PSP4000- H
Embracing Challenge
Portable Gas Sample Probe
PSP4000-H /C /T
Special Features
Light, easy to handle and compact 
 
construction
 Electrically heated – adjustable from 100 
 
to 180 °C 
With integrated micro-lter
 
Variable probe tube- and connection 
 
technique
Integrated temperature measurement
 
Sample extraction also with heated 
 
sample probe tube
Application
Previously, gas sample probes designed for 
stationary use had to be used for inspection 
measurements carried out at different locations. The weight and  bulkiness of such 
units often caused problems for technicians 
engaged in mobile measurements.
Now the light, handy and heated gas-sample 
probe PSP4000-H has been developed as 
a logical complement to the portable M&C 
sample gas conditionig systems. Despite its 
compact design, the unit guarantees a full 
range of functions. To avoid cooling and 
condensation of sample gas in the extraction area, a heated sample probe tube  
SP34-H.. (see data sheet 2-2.2) is available.
Description
The portable gas sample probe PSP4000-H... 
is electrically heated. Temperature controlling 
is achieved by an integrated capillary sensorthermostat, adjustable from 100 to 180 °C. A 
signal lamp is extinguished on reaching the 
operating  temperature and flashes in the 
cycle of temperature regulation. A carrying 
handle and a chain for in situ attachment 
are mounted on the heat-isolated housing.  
The integrated micro-filter element with 
a fineness degree of 2 µm reliably retains 
solid impurities and can be changed easily. For heavy-oil firing measurements,  
a stainless-steel filter cartridge /FW for filterpads is optionally available.
The wide and versatile range of sampling 
probes with diameters from 6 to 12 mm ø, 
adapters and thread fittings allows adaptation 
to the most varied circumstances.
At the version PSP4000-H/C calibration gas 
injection into the probe is possible  without 
dismounting the probe.
Simultaniously temperature measurement 
during sample extraction is also available for 
version PSP4000-H/C/T.
In conjunction with the gas sample 
probe PSP4000-H..., a specially designed  
heated sample line PSP4M4/6 with inter-
changeable PTFE hosing or PSP-W4M4/6 
with a smaller outside diameter is supplied. 
The probe’s electrical power is then fed 
to the probe via the feed line integrated 
within the sample line. An aluminiumcomposite case is optionally available  
for the safe transport of the probe and up to 5 
meters of type PSP4M4/6 respectively 8 m of 
type PSP-W4M4/6 heated sample line.
Technical specications and illustrations are without 
obligation, subject to modications. 09.96/06.06
M&C TechGroup Germany GmbH • Rehhecke 79 • 40885 Ratingen • Germany 
info@mc-techgroup.com • www.mc-techgroup.com • Fon +49 2102 935-0 • Fax +49 2102 935-111
2.18

Portable Gas Sample Probe PSP4000-H...
Sample facilities
Sample tubes incl. 
connector 
Length:
 1 m *
Material:
Tube 6x1mm
SS316
3/8"
40S9020
Basic version PSP4000-H
40S1000
Tube 8x1mm
Tube 10x1mm
Tube 12x1mm
Option:
1/4"-sleeve 
at end of tube
40S9030
40S9040
40S9050
3/8"
R 2"-thread 
adapter
40S9070
Flange
DN65 PN6 *
3/4"
Adapter 
3/4"-8mm
3/4"
3/8"
8
40S9060 40S9005
Connector incl. 
PTFE-ferrule 
8mm
3/8"
Connection
Ø6*
40S1005
Heated sample line
Option:
PSP 4M4/6
01B4034(W)/36(W)/37(W)
PSP4000-H/C
100-180°C
Calibration gas 
connection
Cable 4m * 
with plug
Ø6
Adapter for extensible probe length 
Tube 8x1mm , Material: SS316
Extensible probe tube length 
of 80-200mm
* standard
40S9080
Adapter with 
cone-shaped part 
for openings 
of Ø10-20mm
40S9000
Thermo 
couple 
sensor
PSP4000-H/C/T
40S1015
Swagelok union 
94S0025
Plug
94S0020
O-Ring 
94S0030
Thermo couple 
sensor
PTFE-key ring 
94S0035
2.18
M&C TechGroup Germany GmbH • Rehhecke 79 • 40885 Ratingen • Germany 
info@mc-techgroup.com • www.mc-techgroup.com • Fon +49 2102 935-0 • Fax +49 2102 935-111
Technical specications and illustrations are without 
obligation, subject to modications. 09.96/06.06

