Installation guide for Alarm Receiver Exprecium
Contents
Introduction.................................................................................................................................................................................................................3
Main features.............................................................................................................................................................................................................3
Content of disk : Drivers & Utilities.........................................................................................................................................................................3
Installing the Exprecium Card..................................................................................................................................................................................3
Installing drivers and utilities software.....................................................................................................................................................................4
DOS users.............................................................................................................................................................................................................4
Using COMIRQ utility..........................................................................................................................................................................................4
Installing Windows 95 drivers..............................................................................................................................................................................5
Installing Windows 98 drivers..............................................................................................................................................................................5
Using WINCOM utility.........................................................................................................................................................................................6
Setting up your Exprecium........................................................................................................................................................................................7
Physical characteristics of Exprecium..................................................................................................................................................................10
Size......................................................................................................................................................................................................................10
Buffer memory....................................................................................................................................................................................................10
External battery connector..................................................................................................................................................................................10
Buzzer Alert/Warning.........................................................................................................................................................................................10
Formats and characters transmitted......................................................................................................................................................................11
Receiving.............................................................................................................................................................................................................11
Listen-in, Two way voice....................................................................................................................................................................................11
Transmission to computer and printer in EXPRECIUM Native mode..........................................................................................................11
EXPRECIUM Error and Warning messages sent to Printer port and PC......................................................................................................13
Transmission to computer and printer in Ademco 685 / Surgard emulation mode........................................................................................13
Messages from EXPRECIUM printer port.......................................................................................................................................................13
Transmission rate...............................................................................................................................................................................................13
Warranty..................................................................................................................................................................................................................14
Legal compliance and Warning..............................................................................................................................................................................14
United States Regulation FCC Warning.......................................................................................................................................................14
EC Declaration of Conformity............................................................................................................................................................................15
Europe EN41003 Warning Application Note 48, Issue 5.................................................................................................................................15
Technical data sheet for Exprecium.......................................................................................................................................................................17
MCDI Inc. Internet: http://www.mcdi.com 86 Claude-Champagne Avenue, Montreal, QC, Canada H2V 2X1 Telephone: +514-481-1067 Fax: +514-481-1487
Page 3
Page 3
Installation guide for Alarm Receiver Exprecium
Introduction
EXPRECIUM is a full format PC-based alarm receiver card. With two phone line per board, Eprecium gives you the power to turn your PC into a powerful alarm receiver. Starting with one board, you can add boards as your Central grows.
With large size memory, fast modem circuit, improved PC bus interface and Caller ID function, Exprecium adds a new dimension to Alarm Receiving and PC Integrated Monitoring Station.
The Exprecium receiver card carries a five year limited warranty.
Main features
PCI bus interface, 2/3 lenght card.
Plug & Play compatible with Dos, Windows 95 and Windows 98.
Flash memory for easy firmware update, realtime clock, storage of events and parameters.
2 phone lines per card, direct printer output, on-board buzzer.
May share PC with TLR and TLR+ Receiver Card.
Supports most popular formats including SIA and Contact ID.
Up to 1800 event buffer kept in a non volatile memory.
No logical account limitation.
and much more ...
System Requirements
Ensure that your IBM PC-compatible computer has the following :
1. An Intel 486, Pentium, Pentium Pro, Pentium II, or compatible processor with a Plug & Play Bios.
2. 8Mb or more of system memory for DOS system. For Windows 95 or 98, minimum requirements recommended by Microsoft.
3. MSDOS 6.22, Windows 95 or Windows 98 operating systems.
4. An empty PCI expansion slot for each Exprecium Receiver Card to be installed.
Content of CDROM disk: Drivers & Utilities
Windows 95 & 95 drivers : OXMEP.SYS OXMF.SYS OXMF.VXD OXMFUF.SYS OXPCI.INF OCPCI2.INF
OXSER.INF OXSER.SYS OXSER.VXD OXSERUI.DLL OXUI.DLL File name Description XPRECIUM.EXE Configuration program to configure your Exprecium or upgrade itsfirmware.
