Touch Panel Switch
410 Series
Introduction
Touch Panel Switch is a wall panel built-in with Z-Wave Plus module. With its stylish design and
stable performance, the panel can be used to control house-hold electrical appliances like lamp, motor, coffee machine, TV set etc. It supports basic command classmulti channel command class and multi
channel association command class, also works as a repeater in a Z-Wave network. This product can
be included and operated in any Z-Wave network with other Z-Wave certified devices from any other
manufacturers.
Specifications
Power supply: 85~260VAC, 50/60Hz
Z-Wave frequency: 868.42MHz (EU), 865.2MHz (IN) or other frequency customized
Note: If an inductive load wired, please choose model MH-S411H. (LED load: <10A, inrush
current<165A/ 20ms)
Installation Instructions
IMPORTANT:
A qualified electrician with the understanding of wiring diagrams and knowledge of electrical
safety should complete the installation inside the main circuit box (normally outside your house).
Read all instructions and documentation and save for future reference.
Step1 Preparing
CAUTION: Cut off power supply at circuit breaker or fuse before installation to avoid fire, shock or
death!
Step2 Installation
Step 1: Separate the device into two parts: the
touch panel and the bottom.
Step 2: Insert all wires into the right terminals by
following the wiring diagrams as below,
and tighten screws.
Step 3: Secure the bottom part onto a junction box with screws, and then mount the touch panel back.
Step 4: Confirm the device is well mounted, power on and it is ready to operate.
Item Models Max Load
410 series
MH-S411 1*5A
MH-S412 2*5A
MH-S411H 1*10A
www.mcohome.com
User Manual
2
Wiring (standard strip length: 6-8mm)
MH-S411, MH-S411H MH-S412
Operation
INCLUDING the device into Z-Wave network:
1. Set controller into INCLUSION mode. Follow instructions provided by controller manufacturer.
2. Press and hold any key on the panel for 8 seconds or 3 clicks in quick succession.
Note: If inclusion is successful, all INDICATION LEDs on the panel will flash 4 times.
EXCLUDING the device from Z-Wave network:
1. Set controller into EXCLUSION mode. Follow instructions provided by controller manufacturer.
2. Press and hold any key on the panel for 8 seconds or 3 clicks in quick succession.
Note: If the exclusion is successful, all INDICATION LEDs on the panel will flash 4 times. The
exclusion will delete all association data.
Turning on/off the device:
The device can be controlled by:
Pressing any key. Sending commands through controller or gateway.the command classes which support this
function are Basic Command Class, Binary Command Class, Switch All Command Class, and Multi Channel Command Class.
Multi Channel Control:
The switch can be controlled by command “MULTI_CHANNEL_ENCAP” in the command
class “COMMAND_ CLASS_MULTI_CHANNEL”.
Refer to “Z-Wave Command Class”for detail information, or consult the information provided by
controller/ gateway manufacturer.
Byte Name
1
COMMAND_CLASS_MULTI_CHANNEL
2
MULTI_CHANNEL_CMD_ENCAP
3
Source End Point
4
Destination End Point
5
COMMAND_CLASS_SWITCH_BASIC or COMMAND_CLASS_SWITCH_BINARY
6
BASIC_SET/BASIC_GET or BINARY_SET/BINARY_GET
7
Value ( 0xFF -- ON 0x0 -- OFF )
Multi Channel Association:
To set association groups by the command “COMMAND_CLASS_MULTI_CHANNEL_
ASSOCIATION”.
www.mcohome.com
User Manual
3
The device supports several (key numbers +1) association groups (AG). The 1st AG is used for
reporting devices’ state to the controller if any changes happen. This group supports one Node, which suggested to be controller Node. The rest AGs are used for switching associated devicesand they
can support up to 5 nodes each.
