Vision & Skyline
Days to Ship 10 20
Unit Size
003 through 050 (040 to 050 plenum fans only) • •
065 (plenum fans only) •
Variable dimensioned units up to 92 inches tall • •
Unit Construction
Double-wall G90 galvanized construction as required • •
Painted cabinet • •
Solid galvanized or stainless steel liners, tread plate floor • •
Optional access doors or windows as required • •
Shipped whole or sectionalized as required • •
Light kit options • •
18 gauge outer panel options • •
Drain pans, drip pans • •
Base rail option as required • •
Draw-through or blow-through arrangements • •
Unit Section Types
All except face & bypass, blender, attenuator, • •
heat recovery, multizone
Face & bypass •
Fan Section Options
DWDI forward curved or airfoil fans: 106" max. cabinet width • •
Belt-drive plenum fans: 20", 27", 30", 33" and 40" • •
(Must be Class II with inlet and wheel guards.)
Belt-drive plenum fan: 54" •
Discharge arrangements: all • •
Drives: all in selection program, fixed or variable • •
Drives: ABB VFD on Vision only, see Rep for details •
No inlet vane option • •
Bearings: all standard. no optional • •
Mounts: spring, RIS or rigid; no seismic restraint option • •
Seismic restraint •
Motors: single-speed, high-efficiency ODP or TEFC; • •
115/230 volt,single-phase; 200, 230/460 & 575 volt, 3-phase
Motors: all standard & premium efficiency; no 2-speed, •
U-frame or explosion-proof motors
Days to Ship 10 20
Coil Section Options
Coil sizes: all available; medium, large or extended, • •
not staggered
Staggered coils, all sizes •
Coil options: all available on 5-day Coil Quick Ship program • •
Coil options: all available on 10-day Coil Quick Ship program •
Stainless steel casings, DX coils • •
Drain pans: standard galvanized or stainless steel • •
Coil section depths: all available • •
Not available: moisture eliminators, copper fins, 1" steam coils • •
Filter Section Options
Filter type: flat, angular,cartridge (no media) or bag (no media) • •
Media for bag filter •
Panel filters: ‘5700’ or PerfectPleat, 2" or 4" • •
Cartridge filters: Varicel or Varicel II, all efficiencies; •
no Varicel V
Mixing Box & Economizer Section Options
Plain or with flat or angular filters, with or without dampers • •
Destiny
Days to Ship 10 to 15
Unit Size
002 through 007 (horizontal arrangement only) •
LAH model nomenclature •
Unit Construction
Stainless steel drain pan •
Double wall construction •
Removable panels or hinged access doors •
Coil Options
Standard or high capacity chilled water coils •
1 or 2 row hot water coils (in reheat configuration) •
Motors
Single-speed, high-efficiency ODP, 230/460 volt, 1 or 3 phase •
Filter Section Options
2" flat throw-away only (filter track suitable for 4" filter) •
Air Handler Quick Ship Options
Vision & Skyline (continued)
Not seeing what you need?
Contact your McQuay representative for information on the wide range of additional offerings available with
standard factory lead times.