Can be used in DOS or Windows. XPRECIUM.BIN Binary file used to download firmware into the Exprecium card. COMIRQ.EXE Use to check specific Exprecium card in DOS environment. Allow you to
see incoming raw signals received. WINCOM.EXE Same as COMIRQ but for Windows environment only. WSCOM.EXE Communication module to be used with SAMM10 and WINSAMM.
Installing the Exprecium Card
1. Shut down the computer and remove the AC power cord.
2. Open the computer case to gain access to the inside. Touch the metal chassis of the computer to drain off any static electricity
before touching a board. Static electricity can damage the components inside a computer or on a printed circuit board.
3. Locate an empty PCI expansion slot into which you will install the Exprecium card. The selected slot must support PCI Plug &
Play devices. In most recent computers, all PCI slots have this ability. If you are not sure that your PC does, check the specification manual or contact your PC vendor. Remove the slot cover from the selected PCI slot. Retain the screw from the slot
cover, you will need it to secure the Exprecium Card to the computer chassis.
MCDI Inc. Internet: http://www.mcdi.com 86 Claude-Champagne Avenue, Montreal, QC, Canada H2V 2X1 Telephone: +514-481-1067 Fax: +514-481-1487
Page 4
Page 4
Installation guide for Alarm Receiver Exprecium
4. Remove the card from the anti-static bag. Record its serial number, you may be required to supply it in case of a support call.
Holding the edge of the card, carefully align the edge connector with the expansion slot. Push the board into the slot firmly and evenly until it is fully seated inside the slot.
5. Visually inspect the connection. If it does not appear to be correct, remove and re-install the board. Secure the card to the
computer’s chassis using the screw removed in step 3.
6. You can close the computer case at this point or wait until everything is functioning properly.
Installing drivers and utilities software
DOS users :
installed PCI card and assign a COM address and an IRQ to each card. Most PC displays a list of PCI devices installed at the power on. It may be necessary to press the PAUSE key to have a chance to look at it.
There is no need to install any specific DOS driver. Once you start your computer, the Bios will automatically detect the new
Here is an example :
PCI device listing …
Bus No. Device No. Func No. Vendor ID Device ID Device class IRQ
0 7 1 8086 7111 IDE Controller 14 0 7 2 8086 7112 Serial Bus Controller 11 0 9 0 6234 0001 Simple COMM Controller 15 0 9 0 6234 0001 Simple COMM Controller 5 0 11 0 1142 643D Display Controller NA ACPI Controller 9
EXPRECIUM Vendor Number : 6234 Device ID : 0001
In above example, two Exprecium Receiver cards are installed. One with IRQ 15 and a second one with IRQ 5. Notes : It is possible that your Bios assigns the same IRQ to more than one device. If your DOS application supports IRQ sharing this
Use the configuration utility called XPRECIUM.EXE, located on the media coming with your Exprecium card, to set the specific options. See section SETTING UP YOUR EXPRECIUM CARD for more information.
Using COMIRQ utility :
Also a debugging tool is provided. It is called COMIRQ.EXE To use it, type : COMIRQ X1 look at incoming signals on the first Exprecium card or
COMIRQ X2 look at incoming signals on the second Exprecium card or COMIRQ X3 look at incoming signals on the third Exprecium card … etc. up to COMIRQ X9
is not a problem. If your application does not have the ability to share IRQ’s, try the following steps :
• Move the Exprecium card to another free PCI slot to get a different IRQ assignment.
• Free more IRQ’s in your system by removing unused cards.
• Manually assign to the specific PCI slot a reserved IRQ in your Bios settings and install the Exprecium in that slot to avoid IRQ conflict. Refer to your PC manual or contact your service technician for
more information on how to manually assign IRQ’s.
The IRQ sharing issue is not a problem when using the Exprecium card under Windows 95 or 98 since Windows is managing IRQ’s internally and has the ability to share them.
