Sample tubes for series SP®
Embracing Challenge
Sample Tubes for
Gas Sample Probes Series SP®
with G 3/4”-connection thread
Special Features
Sampling of dust loaded process gases
Small volume, fast response time
Easy mounting and maintenance
Self-regulated electrical heater
Alarm contact for low temperature
Outdoor mounting with protective cover
Insitu probe tube optional
Application
The M&C sample tubes are used in combination with the M&C gas sample probes series
SP® for point selective continuous gas sampling in processes with low dust loadings.
Description
The M&C probe sample tubes SP210/SS and
SP2000/... are selected according to the specific applications. Influencing process parameter are the gas composition, dust content,
water vapure saturation, temperature, pressure and gas velocity.
Among the standard length “L1” other lengths
up to “L max” are available on request.
For applications with low sample gas flow,
sample tubes SP2000/SS-Vm are equipped
with volume displacers to decrease the retention time.
Gas sampling downstream a wet scrubber with a high content of water carried
out with the M&C sampling tube SP32,
equipped with an integrated demister for
liquid drop collection.
Depending on the selected material, the M&C
sample tubes are equipped with a welded
thread adapter or a support adapter. They
are partly made of different material than the
tubes, depending on fabrication. See below
table.
The connection thread enables an easy
mounting into the mounting flange of the
M&C gas sample probes.
Further sampling accessories:
For a high dust load Pre-filter V20.., V12...
For lower deviation of dew point on process
side heated sample tubes SP30, SP35.
Technical specications and illustrations are without
obligation, subject to modications. 09.96/06.11
M&C TechGroup Germany GmbH • Rehhecke 79 • 40885 Ratingen • Germany
info@mc-techgroup.com • www.mc-techgroup.com • Fon +49 2102 935-0 • Fax +49 2102 935-111
2.14
Dimensions
Sample tubes Series SP
d1
®
Sample tube SP210SS / SP2000... / CR-N with welded thread connection
L1 / L max
Sample tube SP2000/ CR-2(20) /AO for >1300 C with support adapter
Sample tube SP32 with demister for gas sampling behind wet scrubber
G
EM
DEMISTER
Dimensions in mm
Technical Data
M&C Probe
sample tube
Type
SP2000/PV 20S9070 90 PVDF/ PTFE-gfr. 1000 1500 G 3/4"a 25/21 50
SP32 20S9280 90 PVDF/ PTFE-gfr. 800 800 G 3/4"a 50/44 50
SP2000/T 20S9083 160 PTFE/ PTFE-gfr. 500 500 G 3/4"a 25/15 33
SP2000/Ti 20S9075 400 Titane 1000 2500 G 3/4"a 25/22 37
SP210/SS 02S9200 600 stainl. steel 316Ti 1000 2000 G 3/4"a 12/10 37
SP2000/SS 20S9065 600 stainl. steel 316Ti 1000 2500 G 3/4"a 25/22 37
SP2000/SS-Vm 20S9067 600 stainl. steel 316Ti 1000 2500 G 3/4"a 25/06 37
SP2000/HC 20S9090 900 Hastelloy C4 1000 2500 G 3/4"a 25/22 37
SP2000/KA 20S9080 1300 Kanthal / SS 316Ti 1000 1500 G 3/4"a 27/20 37
SP2000/IN 20S9077 1100 Inconel 1100 2000 G 3/4"a 25/22 37
SP2000/CR-2* 20S9098 1400 Cr AL2 O
SP2000/CR-20* 20S9099 1400 Cr AL2 O3 / Hastelloy C4 1200 1200 G 3/4"a 22,5/13 50
SP2000/CR-N 20S9086 1400 Silicon nitride-ceramic /
SP2000/AO + ↓ 20S9385 1800 Aluminiumoxyde2) / 1000 1500 24/18
Adapter 20S9395 (600) / stainless steel 316Ti G 3/4"a 50
Adapter 20S9397 (900) / Hastelloy C4 G 3/4"a 50
Part. No. Temperature
max. °C
Material
Tube / connection part
/ Hastelloy C4 900 900 G 3/4"a 22,5/13 50
3
1.4571
Length
„L1“
mm
Length
1)
„L max“
mm
1000 on re-
quest
Connection
thread
„G“
Tube ø
o/i „d1“
mm
G 3/4"a 22/29 50
Connection
ø a „EM“
mm
* Sample tube with support adapter. Max.Temperature concern the area of the support adapter on approx. 200 mm length depend on material 600/900 °C.
1)
Standard
2)
Please pay attention to the characteristic feature of ceramic in case of high and changing temperatures!
Other materials or executions on request.
For further technical information see Sample Probes SP 210 / 2100 / 2000.
2.14
M&C TechGroup Germany GmbH • Rehhecke 79 • 40885 Ratingen • Germany
info@mc-techgroup.com • www.mc-techgroup.com • Fon +49 2102 935-0 • Fax +49 2102 935-111
Technical specications and illustrations are without
obligation, subject to modications. 09.96/06.11