MP-F10
Embracing Challenge
Analytical Bellows Pump
Series MP®
Version MP-F05, MP-F10, MP-F05/R, MP-F10/R
Special Features
Corrosion resistant
100% lubricant free
Gas tight
Maintenance free
Long service life
variable connection possibilities
Also with integrated bypass valve in the
pump head for adjustment of the pump
capacity
Application
This bellows pump MP-F is suitable for corrosive gases. It is constructed
especially for problems in the analysis technique.
Description
All sample contacting parts of the bellows pump MP-F are corrosion resistant. As option for piping the upper pump
head part is available in stainless steel.
The pump works absolutely lubricant free, so
gases remain analytically unchanged. Due to
a special bellows and valve system, the pump
operates maintenance-free with a long service life. The simple valve design guarantees
low maintenance costs.
The pump is available in 230V or 115V and in
two capacity variants.
For adjustment of the pump capacity a needle valve is built into the pump head of the
MP-F../R as an internal bypass.
Optional a needle valve can be build
into the pump-head to adjust the
flow rate.
Gas connection can be effected from above
or laterally. The pump head also can be rotated and mounted in 90° steps.
Technical specifications and illustrations are without
obligation, subject to modifications. 09.96/11.06
M&C TechGroup Germany GmbH • Rehhecke 79 • 40885 Ratingen • Germany
info@mc-techgroup.com • www.mc-techgroup.com • Fon +49 2102 935-0 • Fax +49 2102 935-111
10.9

Dimensions
Pump MP-F
Dimensions in mm
Performance characteristics MP-F
Working pressure for MP-F 10 max. 2,5bar abs.
10.9
M&C TechGroup Germany GmbH • Rehhecke 79 • 40885 Ratingen • Germany
info@mc-techgroup.com • www.mc-techgroup.com • Fon +49 2102 935-0 • Fax +49 2102 935-111
Technical specifications and illustrations are without
obligation, subject to modifications. 09.96/11.06

Technical Data
Bellows pump MP-F05
MP-F05/R MP-F10 MP-F10/R
Integrated needle valve no yes no yes
Part No. 230V 50Hz 05 P 1000
Part No. 115V 60Hz 05 P 1000a
05 P 1010 05 P 1005 05 P 1015
05 P 1015a 05 P 1005a 05 P 1015a
Degree of protection IP 55 EN 60529
Capacity max. 320 Nl/hr without pressure 600 Nl/hr without pressure
Operating pressure max. 0,4 - 2,2 bar abs. max. 0,2 - 3,2 bar abs.
Sample temperature -30 to +140 °C
Ambient temperature +10 to +40 °C / 0 to +40 °C for dry sample gas
Storage temperature -15 to +60 °C
Current consumption 230V/115V 0,95A/1,8A
Power consumption 90W
cos φ 230V : 0,94 / 115V : 0,98
Gas connections G1/4" i DIN ISO 228/1
Material of sample
PTFE, PFA, FEP, (+PVDF for type /R)
contacting parts
Operating mode 100% continous duty, start of the pump only without pressure
Electrical equipment standard EN 60204-1
Weight 4,7 Kg
Options
05 P 1050 Mounting bracket with 4 anti-vibration pads for bellows pump MP-F
05 P 1060 Extra charge for upper pump head of bellows pump MP-F out of stainless steel
05 P 1070 Extra charge for upper pump head of bellows pump MP-F../R out of stainless steel with needle valve out of PVDF
Technical specifications and illustrations are without
obligation, subject to modifications. 09.96/11.06
M&C TechGroup Germany GmbH • Rehhecke 79 • 40885 Ratingen • Germany
info@mc-techgroup.com • www.mc-techgroup.com • Fon +49 2102 935-0 • Fax +49 2102 935-111
10.9