MCDI Inc. Internet: http://www.mcdi.com 86 Claude-Champagne Avenue, Montreal, QC, Canada H2V 2X1 Telephone: +514-481-1067 Fax: +514-481-1487
Page 5
Installation guide for Alarm Receiver Exprecium
Here is an example of display provided by the COMIRQ utility :
COM D400 IRQ 5 : ANY INCOMING SIGNAL Hit "Space Bar" to send ACK ___________________________________________________________________________________ @<CR> @<CR> @<CR> 11:09 02/08 12 1234 51<CR> 11:09 02/08 12 1234 51<CR> 11:09 02/08 12 1234 51<CR> 11:09 02/08 12 1234 51<CR> @<CR> 11:09 02/08 12 4378 O66<CR> 11:10 02/08 12 4378 O66<CR> 11:10 02/08 12 1234 51<CR> @<CR> @<CR> ___________________________________________________________________________________ IRQ Number might Be Available : 3 5 10 11 <ESC> To exit --- <DEL> Clear screen --- Press "A" to enable <ACK>
The top line of the display indicates your Base address and IRQ setting. Press the letter “A” to acknowledge all signals. In the above example, the COM port address is D400 and the IRQ is 5. This is the information required to configure your DOS software.
Page 5
Installing Windows 95 drivers :
1. Power up the computer and allow it to boot into Windows 95. Windows 95 detects that you have added new hardware (Exprecium receiver card). The New Hardware Found dialog displays : PC SERIAL CONTROLLER. The Add New Hardware Wizard will detect an : OXCB950 Cardbus UART.
2. Insert your Exprecium CDROM disk in your CDRON drive and click NEXT to continue.
3. When asked to : “ Please insert the disk labeled ‘High-performance ports driver disk’ and then click OK “, click OK to continue.
4. The following message will be displayed : “The file ‘oxmf.vxd’ in high-performance ports driver disk could not be found”, click
BROWSE , in the Drive Section, select your CDROM drive then click OK.
5. The same dialog box will appear again. This time just click OK. Windows will complete the installation.
For each Exprecium card installed, Windows will create a new COM port starting at COM5 (COM1 to COM4 are reserved for your PC). The second card will be on COM6, the third one on COM7 and so on ...
Installing Windows 98 drivers :
1. Power up the computer and allow it to boot into Windows 98. Windows 98 detects that you have added new hardware (Exprecium receiver card). The New Hardware Found dialog displays : PC SERIAL CONTROLLER. The Add New Hardware Wizard will detect an : OXCB950 Cardbus UART, click NEXT to continue.
2. When asked to specify how to install the driver, select SEARCH FOR THE BEST DRIVER FOR YOUR DEVICE, and then click
NEXT .
3. Insert the CDROM DRIVERS & UTILITIES into the CDROM drive. In the Add New Hardware Wizard box, select CDROM DRIVES (as the location for the drivers) and press NEXT . The Install Disk dialog displays : ?:\OXPCI.INF press NEXT .
4. Windows will copy and install the required drivers for your Exprecium card. Click FINISH to let Windows complete the process.
For each Exprecium card installed, Windows will create a new COM port starting at COM5 (COM1 to COM4 are reserved for your PC). The second card will be on COM6, the third one on COM7 and so on ...
MCDI Inc. Internet: http://www.mcdi.com 86 Claude-Champagne Avenue, Montreal, QC, Canada H2V 2X1 Telephone: +514-481-1067 Fax: +514-481-1487
Page 6
Page 6
Installation guide for Alarm Receiver Exprecium
Using WINCOM utility :
Within Windows, double click on the WINCOM icon. Select SETTINGS and set the COM port to match the EXPRECIUM COM port. If you only have one Exprecium
installed in your system, the COM port address should be COM5. Then click OK. Do not change other parameters since they are already set to match your Exprecium card.
Function of each button : OPEN To start monitoring the selected port. SETTINGS To select the proper COM port address to be viewed. SEND ACK To acknowledge each signal one by one. ENABLE ACK To acknowledge all signals Use the CLEAR SCREEN button to clear the display.
MCDI Inc. Internet: http://www.mcdi.com 86 Claude-Champagne Avenue, Montreal, QC, Canada H2V 2X1 Telephone: +514-481-1067 Fax: +514-481-1487
Page 7
Page 7
Installation guide for Alarm Receiver Exprecium
Setting up your Exprecium
There is no switches or jumpers to configure your card. All settings are done using the setup program called XPRECIUM.EXE ( provided on the media coming with your card ). This program works under DOS or Windows and can be executed from any disk drive. To use it under Windows, your Windows drivers must be installed first and properly configured.
