MCOHome A8-9 User Manual

www.mcohome.com User Manual
9 in 1 Multi-Sensor
A8-9
MCOHome A8-9 is a Z-Wave enabled multiple environmental monitoring sensors, with 3.5 inch TFT
PM2.5, CO2, VOC, PIR, illumination, Noise, Smoke sensors. Device can be added into any Z-Wave network, and is compatible with any other Z-Wave certified devices.
Temperature: 0~50℃
Humidity: 0%RH~99%RH
PM2.5: 0~500ug/m3
CO2: 0~5000ppm
VOC: 0-64000ppb
PIR: 0 or 1 Detection angle up to 120°
Illumination: 0~40000Lux
Noise: 30dB~100dB
Smoke: 0 or 1
Specification
Power Supply: DC12V
Self-dissipation:<3W
Work environment:-20~+60 <99%RH
(Non-condensation)
Dimension: 110* 110*32mm
Hole Pitch: 60mm or 82mm
Housing: Tempered glass+ PC Alloy
Installation: Wall-mounted (Vertical)
Safety Information
To protect yourself and others from danger and to protect the device from damage, please read the
safety information before using it.
Important!
A qualified electrician with the understanding of wiring diagrams and knowledge of electrical
safety should complete installation following the instructions.
Before installation, please confirm the real voltage complying with the device’s specification.
Cut off any power supply to secure the safety of people and device.
During installation, protect the device from any physical damage by dropping or bumping. If
happens, please contact the supplier for maintenance.
Keep the device away from acid-base and other corrosive solids, liquids, gases, to avoid damage.
Avoid overexertion during operation, to protect device from mechanical damage.
Read all instructions and documentation and save for future reference.
MCOHome Technology Co., Ltd 1
www.mcohome.com User Manual
Installation &Wiring
Location:
Device is suggested to be installed indoor, a place with around 1.5m height above the floor where
represents the average CO2 concentration. It should be away from direct sunlight, any cover, or any
heat source, to avoid false signal for temperature control.
Notice!
1. Device must be wall-mounted vertically. Do not lay it flat
or upside down while working.
2. Do not mounted it in a wind gap, or cover its bottom,
which may affect the detected data.
Step 1:Remove the steel frame from the backside of the device, and then fix it onto the installation
box with 2 screws.
Step 2:Wire the adaptor.
Step 3:Put the device back onto the steel frame, it will attach with the frame firmly by built-in
magnets.
Step 4:Check the installation and power, the device is ready for work.
Operation
Power on/ power off
Wire the adaptor and the device is powered on. It will display all detected information by the sensors.
Display interface
Hold Key F1 can switch among the following 4 display interfaces:
1. Data detecting: display all sensors’ data
2. Network: Z-Wave Add/Remove
3. Data calibration: to calibrate the detected data manually
4. Local time setting
Z-Wave Operation
Note: A Security Enabled Z-Wave Controller must be used in order to fully utilize the product.
Add &Remove Z-Wave network
Activate Add/Remove mode in the gateway. When device is powered on, hold F1 to choose
interface for Add or Remove Z-Wave network.
Click F2 five times until turns blue.
MCOHome Technology Co., Ltd 2
www.mcohome.com User Manual
Hold F2 and the device enters into learning mode, then turns blue and the device is added
into Z-Wave network.
Follow the same steps to remove the device from network.
Association Group
Device supports 1 association group:
AG
identifier
0x01 1
Max
Node ID
Command Classes Trigger situation
Detected value will be reported according to:
1, PM2.5 The value difference between current value
and previous reported value >0x01 set value, set value 0;
2, CO2 The value difference between current value
and previous reported value> 0x02 set value, set value0;
3, Temperature The value difference between current
value and previous reported value > 0x03 set value, set value0;
4, Humidity Thevalue difference between current
value and previous reported value > 0x04 set value, set value0;
5, VOC The value difference between current value
and previous reported value > 0x05 set value, set
COMMAND_CLASS
_SENSOR_MULTIL
EVEL_V5,
SENSOR_MULTILE
VEL_REPORT_V5
value0;
6, Illumination The value difference between current
value and previous reported value > 0x06 set value, set value0;
7, Noise The value difference between current value
and previous reported value > 0x07 set value, set value0;
8, PIR The current state is different from previous reported state, set value0;
9, Smoke The current state is differentfrom previous reported state, set value0;
10, Smoke IntervalReport Timer set value: 0x0A and set value0;
11, PIR IntervalReport Timer set value: 0x0B and set value0;
12, PM2.5 IntervalReport Timer set value: 0x0C and set value0;
13, CO2 IntervalReport Timer set value: 0x0D and set value0;
14, Temperature IntervalReport Timer set value:
MCOHome Technology Co., Ltd 3
www.mcohome.com User Manual
0x0E and set value0;
15, Humidity IntervalReport Timer set value: 0x0F and set value0;
16, VOC IntervalReport Timer set value: 0x10 and set value0;
17, Illumination IntervalReport Timer set value: 0x11 and set value0;
18, Noise IntervalReport Timer set value: 0x12 and set value0;
COMMAND_CLASS
_DEVICE_RESET_L
OCALLY,
DEVICE_RESET_LO
CALLY_NOTIFICAT
ION
Command Class supported by the device: ( Supports S2 unauthenticated level)
COMMAND_CLASS_VERSION,
COMMAND_CLASS_MANUFACTURER_SPECIFIC,
COMMAND_CLASS_DEVICE_RESET_LOCALLY,
COMMAND_CLASS_POWERLEVEL,
COMMAND_CLASS_ASSOCIATION,
COMMAND_CLASS_ASSOCIATION_GRP_INFO,
COMMAND_CLASS_CONFIGURATION,
COMMAND_CLASS_SENSOR_MULTILEVEL
COMMAND_CLASS_FIRMWARE_UPDATE_MD
Command Class supported by the device: (Not supports S2)
COMMAND_CLASS_ZWAVEPLUS_INFO,
COMMAND_CLASS_TRANSPORT_SERVICE_V2,
COMMAND_CLASS_SECURITY_2,
COMMAND_CLASS_SUPERVISION
Restore Factory Setting
1, Press & hold F1 to enter Z-Wave setting interface, then press & hold F1 again to enter parameters
setting interface;
2, Press & hold F2 to enter setting interface and select “default”;
3, Click F2 3 times and displays “OFF”-->“ON”-->“OK”-->“OFF”, factory setting is restored.
