SP210-H
Embracing Challenge
Gas Sample Probe Series SP®
Electrically heated, compact version SP210-H / SP210-H/W
Special Features
Sampling of dust loaded process gases
Small volume, fast response time
Easy mounting and maintenance
Self-regulated electrical heater
Alarm contact for low temperature
Outdoor mounting with protective cover
Insitu probe tube optional
Application
The M&C gas sample probes version SP210-H
and SP210-H/W are applicable for continuous
gas sampling.The compact design requires
only limited space.
The gas sample probe SP210-H/W is
equipped with an extra protective cover
preferably for outdoor mounting.
Description
The design of the M&C probes version
SP210-H and SP210-H/W guarantees simple
mounting, safe operation and problem-free
maintenance.
Changing the external filter element needs
no tools and no disassembling of the sample
line. The complete filter assembly is removed
out of the probe head. This simplifies the
checkup of the filter element and the gaskets.
The filter area of the probe head respectively the insitu probe tube can be cleaned
very easely without dismounting the sample
probe. The large external filter element of
ceramic with 2µm porosity is heated up with
the stainless steel probe head to constant
180 °C, using a special selfregulated heating
element. This avaoids dew point problems at
the probe flange and filter area. A heat insulation covers all sides of the probe and ensures
an optimized heat distribution as well as safe
operation.
The power supply of the probe can be in
a range between 110V and 240V without
switching. No thermostat or temperature limiter are necessary.
The separate thermo switch enables a low
tem-perature monitoring (<160 °C, NO). For
electrical connection a junction box with
terminals is mounted.
The gas sample probe SP210-H/W equipped
with a protective cover with quick clamps is
recommended for outdoor-mounting.
The stainless steel insitu probe tube SP210/
SS (option) is screwed into the DN65 PN6
mounting flange.
The maximum operating temperature of the
tube out of stainless steel is 600 °C.
In case to avoid cooling and condensation of
the sample in the insitu tube from the sample
point to the heated sample probe the SP
30-H or SP 35-H heated sampling tubes can
be used.
Technical specications and illustrations are without
obligation, subject to modications. 10.04/06.06
M&C TechGroup Germany GmbH • Rehhecke 79 • 40885 Ratingen • Germany
info@mc-techgroup.com • www.mc-techgroup.com • Fon +49 2102 935-0 • Fax +49 2102 935-111
2.7
Technical Data
Probe series SP® compact version SP210-H compact version SP210-H/W
Part No. 02S1000 02S1010
Protective cover YES
Degree of protection IP54 EN60529 IP55 EN60529
Insitu probe tube SS210/SS optional*, operating temperature max. 600 °C
Flow max. 500Nl/h at 600 °C
Sample pressure 0,4 to 2 bar abs.
Ambient temperature -20 °C to +60 °C
Dust load max.1 g/m
Filter chamber volume 100 ml
Filter element type S-2K, filter fineness 2 µm, ceramic
Probe heating +180 °C self-regulated
Ready for operation after 2 hours
Low temperature alarm contact, alarm point <160 °C, NO
Low temperature alarm contact, contact rating 250V-3A AC, 30V-3A DC
Connection sample outlet 1/4"-NPT inside with Swagelok tube connector ø6 x 1 mm
Power supply 110 up to 240V 50/60Hz
Power consumption start up: 400VA, usual: 100VA, (fuse 6A)
Electrical connection terminals max. 2,5 mm2, 2x PG11 cable glands
Electrical equipment standard EN 61010, EN 60335-1
Mounting flange DN65 PN6, B stainless steel 316Ti
Material of sample contacting parts stainless steel 316 / 316Ti, FPM, ceramic
Dimensions 170x220x230 mm, w x h x d 170x220x235 mm, w x h x d
Weight 6,5 kg 8,5 kg
Options
02 S 9200 Insitu probe tube out of stainless steel 316Ti type SP210/SS, connection G3/4“ o, ø 10/12, length
1 m*, incl. flange gasket.
10S9005 Calibration flange, DN65PN6 with 1/8“NPT connection inclusive flange gasket and screw set
M12x80.
* Standard, other versions on request.
3
∆P and T90 at flow of: 100 200 500 Nl/hr
∆P pressure loss with new filter element S-2K 4 7 15 mbar
T90 time with insitu probe tube SP210/SS 4,0 2,5 <1,0 sec.
Dimensionen
235
220
170
ø 160
2xPG11
Wiring
1000 230
Option: 02S9200
ø 12
100W
100W
TA-
PE
521
43
6
Dimensions in mm
2.7
Power
110-240V,50/60Hz
Temp.Min.Alarm (NO)
M&C TechGroup Germany GmbH • Rehhecke 79 • 40885 Ratingen • Germany
info@mc-techgroup.com • www.mc-techgroup.com • Fon +49 2102 935-0 • Fax +49 2102 935-111
Sample out
Technical specications and illustrations are without
obligation, subject to modications. 10.04/06.06