M&C TechGroup CLF-SS Datasheet

CLF-T
Embracing Challenge
Fluid Particle Filter Series CLF®
Version CLF-T, CLF-SS made out of special materials, for removal of aerosols from gases
Special Features
High retention rate of 99,99% for parti-
cles > 0,1µm
High chemical resistance of type CLF-T
applications
Condition of lter element CLF-T visible
from outside
Easy change of lter element
Wall mounting
Application
The M&C fluid particle filter CLF-.. is suitable for filtration of fluid particles of all types and is recommended for sample gases with an acid dew point above 100 °C. Examples are measurements in flue gas of heavy oil and black coal combustions.
The filter separates the aerosols (very fine fluid particles) which still pass the gas cooler. The most effective position of the CLF-.. filter is downstream the sample conditioning close to the flowmeter of the analyser.
Description
The filter element of the M&C fluid particle filter is constructed in two sections with a flow direction from the inside to the outside of the filter element. The inner, very fine, fibre layer binds the fluid particles suspended in the gas and leads them together with the gas flow to the outer, larger layer. On their way through the filter element, the very fine fluid particles accumulate with others and form droplets. The vertical flow direction and the force of gravity cause the droplets to drip into the filter pot.
The filter element remains fully effective even when completely saturated with fluid. If it is not effected by solid particles, the lifetime is nearly unlimited. The compressed micro­fibres are made with binding of PVDF in order to prevent influences on the sample gas.
The condition of the CLF-T filter is visible through the glass body without opening the filter.
The separated acid mist can continuously be discharged with an external mounted peri­staltic pump SR25.1 or a liquid drain AD-SS (option) connected by a GL25 or a G3/8“ adapter.
No tools are required to change the filter ele­ment. The optimised position of the O-ring always guarantees a safe sealing of the filter body to the filter head. The filter in- and out­let can be turned by 180 ° on the mounting bracket to achieve easy mounting and flexible adaption to local circumstances.
The filter is made out of PTFE/glass or stainless steel 316Ti.
Handle with care! Danger of acid burns!
Technical specications and illustrations are without obligation, subject to modications. 06.99/06.06
M&C TechGroup Germany GmbH • Rehhecke 79 • 40885 Ratingen • Germany info@mc-techgroup.com • www.mc-techgroup.com • Fon +49 2102 935-0 • Fax +49 2102 935-111
7.8
Dimensions
330
58 42
ø 5
13
G1/4"
L
Dimensions in mm
*
54
89
*Constructional size
Version: Measure L:
1
Drain:
ø 70
240
GL25
1
CLF-SSCLF-T 210
G3/8"i
Technical Data
Fluid particle filter CLF-T CLF-SS
Part No. 03F2100 03F2300
Material of sample contacting parts PTFE, glass, FPM stainless steel 316Ti, FPM
Gas pressure (∆P max. 1 bar) 0,2-2 bar abs. 0,2-26 bar abs.
Gas flow max. 300 Nl/hr
Differential pressure for a new filter element, with air, 20 °C
Sample temperature max. 100 °C
Ambient temperature 0 °C to +100 °C
Storage temperature -30 °C to +120 °C
Filter element 2-layer CLF-4
Retention rate 99,99 % for particles >0,1 µm
Filter dead volume 135 cm
Reservoir capacity for liquid 50 ml
Sample gas connection G 1/4"i DIN ISO 228/1
Drain connection GL25 cap G 3/8" plug
Type of mounting wall mounting
Weight approx. 0,8 kg approx. 2,2 kg
1 2,5 4,5 mbar 100 200 300 Nl/hr
3
7.8
M&C TechGroup Germany GmbH • Rehhecke 79 • 40885 Ratingen • Germany info@mc-techgroup.com • www.mc-techgroup.com • Fon +49 2102 935-0 • Fax +49 2102 935-111
Technical specications and illustrations are without obligation, subject to modications. 06.99/06.06