AG NO. Function Explanation
0x01 Associate with gateway Send unsolicited reports to the gateway
0x02 Associate with Key 1
send Basic Set Command to associated devices
0x05 Associate with Key 2 if any
Multi-panels (up to 5 ) controlling one load
For example: Five MH-S411s and their Node IDs are: A-012, B-013, C-014, D-015, E-016
1. Wire the load to any of the panel.
2. Put all the other 4 panels NIDs: 013,014,015,016 into A’s AG 0X02
3. Put all the other 4 panels NIDs: 012,014,015,016 into B’s AG 0X02
4. Put all the other 4 panels NIDs: 012,013,015,016 into C’s AG 0X02
5. Put all the other 4 panels NIDs: 012,013,014,016 into D’s AG 0X02
6. Put all the other 4 panels NIDs: 012,013,014,015 into E’s AG 0X02
Scene Function:
1. Scene Response Device
As a Scene Response device, it supports “Scene Activation CC” and “Scene Actuator Conf
CC” ,which make the device can be added into any scene , and supports 255 Scene ID. In parameter
item 0x10, users can configure which external switch button will respond the scene CC.
2. Scene Activate Device
As a Scene Activate device, when pressing the switch button, it will send “Scene Activation” to
Association Group 1 (normally associated to the gateway) to activate corresponding scenes, and the
scene ID is set by configuration parameter. This function is disabled by default, to activate it, please
refer to the configuration parameter table item 0x11-0x16.
3. Central Scene Activate Device
As a Central Scene Activate device, it supports “Central Scene CC”. When pressing the switch
button, it will send “Central Scene Notification” to Association Group 1 (normally associated to
gateway). This function is always being activated and cannot be disabled.
Parameters Setting:
Add
Function Byte
Options Default
Remark
0x01
Reserve .
0x02
Switch state saved or
not when power
failure
1
0x00 not saved,switch will be off when
powered again
0x01 savedswitch will keep the same
state when powered again
0x01
www.mcohome.com
User Manual
4
0x03 ALL ON/ALL OFF 1
0x00 forbid ALL ON, forbid ALL OFF
0x01 forbid ALL ON, allow ALL OFF
0x02 allow ALL ON, forbid ALL OFF
0xFF allow ALL ON, allow ALL OFF
0xFF
0x04
LED Backlit
brightness level
1
0x00 LED disabled
0x01~0x0A Min level-Max level
>0x0A same level as 0x0A
0x0A
0x05
Key Mode 1
0x00 single click to switch on/off status
0x01 Key default as off state. When it is
turned on, then it will be turned off
automatically after a time period , which
can be set in item 0x06
0x02 Key default as on state. When it is
turned off, then it will be turned on
automatically after a time period , which
can be set in item 0x06
0x03 hold >3s then key is on, and off once
released
0X04 single click to switch on/off status +
hold >3s then key is on, and off once
released
0x00
This function
works for
corridor or
stairwell
situation.
0x06 Key On duration 2
0x00 infinite
1~65535 unit "sec"
0x00
0x08
Basic CC integration
setting
1
0x00 "Basic Set" received,key 1 responds;
"Basic Get" receivedkey 1 sends "Basic
Report"; key 1 will not send unsolicited
"Basic Report"(No Endpoint)to LifeLine
Association
0x01 "Basic Set" received,key 1 responds;
"Basic Get" receivedkey 1 sends "Basic
Report"; key 1 will send unsolicited "Basic
Report"No Endpointto LifeLine
Association
0x02 "Basic Set" receivedall keys
respond; "Basic Get" received,not reply
"Basic Report"; All keys will not send
unsolicited "Basic Report"No Endpoint
to LifeLine Association
0x03 "Basic Set" receivedall keys
respond; "Basic Get" receivedkey 1
sends "Basic Report"; All keys will not
send unsolicited "Basic Report"(No
Endpointto LifeLine Association
0x00
This parameter
works for
integration with
different
gateways/syste
ms. If do not
know how to
use, pls keep as
default.
www.mcohome.com
User Manual
5
0x10
Scene respond 1
0x00: Scene respond disabled
Bit0: =1 Key1 respond scene
=0 Key1 not respond scene
Bit1: =1 Key2 respond scene
=0 Key2 not respond scene
Bit7:4 Rev
0x00
0x11
Key1 Scene Activate
Mode Setting
1
0x00 Scene activate function disabled
0x01 One click key1 always activate scene
ID1 no matter what the status of key1 is.