To enter in the configuration menu, type XPRECIUM<enter> Under DOS or Windows, double click on the icon XPRECIUM.
The following display will appear :
ADDRESS/IRQ Xprecium Parameters MCDI Inc. +(514) 481 1067
D400 15 Version : 0.0.9 S.A.M.M. Section XXXX yy XXXX yy Receiver number : 1 Keep receiver number : No XXXX yy Line 1 number : 1 Keep line number : No XXXX yy Line 2 number : 2 Offset : 0 XXXX yy Heartbeat : No Compress Contact ID : No XXXX yy Sescoa SS instead 4x2 sum : No XXXX yy 3x2 instead 4x1 : No XXXX yy Clear zero : No XXXX yy Compress Extended : No XXXX yy Listen In (Empty or 1..F) : XXXX yy Printer / Buzzer : No 1 = 1400Hz / VFSK XXXX yy Start Handshake with : 1 >>> 2 = SIA / CFSK XXXX yy Wait after Off Hook : No 3 = DUAL1400Hz/2300Hz XXXX yy Caller ID to PC : No 4 = 2300 Hz XXXX yy Caller ID to Printer : No 5 = STRATEL Caller ID ALL : No 6 = TELIM Date / Time : YES 7 = ROBOFON Send Year : No ACK Delay : 1 <CR> Edit Sur-gard mode : No <CTRL U> UPDATE
<ESC> Exit <F1> Restore default <F2> Read Config File
Setup program display description and commands
Address / IRQ section
Address part of display shows address fields and IRQ’s setting for all Exprecium receivers installed in PC. Only the cards installed will appear in the list Move cursor to desired Exprecium using Up/Down arrows. Press <Enter> to move to Parameter section on right part of display. Parameters displayed on the right are actual operating parameters. Press F1 to restore Factory defined parameters. Press F2 to restore saved parameters. Press CTRL-U to start the firmware update process. See section FIRMWARE UPGRADE. Press <ESC> to Exit setup program XPRECIUM. Before accepting Exit command, XPRECIUM utility request authorization to save new parameters.
Note : When exiting from XPRECIUM setup program, real time clock on ALL Exprecium will be reset to PC time.
MCDI Inc. Internet: http://www.mcdi.com 86 Claude-Champagne Avenue, Montreal, QC, Canada H2V 2X1 Telephone: +514-481-1067 Fax: +514-481-1487
Page 8
Installation guide for Alarm Receiver Exprecium
Parameter section to the right of Address section
Move cursor to desired parameter using UP/DN arrow. Key in each new parameter . After all changes have been entered press <ESC> to go back to Address Section. ONLY in Address Section can changes be saved and sent to receiver.
Parameter definition
Emulation mode easy setting information: MCDI Mode Default setting
Ademco 685 Mode Default setting + Date / Time = NO Surgard Mode Surgard = YES
OPTIONS: ( default settings are indicated in bold ) Receiver Number sent to computer and printer 0 to F 1 Line 1 Number sent to computer and printer 0 to F 1 Line 2 Number sent to computer and printer 0 to F 2 Heartbeat Yes = enable No = disable
Heartbeat signals are sent to computer every 30 seconds only in MCDI and Surgard mode.
Sescoa SS Yes = enable No = disable
Conflict with Pulse 4X2 Checksum format
3x2 Instead 4x1 Yes = enable No = disable
Conflict with 4X1 in Compressed Expanded DO NOT select with Compressed Expanded = YES
Page 8
Clear Zero Yes = Zero removed in 3x1 and 4x1 No = zero present
Tells the receiver not to insert a zero in front of the account number and in front of the alarm code, for incoming 3 x 1 and 4 x 1.
