M&C TechGroup SP2100-H Datasheet

SP2100-H
Embracing Challenge
Gas Sample Probe Series SP®
Electrically heated, compact version SP2100-H
Special Features
Sampling of dust loaded process gases
Small volume, fast response time
Self-regulated electrical heater
Insitu probe tube 1 m long
Easy mounting and maintenance
Application
The patented M&C gas sample probe ver­sion SP2100-H is used for continuous gas sampling.
The compact design requires only limited space. It is to be mounted in a weather-proof position.
Description
The design of the M&C probe version SP2100-H guarantees simple mounting, safe operation and problem-free maintenance.
Changing the external filter element needs no tools and no disassembling of the sample line. The complete filter assembly is removed out of the probe head. This simplifies the checkup of the filter element and the gaskets. The filter area of the probe head respec­tively the insitu probe tube can be cleaned very easely without dismounting the sample probe.
The large external filter element of ceramic with 2 µm porosity is heated up with the stainless steel probe head to constant 180°C, using a special self-regulated heating ele­ment. This avoids dew point problems at the probe flange and filter area.
A heat insulation covers all sides of the probe and ensures an optimized heat distribution as well as safe operation.
The power supply of the probe can be in a range between 110V and 240V without switching.
No thermostat or temperature limiter is nec­essary. The separate thermo switch enables a low temperature monitoring (<160°C, NO). For electrical connection a junction box with terminals is mounted.
A one-meter stainless steel sampling tube is provided. This is screwed into the mounting flange. The maximum operating temperature of the tube out of stainless steel is 600°C.
In case to avoid cooling and condensation of the sample in the insitu tube from the sample point to the heated sample probe the SP 30-H or SP 35-H heated sampling tubes can be used.
The wide range of M&C probe accessories offers various insitu probe tubes and pre-fil­ters to solve your specific sampling problem.
Technical specications and illustrations are without obligation, subject to modications. 10.04/06.06
M&C TechGroup Germany GmbH • Rehhecke 79 • 40885 Ratingen • Germany info@mc-techgroup.com • www.mc-techgroup.com • Fon +49 2102 935-0 • Fax +49 2102 935-111
2.8
Technical Data
140
ø 160
1000
280
ø 25
sample out
sample out
Probe series SP
Part No. 10S1000
Sample tube Type SS, stainless steel 316Ti, length 1 m*
®
compact version SP 2100-H
10S1100
no
Sample temperature max. 600 °C*
Sample pressure 0.4 to 2 bar abs.
Ambient temperature -20 °C to +60 °C
Recommended for dust loadings up to 2 g/m3*
Filter chamber volume 120 ml
Filter element S-2K 150, filter porosity 2 µm, ceramic
Probe heating temperature +180 °C self-regulating
Ready for operation after 2 hours
Temperature alarm contact, alarm point <160 °C, NO
Temperature alarm, contact rating 250V-3A AC, 30V-3A DC
Connection sample outlet 1/4"-NPT inside, for max. 10 mm tube connectors
Power supply 110 up to 240V 50 / 60Hz
Power consumption start up: 400VA, usual: 100VA, (fuse 6A)
Electrical connection terminals max. 2,5 mm2, 2x PG11 cable gland
Electrical equipment standard EN 61010, EN 60335-1
Degree of protection IP54, EN 60529
Mounting flange DN65 PN6,B stainless steel 316Ti
Material of sample contacting parts SS 316 / 316Ti, FPM, ceramic
Weight 9 kg
Options
10S9005 Calibration flange, DN65PN6 with 1/8“NPT connection inclusive flange gasket and screw set
M12x80.
* Standard, other versions on request.
∆P and T90 at flow of: 100 200 500 1000 Nl/hr
∆P pressure loss with new filter element S-2K150 7 11 20 35 mbar
T90 time – without sample tube/prefilter – 6,0 3,5 1,0 < 0,5 sec
Dimensions
Dimensions in mm
2.8
M&C TechGroup Germany GmbH • Rehhecke 79 • 40885 Ratingen • Germany info@mc-techgroup.com • www.mc-techgroup.com • Fon +49 2102 935-0 • Fax +49 2102 935-111
Technical specications and illustrations are without obligation, subject to modications. 10.04/06.06
Loading...