Technical Data
Probe Series SP® Portable Version PSP4000 PSP4000-H  PSP4000-H /C  PSP4000-H /C /T
Part No. 230V 
Part No. 115V 
Sample temperature max. 600 °C *standard
Sample pressure max. 1 bar
Ambient temperature -20°C to +60°C
Filtration chamber volume 40 cm
Filter element S-2K ceramic, 2 µm
Probe temperature adjustable between 100 to 180°C, pre-set at works to 180°C
Ready for operation After approximately 30 minutes
Gas inlet Basic connection G 3/8"i, probe tube or adapters optional
Gas outlet 1/8" NPT + tube connector 6 mm (8 mm optional)
Electrical power supply 220-240V 50/60Hz, 200 W or 115V 60Hz
Electrical connection Plug and socket connector 7 pin with 4 meter connection cable
Electrical equipment standard EN 61010, EN 60335-1
System of protection IP40 EN 60529
Material Stainless steel 316Ti, ceramic, FPM
Weight 3,5 kg
Calibration gas connection for SS-tube/Plastic hose ø 6 mm no yes yes
Temperature measurement with Thermocouple sensor FeCuNi, 
length 600 mm with 4 m connection cable and standard plug. 
40S1000 
40S1000a
3
and pipe clamp for attachment of heated sample line
no no yes
40S1005 
40S1005a
40S1015 
40S1015a
Dimensions
 300 
 420 
PSP4000-H
Dimensions in mm
Technical specications and illustrations are without 
obligation, subject to modications. 09.96/06.06
Aluminium
M&C TechGroup Germany GmbH • Rehhecke 79 • 40885 Ratingen • Germany 
info@mc-techgroup.com • www.mc-techgroup.com • Fon +49 2102 935-0 • Fax +49 2102 935-111
2.18

