M&C TechGroup SP2006-H280-DIL Datasheet

Page 1
SP2006-H/DIL...
Embracing Challenge
Gas Sample Probe Series SP®
Versions SP2006-H/DIL... and SP2006-H280/DIL Gas Sample Dilution Probe
Special Features
Based on probe SP2000-H/....
Electrically heated up to 180 °C or 280 °C
NEMA 4, FRP housing
tional safety lter
Including a dilution gas pre-heater
No dew point problems
Dilution ratios from 10:1 up to 500:1
With check gas connection
Independent of the process temperature
Changing of dilution and bypass block
without any tools within a few minutes
No disconnection of any tubes or hoses
for changing of dilution or bypass block
Easy operation and maintenance
Application
The electrically heated M&C dilution probe is applicable for such processes, where the measuring procedure or the handling of the process gas require the dilution of the sample respectively the component to be measured.
Typical applications are the use with toxic gases, the moisture measurement and the emission measurement in flue gases.
The M&C dilution probe SP2006-H/DIL... is based on the well tested M&C gas sample probe SP2000-H. This enables the user to adapt the probe to nearly every application, using for example special filter techniques or special materials.
Description
The dilution unit including the critical orifice is mounted directly at the probe body and therefore heated up with the probe to a sta­ble temperature. The incorporated pre-heater heats up the dilution gas to the probe tem­perature. Both steps avoid that sample gas decreases under the dewpoint. Calibration gas enters the probe via an integrated con­nection. The probe can be heated up to 180 °C or 280 °C. As an option a heated manual operated 2 way ball valve is available. It is inte­grated in the sample gas inlet and shuts off the probe head from the process, for exam­ple during the change of the filter element. Additional the option ‘blow back in front of ball valve’ via the probe flange is available.
Through an optional high flow rate check valve /BB, which is fixed to the internal probe area, blow back of the filter housing area and the insitu probe tube will be done.Through the optional high flow rate check valve /BB/F, which is fixed to the filter housing wall, blow back of the incorporated ceramic filter will be done incl. the filter area and the insitu probe tube. The optional isolation valve /I shuts off the sample outlet from the internal filter area.
To optimize the blow back, an incorporated accumulator tank with a volume of two lit­ers is available as option. To drive this tank an optional air actuated or solenoid valve is offered.
The necessary dilution gas pressure can be adjusted by the precision pressure controller with pressure gauge.
A vacuum pressure gauge indicates the func­tion of the dilution system.
The pressure controller and pressure gauges, necessary for the dilution function, have to be ordered separately. The external control unit -S is equipped with an additional shut­off ball valve and a flowmeter to adjust the test gas quantity. The set -S1 includes an additional pressure controller for the option bypass injector -B or -BR.
The dilution probe realises dilution rates in a range of 10:1 to 500:1. A high dilution rate causes a low sample flow from the process. With underpressure conditions the response time can be minimised using the optional heated bypass injector -B which is integrated directly upstream the dilution unit. It is avail­able with recirculation into the process -BR as well.
The construction of the probe guarantees an operation which is independent from the process temperature and is easy to maintain as well.
Technical specications and illustrations are without obligation, subject to modications. 04.06/04.08
M&C TechGroup Germany GmbH • Rehhecke 79 • 40885 Ratingen • Germany info@mc-techgroup.com • www.mc-techgroup.com • Fon +49 2102 935-0 • Fax +49 2102 935-111
5.2
Page 2
Gas sample dilution probe version SP2006-H/DIL/BR/BB or /BBF
Bypass gas
2x outlet not diluted
Double Pre-heater
Probe heater
Sample out
diluted
Vacuum
Dilution gas
Double Pre-heater
Probe heater
Bypass gas
Dilution gas
Blow back
Cal. gas
Sample out diluted
Dilution block
Bypass block
Bypass return
Ground plate Filter
Blow back
Cal. gas
37
Option:
Option
Sample back to process
Sample out not diluted
Sample out diluted
180°C
Blow back
Option:BB
Cal. gas
Option:BB-F Blow back
Bypass
Vacuum gauge
Dilution gas
Temp. sensor
Option -S / -S1 external control panel
-S1
132 (3HE)
Bypass-Injector
3,0
4,0
2,0
5,0
1,0
6,0
0,0
2,0
1,0
Gas connections dilution gas, test gas, pressure control, bypass gas: ø 6 mm or on request 1/4“ (a) sample gas out: ø 8 or 12 mm or on request ø 5/16“ or 1/2“ (a)
Dimensions in mm
Dilution gas
3,0
4,0
0,0
19" (84TE)
5,0
6,0
-S
Test gas Injector-Underpressure
Open
Open
-0,8
-0,6
-0,4
-1,0
-0,2
0,0
-S1
-S
-S
Test gas Dilution gas / Bypass gas
FI
15-150Nl/h
Bypass gas
0-6 bar
PI
SP2000H/DIL...