Example: 3 x 1 Extended compressed in 3 x 2 standard
Example: 3 x 1 Standard 3 x 1
Example: 4 x 1 Standard 4 x 1
Example: 3 x 1 and 4 x 1 without the CLEAR ZERO option:
Compressed/ Yes = Compressed extended 3x1 or 4x1 No = default Extended
Example:3 x 1 Extended compressed in 4 x 2 standard
123 4 444 5 After compression: 0123 45
Example:4 x 1 Extended compressed in 4 x 2 standard
1234 5
5555 6After compression: 1234 56
Listen-In Empty or 1 .. F Empty (3x1,4x2) Define code to trigger Listen-In mode in 3x1 or 4x2 formats
Printer/Buzzer Yes = Check printer on Exprecium port No= Do not check for printer
MCDI Inc. Internet: http://www.mcdi.com 86 Claude-Champagne Avenue, Montreal, QC, Canada H2V 2X1 Telephone: +514-481-1067 Fax: +514-481-1487
123 4 444 5 After compression: 123 45
123 1
1234 1
0123 01 for 3 x 1 1234 01 for 4 x 1
Page 9
Installation guide for Alarm Receiver Exprecium
By default the Exprecium does not verify printer status on parallel port but sends data to be printed as if a printer was connected to this port.
(Yes) option tells the Exprecium receiver to verify and report on the status of the printer connected to its parallel port. A connector is supplied to daisy chain multiple receiver cards ( Exprecium, TLR+ or TLR ) in the same computer to send all output to one printer only.
When Check printer option is enabled (Yes) and the computer is absent, each event being sent to printer triggers a warning buzzer. This warning sound may be stopped by clicking twice the ON-LINE printer key. Buzzing resumes if printer is left Off-line.
Do not set the "Yes" parameter if no printer is installed. Multiple error messages could be generated by taking this action.
Start handshake with 1 1400hz / VFSK
2 SIA / CFSK 3 DUAL 1400hz / 2300hz 4 2300hz 5 STRATEL 6 TELIM 7 ROBOFON
Default sequence is as above. Option is to change first element with the one selected. Extreme care must be exercised when changing Handshake sequence. It is a well known fact that
many dialers do not respond well to all startup sequences. Wait after O/H Delay to start Handshake after Off Hook. No = normal, Yes=5 seconds Caller ID PC No = Do not send telephone ID data to PC
Yes = Send telephone ID data to PC Caller ID PRN No = Do not send telephone ID data to the Exprecium printer port
Yes = Send telephone ID data to the Exprecium printer port Caller ID ALL No = Do not send telephone ID data except when bad transmission occurs
Yes = Send telephone ID data to PC and Exprecium printer port unless PRN and PC select otherwise Date / Time Yes = enable No = disable Send year Yes = Date including the year No = Date with out year
Yes, tells the Exprecium to add the Year in date format: HH:mm _ _ MM/DD[/YY] ...
No,tells the Exprecium to use date and time format: MM/DD. ACK delay Wait time in seconds for ACK reception before resend. (Surgard/Native mode only)
1 to 9 1= default Surgard Mode Yes = enable No = disable
Page 9
SAMM Automation software Section Keep receiver number No = default YES = Insert receiver # in front of account #
Keep line number No = default YES = Inset line # in front of account #
Offset 0 (zero) = default Insert digit 0 to 9 or letter A to F in front of account #
Compress Contact ID No = default YES = Use Compress Contact ID instead of standard one
Connectors, leds and Jumpers - Main board
J1 External battery connector 6 - 12 votls J2 Connector port for IBM compatible parallel printer type DB25. When more than one card is installed in the same computer,
J3 PCI bus connector JP1 Future use
MCDI Inc. Internet: http://www.mcdi.com 86 Claude-Champagne Avenue, Montreal, QC, Canada H2V 2X1 Telephone: +514-481-1067 Fax: +514-481-1487
one printer can be used for all cards in the same computer, instead of one printer per receiver card. See TX1,RX1 below.
Page 10
Page 10
Installation guide for Alarm Receiver Exprecium
JP2,7,9 Connectors to receive Communication Interface Module JP3 Line 1 Phone connector type RJ11. Connect Green and Red only on each connector JP4 Connector for external leds (future use) JP5 Processor jumper pin 2-3 (do not remove) JP6 Line 2 Phone connector type RJ11. Connect Green and Red only on each connector JP8 Dry contacts relay (furure use) JP10 Serial communication or MRD1000 Remote Display. TX1, RX1 Connectors for chaining more than one Exprecium card. This allows only one external printer to serve all receiver cards.