0x02 One click key1,only activate scene
ID1 when key1's relay output is open
0x03 One click key1,only activate scene
ID1 when key1's relay output is close
0x00
0x12
Key1 Activate Scene
ID
1
0x00 Scene ID is invalid and will not send
scene activate command.
1~255 Scene ID
0x00
0x13
Key1 Activate Scene
Duration
1
0x00 Instantly
0x01~0x7F: Dimming durations from 1
second (0x01) to 127 seconds (0x7F) in
1-second resolution
0x80~0xFE: Specify dimming durations
from 1 minute (0x80) to 127 minutes
(0xFE) in 1-minute resolution.
0x00
0x14
Key2 Scene Activate
Mode Setting
1
0x00 Scene activate function disabled
0x01 One click key2 always activate scene
ID1 no matter what the status of key2 is.
0x02 One click key2,only activate scene
ID1 when key2's relay output is open
0x03 One click key2,only activate scene
ID1 when key2's relay output is close
0x00
0x15
Key2 Activate Scene
ID
1
0x00 Scene ID is invalid and will not send
scene activate command.
1~255 Scene ID
0x00
0x16
Key2 Activate Scene
Duration
1
0x00 Instantly
0x01~0x7F: Dimming durations from 1
second (0x01) to 127 seconds (0x7F) in
1-second resolution
0x80~0xFE: Specify dimming durations
from 1 minute (0x80) to 127 minutes
(0xFE) in 1-minute resolution.
0x00
www.mcohome.com
User Manual
6
0x20
Scene respond
ID 1-50
1
0x00: Scene respond disabled
Bit0: =1 Key1 respond scene
=0 Key1 not respond scene
Bit1: =1 Key2 respond scene
=0 Key2 not respond scene
Bit7:4 Rev
0x00
Valid only when
the default is
0X00 for
parameter 0X10
0x21
Scene respond
ID 51-100
1 0x00
0x22
Scene respo
nd
ID 101-150
1 0x00
0x23
Scene respond
ID 151-200
1 0x00
0x24
Scene respond
ID 201-250
1 0x00
FF Factory setting 1 0x55 restore factory setting write only
Restoring Factory Settings
Press 10 times of any button or exclude the device from Z-Wave network, the factory setting will be
restored.
SAFETY NOTICE
1. Flush-mount only into a UL/ETL/CE certified plastic junction box. The minimum size should be
86*86*60mm, minimum Volume is 443cm3.
2. Use Copper Conductors Only.
3. CAUTION - Risk of Electric Shock - More than one disconnect switch may be required to
de-energize the equipment before servicing.
1-year Limited Warranty
We warrant this product to be free from defects in material and workmanship under normal and proper use for one year from purchase date of the original purchaser. We will, at its option, either repair or replace any part of its products that prove defective by reason of improper workmanship or materials. THIS LIMITED WARRANTY DOES NOT COVER ANY DAMAGE TO THIS PRODUCT THAT RESULTS FROM IMPROPER INSTALLATION, ACCIDENT, ABUSE, MISUSE, NATURAL DISASTER, INSUFFICIENT OR EXCESSIVE ELECTRICAL SUPPLY, ABNORMAL MECHANICAL OR ENVIRONMENTAL CONDITIONS, OR ANY UNAUTHORIZED DISASSEMBLY, REPAIR OR MODIFICATION. This limited warranty shall not apply if: (i) the product was not used in accordance with any accompanying instructions, or (ii) the product was not used for its intended function. This limited warranty also does not apply to any product on which the original identification information has been altered, obliterated or removed, that has not been handled or packaged correctly, that has been sold as second-hand or that has been resold contrary to Country and other applicable export regulations.