500mm, 40mm o.d., filter porosity 1µm, temperature max. 1000°C, material ceramic, SS316, connection G3/4"
Extension tube for V20.. with internal volume displacer , length 500mm, temperature max. 600°C, material SS316 Vm500 20 S 9165
Extension tube for V20.. with internal volume displacer , length 1000mm, temperature max. 600°C, material SS316 Vm1000 20 S 9170
Extension tube for V20.. with internal volume displacer , length 1500mm, temperature max. 600°C, material SS316 Vm1500 20 S 9175
For choosing the adequate pre-lter see data sheet 2-1.1.0.8 as well
V20-0 20 S 9105
V20-0/HC 20 S 9115
V20-1 20 S 9145
V20-1/HC 20 S 9155
V20-1/HC 20 S 9156
V20-3 20 S 9300
V20-3 20 S 9310
V20-T 20 S 9315
V12-1A-1 20 S 9559
Options sample tubes
Options Version Part-No.
Length 1m, material SS316Ti, temperature max. 600 °C SP2000/SS 20 S 9065
Length 1m, with volume displacer, material SS316Ti, Temperatur max. 600 °C SP2000/SS-Vm 20 S 9067
Length 1m, material Hastelloy-C, temperature max. 900 °C SP2000/HC 20 S 9090
Length 1m, material Kanthal, temperature max. 1300 °C SP2000/KA 20 S 9080
Length 1m, material Incoloy 956, temperature max. 1200 °C SP2000/IC 20 S 9072
For choosing the adequate sample tube see data sheet 2-1.1.0.6 as well
Temperature classes for sampling from zone 1 or 2
Type Possible Options* Marking Temperature class Max. process gas temp. (°C) at probe
entry
SP3110V..
SP3110V..
SP3110V.. /RS, /HEX4-135
SP3110.. /RS, /HEX..
SP3110.. /RS
* all further options mentioned on page 2 and 3 can be used additionally in all temperature classes
II 2 G / 2 GD
II 2 G / 2 GD
II 2 G / 2 GD
II 2 G / 2 GD
II 2 G / 2 GD
T6 ≤ 80 80
T5 ≤ 95 95
T4 ≤ 130 135
T3 ≤ 195 195
T2 ≤ 200 200
Max. surface temperature (°C)
Technical specications and illustrations are without obligation, subject to modications. 10.04/11.12
M&C TechGroup Germany GmbH • Rehhecke 79 • 40885 Ratingen • Germany info@mc-techgroup.com • www.mc-techgroup.com • Fon +49 2102 935-0 • Fax +49 2102 935-111
2.11