M&C TechGroup SP2600-H-C-I-BB-F Datasheet

SP2600-H/C/I/BB/F/1K190
Embracing Challenge
Gas Sample Probe Series SP®
Version SP2600-H/C/I/BB/F/1K190 and SP2600-H/C/I/BB/F/0,1GF190
Special Features
Filter element with particularly large
lter surface
Optimum operational reliability
Adaption to nearly all process condi-
tions due to its compact and modular design
Easy mounting and maintanance
Small volume, fast response time
Integrated possibility for back-ushing
and shut o the sample outlet
Easy operation and maintenance
Application
The probes M&C type SP2600-H/C/I/BB/F..., based on type SP2000-H (see data sheet
2.2.2), are used for continuous gas sampling in processes with gases of high dust content, high temperatures and/or high humidity.
Due to the particularly large filter surface and the possibility to back purge the filter ele­ment, this type of probes achieve a very long service life especially in those cases where no pre-filters can be used. For this purpose, a back purge valve and a pneumatic isolation valve for the measuring gas outlet are inte­grated inside the probe.
Version SP2600-H/C/I/BB/F/0,1GF is suitable for dusts with extremely fine particles of up to 0,1 µm grain size. Version SP2600-H/C/I/ BB/F/1K200 can be back purged very effi­ciently due to its double-ply constructed filter element with an external filter membrane of 1 µm filter porosity.
Description
The sample probes are designed for easy installation, reliable operation, trouble free maintenance and a versatile application. Depending on the application, different sample tubes (see data sheet 2-1.1.0.6), not included in the scope of delivery of the probe, are screwed into the thread (G3/4”i) of the filter housing.
The large surface filter element of ceramic or glass fiber is placed in a housing with low stagnant space outside the process.
The probes are constructed in such a way that changing the filter element does not require the sample line to be dismounted and, therefore, the contamination of the clean gas is avoided.
The special design of the heating element of the SP2600... (with protective hood) permits controlled heating of the complete filter housing including the mounting flange up to 180 °C (Version /H320 up to 320 °C).
This ensures reliable operation external to the process preventing the temperature falling below the dew-point.
The temperature of the standard probe is controlled by an integrated compact design capillary sensor thermostat with an excess temperature limit switch and an alarm func­tion for temperature failure in compact arrangement directly to the probe.
Feeding the test gas is possible via an inte­grated check valve.
Additional functions of the probe SP2600­H/C/I/BB/F...:
Calibration gas will be injected into the probe through a check valve /C directly to the sample outlet. No calibration gas is lost into the stack.
An isolation valve /I shuts off the sam­ple outlet from the internal filter area.
Through a high flow rate check valve / BB/F, which is fixed to the filter housing wall, blow back of the incorporated ceramic filter element will be done incl. the filter area and the insitu probe tube or the pre-filter.
Technical specications and illustrations are without obligation, subject to modications. 03.03/02.08
M&C TechGroup Germany GmbH • Rehhecke 79 • 40885 Ratingen • Germany info@mc-techgroup.com • www.mc-techgroup.com • Fon +49 2102 935-0 • Fax +49 2102 935-111
2.5
Technical Data
Gas Sample Probe Version SP2600-H/C/I/BB/F/0,1GF190 SP2600-H/C/I/BB/F/1K190
Part No. 20S3550 20S3540
Integrated backflush via filter element
Protective cover yes
Terminal box IP54 EN60529
Filter housing material Stainless steeel 316 / 316Ti*
Sealing materials FPM*
Probe flange sealing material Novapress
Insitu probe tube/prefilter Optional
Sample pressure max. 0,4-6 bar* abs.
Ambient temperature -20 °C to +60 °C*** /PT100, /Fe-CuNi, /Ni-CrNi** = -20°C to +80°C
Filter chamber volume 280 cm
Filter element, porosity 0,1 µm 1µm
Thermostat, Temperature adjustment 0-180°C* /PT100** /Fe-CuNi** /Ni-CrNi**
Ready for operation after 40min
Low temperature alarm contact Change-over contact Contact rating: 250V, 3A~, 0,25A= Alarm point: ∆T 30°C
Sample gas outlet connection 1x 1/4“ NPTi* tube connectors ø 6, 8 or 10 mm**
Backflush/Test gas connection backflush: tube Ø 8mm, span: tube Ø 6mm
Shut off valve connection /I 1/8” NPT i
Pressure range contol air /I 3 - 10 bar
Power supply 230V 50/60 Hz, 800W /115V** = 115V 60Hz, 800W (fuse protection 10A)
Electrical connections Terminals max. 4mm2, 2x PG 13,5 cable gland
Electrical equipment standard EN 61010, EN 60519-1
Mounting flange DN65 PN6-B, SS316Ti* >DN or ANSI possible**
Weight 19kg*
* Standard ** Options *** In case of higher ambient temperatures use option PT100 (Part No. 20S9025) or thermocouple Fe-CuNi respectively Ni-CrNi (Part No. 20S9027 resp. 20S9028) instead of the thermo-
state controller. Then, an additional electronic temperature controller (see data sheet 2-5.1) is necessary.
3
Differential pressure and T90-time
∆P and T90 at flow of: 100 200 500 1000 1500 Nl/hr
∆P with new filter element S-1K190/0,1GF190 0,007 0,011 0,02 0,035 0,040 bar
T90-time for SP2600-H.. without tube 8 5,5 3 1 <0,5 s
Versions and options (extract)
Options (Extract) Data sheet Version Part No.
Execution with power supply 115V/60Hz /115V 20 S 9030
Execution with second outlet for sample gas 1/4" NPTi* /2x* 20 S 9015
Execution with with PT00 sensor instead of the thermostat, without temp. controller /PT100 20 S 9025
Execution with thermoelement FE-CuNi ( type J ) instead of thermostat, without temp. controller /Fe-CuN 20 S 9027
Execution with thermoelement Ni-CrNi (type K) instead of thermostat, without temp. controller /Ni-CrNi 20 S 9028
Execution with second PT100 sensor /2-PT100 20 S 9026
Execution with special adapter flange size DN..PN6 or ANSI..150 lbs /DN 20 S 9004
Execution with gas pre-heater GVW1, material SS304 2-1.2.5 /GVW1 20 S 9058
Execution with connection of the gas pre-heater to valve ”BB” and to gas inlet 2-1.2.5 /GVW 20 S 9062
Execution with steam heating, without controller and valves /D 20 S 9033
2.5
M&C TechGroup Germany GmbH • Rehhecke 79 • 40885 Ratingen • Germany info@mc-techgroup.com • www.mc-techgroup.com • Fon +49 2102 935-0 • Fax +49 2102 935-111