Dilution gas
0-6 bar
PI PI
Underpressure measuring point
-1..0 bar
5.2
M&C TechGroup Germany GmbH • Rehhecke 79 • 40885 Ratingen • Germany info@mc-techgroup.com • www.mc-techgroup.com • Fon +49 2102 935-0 • Fax +49 2102 935-111
Technical specications and illustrations are without obligation, subject to modications. 04.06/04.08
Page 3
not diluted
Sample out
Sample out diluted
180°C
Cal. gas
Vacuum gauge
Dilution gas
not diluted
Sample out
Sample out diluted
280°C
Cal. gas
Vacuum gauge
Dilution gas
not diluted
Sample out
Sample back to process
Sample out diluted
180°C
Cal. gas
gauge
Dilution gas
Bypass -BR
Vacuum
Sample back to process
Sample out not diluted
Sample out diluted
180°C
Blow back
Option:BB
Cal. gas
Option:BB-F Blow back
Bypass -BR
Vacuum gauge
Dilution gas
Bypass -BR
not diluted
Sample out
Sample gas back to process
Cal. gas
180°C
diluted
Sample out
Dilution gas
Vacuum gauge
/VA
Function Diagrams
Sample out not diluted
Sample out diluted
180°C
Cal. gas
Bypass -B
Vacuum gauge
Dilution gas
Bypass out
SP2006-H/DIL
SP2006-H/DIL-B
SP2006-H280/DIL
SP2006-H/DIL-BR
SP2006-H/DIL-BR-VA
Technical Data
Series SP
Insitu sample tubes and pre filters optional on request see leaflet 2-1.1a; 2-1.5.1; 2-1.6.1; 2-1.9.5
Dilution rates with the critical orifices ”a“ - ”g“
Sample flow rate depending on the critical orifices ”a“ - ”g“ a = 1,4 b = 2,7 c = 5,5 d = 11 e = 19* f = 28 g = 55 l/hr
Possibility to adapt the dillution factor with dillution gas pressure-adjustment -5% to +30%
Dillution gas flow rate with injector version I or II I: 480 - 600Nl/hr, optional for higher dilution rates II: 1800-3000 Nl/hr
Dilution gas pressure on inlet of pressure controller min. 4,5 bar g, max. 16 bar g
Bypass injector /B: gas pressure - gas flow rate - sample gas flow rate at approx. 2 bar g - injector gas approx. 300 l/hr - sample gas approx. 150 l/hr
Process pressure 0,9 up to 2 bar abs.
Fault caused by process temperature variations operation independent from process temperature
Fault caused by process under- or overpressure no fault as long as the differential pressure ∆P at the dilution unit is
Fault caused by atmospheric pressure variations <1% with a variation of 50 mbar
Materials in contact with the sample gas stainless steel 316Ti, quartz glass, FPM, graphite
Weight approx. 30 kg
*Standard, others to be indicated along with order, intermediate values possible.
1)
approx. at 3 bar dilution gas behind pressure controller.
2)
-5% not possible for orice „g“.
3)
with injector version I. Further technical data see leaet SP2000, 2-1.1a.
Technical specications and illustrations are without obligation, subject to modications. 04.06/04.08
®
3)
SP2006-H/DIL-BR-BBF (-BB)
Version gas sample dilution probe SP2006-H/DIL ...
a = 500 b = 200 c = 100 d = 50 e = 30* f = 20 g = 10 : 1
2)
>0,5 bar g and test gas is given to the probe under process conditions
M&C TechGroup Germany GmbH • Rehhecke 79 • 40885 Ratingen • Germany info@mc-techgroup.com • www.mc-techgroup.com • Fon +49 2102 935-0 • Fax +49 2102 935-111
1)
5.2
Page 4
Part No. Type M&C gas sample dilution probe SP2006-H/DIL .... with orfice ”e“ for dillution ratio 30 : 1 standard
SP2006-H/DIL dilution probe 180 °C without ball valve upstream of the filter element
SP2006-H280/DIL dilution probe 280 °C without ball valve upstream of the filter element
SP2006-H/DIL-VA dilution probe 180 °C with heated manual operated ball valve upstream of the filter element
SP2006-H/DIL-B dilution probe 180 °C with bypass injector and bypass gas to the vent
SP2006-H/DIL-BR dilution probe 180 °C with bypass injector and bypass gas recirculation
SP2006-H/DIL-BBF dilution probe 180 °C with blow back via the filter element
SP2006-H/DIL-BB dilution probe 180 °C with blow back via the filter chamber
SP2006-H/DIL-I dilution probe 180 °C with pneumatic isolation valve to shut off the sample outlet from the filter chamber
SP2006-H/DIL-BR-I dilution probe 180 °C with bypass injector, bypass gas recirculation and isolation valve to shut off the sample out-
let from the filter chamber
SP2006-H/DIL-BR-BB dilution probe 180 °C with bypass injector, bypass gas recirculation and blow back via the filter chamber
SP2006-H/DIL-BR-BBF dilution probe 180 °C with bypass injector, bypass gas recirculation and blow back via the filter element
SP2006-H/DIL-BR-VA dilution probe 180 °C with bypass injector, bypass gas recirculation and heated manual operated ball valve up-
stream of the filter element
20S4402 (a) SP2006-H/DIL-2x dilution probe 180 °C with second sample outlet
20S4423 (a) SP2006-H/DIL-B-2x dilution probe 180 °C with bypass injector, bypass gas to the vent and second sample outlet
20S4424 (a) SP2006-H/DIL-BR-2x dilution probe 180 °C with bypass injector, bypass gas recirculation and second sample outlet
20S4250 SP2000H/DIL-S option: control panel with 1 pressure controller, 2 gauges, flowmeter, 2 ball valves
20S4260 SP2000H/DIL-S1 option: control panel with 2 pressure controllers, 3 gauges, flowmeter, 2 ball valves
Part no. 20 S 4300 : compl. set critical orice a-g , injector orice II , orice seals control panel -S, -S1 incl. wall mounting housing optional available: -S-G, -S1-G.
Other versions on request.
5.2
M&C TechGroup Germany GmbH • Rehhecke 79 • 40885 Ratingen • Germany info@mc-techgroup.com • www.mc-techgroup.com • Fon +49 2102 935-0 • Fax +49 2102 935-111
Technical specications and illustrations are without obligation, subject to modications. 04.06/04.08
Loading...