PWR1 For MRD1000 remote display power feed. S1 Reset switch for the receiver. Two options are available.
D1 & D2 Both leds are ON to indicate power from the PC. Only Led D2 is ON when PC is OFF and the Exprecium is powered by
Connectors - Communication Interface Module
JP1,2,3 Connectors to connect to the Main Board
When more than one receiver card is installed, use a jumper to link all receiver cards. Connect TX1 of the first card to RX1 of the second card. Connect your printer on the last card having only a jumper on RX1.
1. Soft Reset: Press once to reset the receiver to the user’s configuration.
2. Cold Reset: Press once and wait for beep. During the beep press once more. Soft and Cold Reset can also be software achieved by running XPRECIUM setup program as shown in Setting up your
Exprecium .
an external source on J1.
Physical characteristics of the Exprecium
Size : Receiver has all out dimensions, including bracket of 20.3x12.7
Buffer memory : Buffer holds up to 1800 events in a non volatile memory. Buffer is
cm or 5x8 inches.
used only when computer is absent. Card keeps printing during fail time if 6 volt external battery is
connected and charged. When computer comes back on, buffer empties to the computer. If more than 1800 events are received in the buffer during fail time, card writes over the oldest event. Written records may be available on printer connected to parallel printer port.
External battery connectorr
A six (6) volt battery connector is designed to feed receiver if computer fails. A 3 foot wire is supplied. Connect the red wire to the positive side and the black wire to the negative side of the battery.
During normal operation, card takes its power from computer and maintains battery charge. When computer fails, card takes its power from battery and keeps on receiving alarms.
Battery size (power) is dependent on the period it must maintain the receiver operating while PC is off. As a rule of the thumb, define the number of hours a fully charged battery must support the system and divide by two (2) to get the A-H.
Example: To support the receiver for 8 hours requires a 4 A-H rechargeable battery.
Battery type recommended: Rechargeable sealed lead-acid for constant voltage.
Buzzer Alert/Warning
On board buzzer is available for alert warning when Computer is absent. Enable if setup parameter Check printer is set to Yes. Is activated (start buzzing) by event to be printed on the Exprecium printer port. Stop buzzing by pressing twice (2) ON-LINE printer key. Refer to printer connected to the Exprecium parallel printer port. Will resume buzzing if printer is left off-line.
MCDI Inc. Internet: http://www.mcdi.com 86 Claude-Champagne Avenue, Montreal, QC, Canada H2V 2X1 Telephone: +514-481-1067 Fax: +514-481-1487
Page 11
Page 11
Installation guide for Alarm Receiver Exprecium
Formats and characters transmitted
Receiving Formats MCDI DTMF FSK
Acron Ademco Contact ID Ademco L/S Standard Ademco L/S expanded Ademco Fast / High Speed Ademco Express Ademco Old DCI FBI Super Fast Franklin Fast Napco Radionics Standard Radionics Expanded Scantronic Sescoa standard Sescoa SS SIA I - II - ~III Silent Knight Slow/Fast CFSK III Varitech VFSK Stratel SurGard Robofon Telim
Pulse 10,20,40 bps 3x1 - 4x1 - 4x2 Dual Round
10,20,40 bps 4x2 Checksum 10,20,40 bps 3x1 - 4x1 Extended Dual Round Frequencies 1800 Hz / 1900 Hz
Handshake and kissoff: 1400hz / 2300hz DTMF 10 char/sec. FSK 110 bauds or 300 bauds (SIA, CFSK, VFSK) Bell 103 Listen-in, Two way voice
Listen-in function Some alarm panels offer the option for the Central station operator to listen for sound in the premises where the alarm signal originates. Alarm panels supporting “Listen-in” keep the telephone line open after having sent a signal, to allow sound monitoring. The telephone
line will be closed by the Central station subject to operator action or receiver setup. Listen-in criteria The Exprecium receiver is triggered into “Listen-in” mode for incoming events according to panel setup for specific formats. SIA and Contact ID formats have specific codes for Listen-in. See Panel setup. DTMF formats use the AEx signal where x can be 0 to F at the Installer’s choice. 3x1 and 4x2 formats have no standard codes for Listen-in. Exprecium allows home selection of Listen-in codes at Setup time. Receiver action upon reception of “Listen-in” trigger Upon reception of event in the Listen-in category, the receiver maintains the telephone line open for a period of up to 180 seconds or
less then 180 seconds upon reception of any telephone tone from the keypad. Operator control for “Listen-in” Operator must be warned by Monitoring software of account “listen-in” capability. Operator has a maximum of 180 seconds from time
of alarm reception to telephone pickup. Failure to pickup telephone in this delays will cause line hang-up by the receiver. Once the line is seized by Central station local telephone, the hang-up action of the receiver will have no effect. To close communication with alarm signal site in the first 180 seconds when the Exprecium receiver is in action, operator must press
any key on the telephone keypad before hanging up. The receiver will hang up before 180 seconds only upon reception of a tone from telephone keypad.