Data Calibration
Hold F1 to choose interface for data calibration. Then hold F2 to switch among the sensors.
Choose one and click F2, F1 to change the data. After finished, hold F1 can return data detecting
interface.
Factory setting restored
MCOHome Technology Co., Ltd 4
www.mcohome.com User Manual
Local time setting
Hold F1 to choose interface for local time setting. Then hold F2 to switch among
“Hour-Minute-Second-Year-Month-Date”. Click F2, F1 can change the data of flashing item. After
finished, hold F1 can return data detecting interface.
Parameters table
Num
ber
0x01 PM25_Delta_Level 1
0x02 CO2_Delta_Level 1
0x03 Temp_Delta_Level 1
0x04 Humidity_Delta_Level
0x05 VOC_Delta_Level 1
0x06
0x07 dB_Delta_Level 1
0x08
0x09 SMOKE_Delta_Level 1
0x0A
0x0B
0x0C
0x0D
Name Size
Lux_Delta_Level
PIR_Delta_Level
Smoke_Timer 2
PIR_Timer
PM25_Timer 2
CO2_Timer 2
Description Default Possible
=0 Turn off report
>=1 Report when change >
n * 1ug/m3
=0 Turn off report
>=1 Report when change >
n * 5ppm
=0 Turn off report
>=1 Report when change >
n*0.5℃
=0 Turn off report
1
>=1 Report when change >n%
=0 Turn off report >=1-127*5ppb Reportchange
=0 Turn off report
>=1 Report when change >
2
n*1 Lux
=0 Turn off report
>=1 Report when change >
n*1dB
=0 Turn off report
1
=1 Report change
=0 Turn off report =1 Report change
=0 Turn off report
>=35 Report every n*1s
interval
=0 Turn off report
>=35 Report every n*1s
2
interval
=0 Turn off report
>=35Report every n*1s
interval
=0 Turn off report
>=35 Report every n*1s interval
value
0 0-127
0 0-127
0 0-127
0 0-127
0 0-127
0
0 0-127
0
1 0-1
60
60
120 0,35-32767
120 0,35-32767
0-32767
0-1
0,35-32767
0,35-32767
MCOHome Technology Co., Ltd 5
www.mcohome.com User Manual
0x0E Temp_Timer 2
0x0F Humidity_Timer 2
0x10 VOC_Timer 2
0x11 Lux_Timer 2
0x12 dB_Timer 2
0x2F Temp. unit 1
=0 Turn off report
>=35 Report every n*1s interval
=0 Turn off report
>=35 Report every n*1s interval
=0 Turn off report
>=35 Report every n*1s interval
=0 Turn off report
>=35 Report every n*1s interval
=0 Turn off report
>=35 Report every n*1s interval
=0 ℃ =1 ℉
180 0,35-32767
180 0,35-32767
180 0,35-32767
300 0,35-32767
300 0,35-32767
0 0-1
0 ~ 127:
0x32 T_OffSet 1
0x33 RH_OffSet 1 n-20=(-20~20)% 20 0~40
0x34 CO2_OffSet 2 (n-500)=(-500~500)ppm 500 0~1000
0x35 PM2.5_OffSet 1
0x36 Lux_OffSet 2 n-5000=(-5000~5000)lux 5000 0~10000
0x37 VOC_Correct 1
0x38 dB_Correct 1 (n-50)=-50~50 50 0~100
0xFF Write Only 1
((n-100)/10)=(-10~2.7)℃
-128 ~ -1:
((156+n)/10)=(2.8~15.5)℃
0 ~ 127:
n-100=(-100~27)ug/m3
-128 ~ -1:
156+n=(28~155)ug/m3
0 ~ 127:
n-100=(-100~27)ppb
-128 ~ -1:
156+n=(28~155)ppb
==0x55 Restore factory setting ==0xAA Restore default para.
100 -128-127
100 -128-127
100 -128-127
MCOHome Technology Co., Ltd 6
www.mcohome.com User Manual
1-year Limited Warranty
MCOHome warrants this product to be free from defects in material and workmanship under normal and proper use for one year from purchase date of the original purchaser. MCOHome will, at its option, either repair or replace any part of its products that prove defective by reason of improper workmanship or materials.THIS LIMITED WARRANTY DOES NOT COVER ANY DAMAGE TO THIS PRODUCT THAT RESULTS FROM IMPROPER INSTALLATION, ACCIDENT, ABUSE, MISUSE, NATURAL DISASTER, INSUFFICIENT OR EXCESSIVE ELECTRICAL SUPPLY, ABNORMALMECHANICAL OR ENVIRONMENTAL CONDITIONS, OR ANY UNAUTHORIZED DISASSEMBLY, REPAIR OR MODIFICATION. This limited warranty shall not apply if: (i) the product was not used in accordance with any accompanying instructions, or (ii) the product was not used for its intended function. This limited warranty also does not apply to any product on which the original identification information has been altered, obliterated or removed, that has not been handled or packaged correctly, that has been sold as second-hand or that has been resold contrary to Country and other applicable export regulations.
MCOHome Technology Co., Ltd 7
Loading...