M&C TechGroup ECP3000 Datasheet

ECP 1000- G
Embracing Challenge
Peltier-Gas Cooler Series ECP®
Version ECP1000 with 1x 150 Nl/h Version ECP2000 with 2x 150 Nl/h Version ECP3000 with 1x 350 Nl/h
Special Features
With Jet-Stream heat exchanger avail-
able in three standard materials
Ambient temperature up to +50 °C
to +15 °C
Dew point stability ± 0,1 °C
With Alarm contact
Small dimensions, light-weight
Optimum reliability
Self-controlling
Application
ECP gas coolers are used in gas analy­sis to lower the dew point of humid to avoid condensate in the analyser. An extreme­ly stabel gas dew point avoids water vapour crosssensitivity and volumetric errors.
Description
The electronically controlled peltier cooler produced by M&C incorporates the “Jet­Stream” design of heat exchanger. This design induces condensate formation and guarantees optimum dew point reduction to a stable low value, eliminating the need for additional pre-drainage devices.
The condensate formed should be removed with a small peristaltic pump, simple trap or collection vessel. The sim­ple construction employed enables heat exchanges of different materials to be used depending on the application.
The operating status of the cooler is dis­played by three LED indicators, one each for over or under temperature alarm and one which pulsates showing the cooler is functioning correctly. The alarm status changes when the temperature deviates by ± 3 °C from the set point.
The compact lightweight design of this device makes it ideal for use in portable and compact continous sample conditioning systems.
Application example for ECP
1 Heated lter sample probe SP210-H or SP2000-H 2 Heated sample line 4M4/6 3 Cooler ECP1000 4 3-way ball valve 3L/PV-1 5 Peristaltic pump SR25.2 6 Diaphragm pump MP47 or MP06/12 or N5KP 7 Fine lter FP-2T-D with liquid alarm LA1 8 Aerosol lter CLF-5 /W optional according to application 9 Flow meter FM10 or FM40, 25-250 Nl/hr 10 Analysers f. e. PMA100
Technical specications and illustrations are without obligation, subject to modications. 10.96/06.06
10
3
ECP
sample gas IN
1 2
Alternative: trap with float or condensate collection vessel
M&C TechGroup Germany GmbH • Rehhecke 79 • 40885 Ratingen • Germany info@mc-techgroup.com • www.mc-techgroup.com • Fon +49 2102 935-0 • Fax +49 2102 935-111
+5°C
4
test gas
IN
condensate OUT
7
6
5
8
9
6.1
26
25
55
305
220
25
Cooler
ECP 2000
ON <C
>C
2xPG 11
GL 25
GL 18
Dimensions
17
220
30
275
136
68
200
180
11
6
63 137
215
2xPG 11
GL 25
GL 18
<C
ON
>C
Cooler
ECP 1000
305
45
25
220
Cooler
ECP 3000
ON
<C
>C
2xPG 11
GL 25
GL 18
ECP 1000
ECP 2000
ECP 1000
°C
10
Sample inlet dew point 50°C
Sample outlet dew point
5
50
100 150 Nl/h
Gas flow rate
Gas cooler with Part-No.
A Heat exchanger out of glass 01 K 1000
B Heat exchanger out of SS316Ti 01 K 2000
C Heat exchanger out of PVDF 01 K 3000
ECP 2000
°C
10
A
C
B
ECP 3000
Sample inlet dew point 50 °C
A
C
B
Sample outlet dew point
5
50
100 150 Nl/h
Gas flow rate
Gas cooler with Part-No.
A Heat exchanger out of glass 01 K 2100
B Heat exchanger out of SS316Ti 01 K 2200
C Heat exchanger out of PVDF 01 K 2300
ECP 3000
°C
10
Sample inlet dew point 50°C
Sample outlet dew point
C
A
B
Dimensions in mm
6.1
5
50
100 150 200 250 300 350 Nl/h
Gas flow rate
Gas cooler with Part-No.
A Heat exchanger out of glass 01 K 3100
B Heat exchanger out of SS316Ti 01 K 3200
C Heat exchanger out of PVDF 01 K 3300
M&C TechGroup Germany GmbH • Rehhecke 79 • 40885 Ratingen • Germany info@mc-techgroup.com • www.mc-techgroup.com • Fon +49 2102 935-0 • Fax +49 2102 935-111
Technical specications and illustrations are without obligation, subject to modications. 10.96/06.06
Loading...
+ 1 hidden pages