To close communication with alarm signal site after 180 seconds of event reception, simply hang-up the telephone. This is because the Exprecium receiver is not in function anymore, its delay having expired.
Transmission to computer and printer in EXPRECIUM MCDI mode Pulse, DTMF, FSK
FORMAT 3x1, 4x1
HH:mm_ _MM/DD[/YY] _ _ RL_CCCC_ØA<CR> Default HH:mm_ _MM/DD[/YY] _ _ RL_CCCC_A<CR> Option 4x1 set by INITLR
MCDI Inc. Internet: http://www.mcdi.com 86 Claude-Champagne Avenue, Montreal, QC, Canada H2V 2X1 Telephone: +514-481-1067 Fax: +514-481-1487
Page 12
Installation guide for Alarm Receiver Exprecium
HH:mm_ _MM/DD[/YY] _ _ RL_CCC_A<CR> Option 3x1 set by INITLR HH:mm_ _MM/DD[/YY] _ _ RL_ØCCC_AZ<CR> Option 3x1 extended compressed 4x2 HH:mm_ _MM/DD[/YY] _ _ RL_CCCC_AZ<CR> Option 4x1 extended compressed 4x2
Option zero removed 3x1,4x1, extended
FORMAT 4x2
HH:mm_ _MM/DD[/YY] _ _RL_CCCC_AZ<CR>
FORMAT 4x3 (SESCOA SS)
HH:mm_ _MM/DD[/YY] _ _RL_CCCC_AZZ[Z]<CR>
FORMAT 4x3 (SUR GARD)
HH:mm_ _MM/DD[/YY] _ _RL_CCCC_AZZ<CR>
FORMAT ADEMCO HIGH SPEED
HH:mm_ _MM/DD[/YY] _ _RL_CCCC_AAAA_AAAA_A<CR>
FORMAT ACRON
HH:mm_ _MM/DD[/YY] _ _RL_CCCC_AAAAAAAA<CR> HH:mm_ _MM/DD[/YY] _ _RL_ _CCC_AAAAAAAA<CR>
FORMAT FBI SUPER FAST
HH:mm_ _MM/DD[/YY] _ _RL_CCCC_E ZZ<CR>
FORMAT CONTACT ID
HH:mm_ _MM/DD[/YY] _ _RL_CCCC_18_TAAA_GG_ZZZ<CR>
FORMAT MODEM SIA
HH:mm_ _MM/DD{YY}] _ _RL _ [#CCCCCC|EAAZZZ/AAZZZ/AAZZZ]<CR> Native mode <LF>RL_ [#CCCCCC|EAAZZZ/AAZZZ/AAZZZ]<CR> Ademco685 Emulation
FORMAT MODEM CFSK / VFSK (same as 4x2)
HH:mm_ _MM/DD{/YY} _ _ RL_CCCC_AZ<CR>
CALLER ID
Phone signal added to event code. Examples HH:mm_ _MM/DD[/YY] _ _RL_CCCC_AZ{t...t}<CR> Added to 4x2
HH:mm_ _MM/DD[/YY] _ _RL_CCCC_18_TAAA_GG_ZZZ {t...t}<CR> Added to Contact ID HH:mm_ _MM/DD{YY}] _ _RL _ [#CCCCCC|EAAZZZ/AAZZZ/AAZZZ]{t...t}<CR> Added to SIA
Heartbeat
@<CR> Signal sent to the computer every 30 seconds if option is enabled
Page 12
Code definitions
HH : Hour : : Character ":" mm : Minute DD : Day _ : 1 space _ _ : 2 spaces MM : Month [YY] : Year [Present/Absent] Receiver Option) / : Character "/" R : Receiver number (Receiver Option) L : Line number (Receiver Option) C : Account number A : Event code or modifier E : Zone type FBI super Fast Z : Zone G : Group (Partition)
MCDI Inc. Internet: http://www.mcdi.com 86 Claude-Champagne Avenue, Montreal, QC, Canada H2V 2X1 Telephone: +514-481-1067 Fax: +514-481-1487
Page 13
Installation guide for Alarm Receiver Exprecium
T : Type(E or R) (Contact ID) Ø : Zero <CR> : EOS (Carriage Return) <ACK> : Data retransmits to computer every 2 second until ACK is received (ACK=06H or $06). @ : Heartbeat signal Receiver Option) t...t : Telephone number from Caller ID [ : Beginning data delimiter (SIA) ] : Ending data delimiter (SIA) | : Field separator (SIA) # : Account ID block code (SIA) E : Function block code (SIA) / : Data code packet separator (SIA) <LF> : Line Feed