Options
Part.-No.
40S9130 extra price for PSP4000-H.. with sample outlet ø 8 mm tube connector
40S9100 extra price for PSP4000-H /FW with special filter cartridge filled with special spun glass with M12-connection, material SS316Ti, FPM
sample adapter with variable probe tube length:
40S9005 3/8" adapter fitting with gasket and 8 mm PTFE sealing ring
40S9000 adapter with cone-shaped part for openings of ø 10-20 mm and ø 8 mm probe tube out of stainless steel 316, extensible 
80-200 mm.
40S9010 ø 8 mm probe tube out of stainless steel 316Ti with position indication, for extensible probe length of 190-300 mm.
fixed probe tubes with male connector G 3/8", length 1 m:
40S9020 Material: stainless steel SS316Ti, ø 6 mm, max. 600 °C
40S9030 Material: stainless steel SS316Ti, ø 8 mm, max. 600 °C
40S9040 Material: stainless steel SS316Ti, ø 10 mm, max. 600 °C
40S9050 Material: stainless steel SS316Ti, ø 12 mm, max. 600 °C
40S9108 Material: Titane, ø 6mm, max. 400 °C
40S9109 Material: Hastelloy® C, ø 6/8 mm, max. 900 °C
40S9112 Material: Inconell® 625, ø 12 mm, max. 1200 °C
40S9106 Material: Kanthal®, ø 15 mm, max. 1300 °C
40S9113 Material: Silicon nitride-ceramic, shock-proof, ø 6,5/12,5 mm, max. 1400 °C
40S9110 Material: Ceramic-Aluminium-Oxyd 1), ø 12 mm, max. 1800 °C, for mounting tube adapter PSP4000H/AO Art. Nr. 40S9111 is necessary 
40S9111 Tube adapter PSP4000H/AO, material: stainless steel SS316Ti
heated sample probe tubes SP34-H...:
40S9115 heated sample probe tube SP34-H with incorporated thermostate
40S9120 heated sample probe tube SP34-H1.1 with thermocouple sensor FeCuNi
40S9125 heated sample probe tube SP34-H2 with PT100 sensor
pre-filter SP1
04S5000 sintered metal pre-filter SP1, 3µm, material SS316/SS316Ti, connection 1/4" NPT o.
04S5010 sintered metal pre-filter SP1, 20µm, material SS316/SS316Ti, connection 1/4" NPT o.
40S9054 connection fitting for sample probe tube 12mm for mounting of a SP1. material: SS316, max. 600°C
equipment, out of stainless steel SS316Ti for placing the probe stationary:
40S9060 intermediate connection adapter G3/4"o - G3/8"i / 8 ø with gasket 3/8".
40S9070 connection mounting nipple of R 2"o. DIN 2999/1 with G 3/4"i und G 3/8"i
40S9080 mounting flange DN65 PN6 B with thread connection 3/4"i ISO and gasket
90S2075 flange gasket set for DN65 PN6 B consisting of Klingerit gasket and screws M12
heated sample line PSP4M4/6 spec. made for probe PSP4000H:
01B4034  beginning connection part I with pipe end, for interchangeable tube 4/6, incl. PT100 and 1,5 m extension cable axial at the back, with 7 pins 
plug
01B4037 end connection part K with spec. pipe end, for interchangeable tube 4/6, 0,5 m extension cable axial at the back, with 7 pins connector
01B4036  per meter heated sample line PSP4M4/6, operating temperatures max. 200 °C with exchangeable PTFE hose 4/6 mm to jut out 0,5 m (cold end), 
incl. 3 extra wire for the probe heater, PT100 position 0,6 m mounted from electrical inlet Silicone foam heat insulation with Nylon net, power 
220-240V 50/60Hz, 110W/m 
Max. 12 meter length at 230V/50Hz and 6 meter length at 115V/60Hz for PSS-5..-conditioing system with internal temperature regulator
01B4034W  beginning connection part I for sample line PSP-W4M4/6 with pipe end, for interchangeable tube 4/6, incl. PT100 and 1,5 m extension cable 
axial at the back, with 7 pins plug
01B4037W end connection part K for sample line PSP-W4M4/6 with spec. pipe end, for interchangeable tube 4/6, 0,5 m extension cable axial at the back, 
with 7 pins connector
01B4036W  per meter heated sample line PSP-W4M4/6, operating temperatures max. 200 °C with exchangeable PTFE hose 4/6 mm to jut out 0,5 m (cold 
end), incl. 3 extra wire for the probe heater, PT100 position 0,6 m mounted from electrical inlet. Silicone foam heat insulation with corrugated 
hose envelope out of PA, power 220-240V 50/60Hz, 110W/m.  
Max. 12 meter length at 230V/50Hz and 6 meter lenfth at 115V/60Hz for PSS-5..-conditioing system with internal temperature regulator
40S9090  aluminium-composite carrying case PSP to take portable gas sample probe PSP4000H... and max. 5 m heated sample line PSP4M4/6 or max. 8 
m PSP-W4M4/6, dimension 530 x 420 x 300 mm
1)
 Please pay attention to the characteristic feature of ceramic in case of high and changing temperatures! 
Temperature controller see data sheet 2-6.2, 2-5.1 and 2-5.1.2 
Portable gas conditioning system see data sheet 4-2.1 und 4-2.1.2 
Portable oxygen analyser see data sheet 9-1.1 und 9-1.1.1 
Pre-filter SP1
2.18
NPT1/4"
Ø4,8
SW15
Ø30
M&C TechGroup Germany GmbH • Rehhecke 79 • 40885 Ratingen • Germany 
info@mc-techgroup.com • www.mc-techgroup.com • Fon +49 2102 935-0 • Fax +49 2102 935-111
150*
172
Technical specications and illustrations are without 
obligation, subject to modications. 09.96/06.06