FP-70P190-D
Embracing Challenge
Universal bypass lter series FP®
for liquid ltration
Version FP-70P200-D, FP-70P190-D, FP-200P190-D
Special Features
Universal in use
Simple construction
Simple assembly and maintenance
Condition of lterelement visible from
outside
Wall mounting
Application
The M&C universal bypass filter is used in
liquid analysis for filtration of low sample flow
rates. Two different filtration methods are
available:
1. Filter Type FP-70P200-D:
Filtration of a liquid flow in a set-
tling area.
2. Filter Type FP-70 (200) P190-D:
Filtration of a liquid flow with self-
cleaning effect through a bypass
system with fast flow rate over
the active filter surface.
Description
The basic construction of the bypass filter
corresponds with the line of universal filters
which are used for the gas filtration. The coarse sieve filter element is supplied with a pore
size of 70 or 200 µm and is manufactured
out of PP including the supporting pillar. The
filter element is screwed into the filter head
together with the filter element holder.
Through the glass filter body, the condition of
the filter element is visible at any time without
dismantling the filter. For changing the filter
elements no tools are necessary.
The optimal positioning of the o-ring guarantees a safe sealing of the filter body to the
filter head. The sample outlet may be turned
around by 180 ° at the wall mounting bracket
so that a flexible handling of the mountage
is possible according to different local conditions. The sample connections are located
in the filter head and in the lower part of the
filter glass.
Respective tube connectors and GL25 adaptors DN4/6, 6/8, 8/10 or 10/12 are optionally
available.
In order to obtain the desired self-cleaning
effect, the bypass filters FP-70 (200) P190-D
should be operated with a minimum bypass
quantity of 300 l/h.
Technical specications and illustrations are without
obligation, subject to modications. 09.96/11.06
M&C TechGroup Germany GmbH • Rehhecke 79 • 40885 Ratingen • Germany
info@mc-techgroup.com • www.mc-techgroup.com • Fon +49 2102 935-0 • Fax +49 2102 935-111
7.12
Dimensions
Filter FP-70P200-D
Filtration in a setting area
84
54
290 60
13
190
58
42
sample in
G3/8"
ø 5
G1/4"
sample
out
Filter FP-70-P190-D / FP200P190-D
Filtration with self-cleaning effect
through bypass system
58
42
bypass
G3/8"
60 290
13
190
5
G1/4"
sample
out
connection GL25
bypass
Dimensions in mm
sample in
Flow rate in dependence of inlet pressure
1600
1400
1200
1000
800
l/hr
600
400
200
0
0 bar 0,2 bar 0,5 bar 1,0 bar 1,5 bar 2,0 bar
Bypass
Sample
Technical Data
Liquid bypass filter series FP® FP-70P200-D FP-70P190-D FP-200P190-D
Part No. 02F1400 02F1440 02F1450
Filtration in a settling area yes no
Filtration with self-cleaning-effect no yes
Filter element fineness 70 µm 200 µm
Bypass-connections G3/8" i DIN ISO 228/1 and GL25-12 GL25-12 and G3/8" i DIN ISO 228/1
Sample connection G1/4" i DIN ISO 228/1
Max. pressure at 20 °C max. 2 bar abs. or max. 5 bar abs. with GL-connecting adapter
Bypass flow max. 1500 l/hr
Sample max. 180 l/hr
Sample temperature max. 80 °C
Ambient temperature max. 80 °C
Filter surface 180 cm
Volume 100 ml
Weight approx. 650 g
Method of mounting wall mounting
Material of sample contacting parts PVDF, PP, glass, FPM
2
connection GL25
7.12
M&C TechGroup Germany GmbH • Rehhecke 79 • 40885 Ratingen • Germany
info@mc-techgroup.com • www.mc-techgroup.com • Fon +49 2102 935-0 • Fax +49 2102 935-111
Technical specications and illustrations are without
obligation, subject to modications. 09.96/11.06