EXPRECIUM Error and Warning messages sent to Printer port and PC:
HH:MM MM/DD[YY] RL
Account XYY
Page 13
Printer message Time Date Receiver account 01 Printer error
Time Date Receiver account 02 Printer reset
Telephone line monitoring Time Date Receiver account 03 Error Line 1
Time Date Receiver account 04 Reset Line 1
Telephone line monitoring Time Date Receiver account 05 Error Line2
Time Date Receiver account 06 Reset Line2
External battery backup Time Date Receiver account 07 Low external battery
Time Date Receiver account 08 Normal external battery
Transmission message Time Date Receiver 0000 00 Bad transmission
Time Date Receiver [#0000|A BAD TRANSMISSION]Format SIA
No Transmission Time Date Receiver 0000 F1 No signal received Line 1
Time Date Receiver 0000 F2 No signal received Line 2
Transmission to computer and printer in ADEMCO 685 / Surgard emulation mode
User Manual : for information on transmission See ADEMCO 685 standards User Manual : for information on transmission See Surgard MRL2 documentation
Surgard emulation applies to Dial up Alarm signals and Telephone ID
Messages from EXPRECIUM printer port:
When computer ceases to communicate, "Computer absent" message is sent to the Exprecium printer port When computer resumes communication, "Computer restore" message is sent to to the Exprecium printer port
Transmission rate
1200 bps, no parity, 8 bits, I stop bit
MCDI Inc. Internet: http://www.mcdi.com 86 Claude-Champagne Avenue, Montreal, QC, Canada H2V 2X1 Telephone: +514-481-1067 Fax: +514-481-1487
Page 14
Page 14
Installation guide for Alarm Receiver Exprecium
Warranty
The Electronic products of MCDI Inc. are under a five year limited warranty. Material is repaired or exchanged, free of charge, when
returned to MCDI service points, post paid. Abused or misused equipment is not covered by this warranty. Power surge damages
are not covered by warranty.
Legal compliance and Warning
United States Regulation FCC Warning Radio/TV interference
This device is not equipped with dialing equipment. Telephones equipped with electronic dialing keys generate and use radio frequency energy, and if not installed and used properly and in
strict accordance with the manufacturer's instructions, may cause interference to radio and television reception. NOTE: This device has been tested and found to comply with Part 15 if the FCC rules. Operation is subject to the following two
conditions:
1. This device may not cause harmful interference and
2. This device must accept any interference received, including interference that may cause undesirable operation. If your device causes interference, one of the following measure may correct the problem: . Reorient or relocate the receiving TV or radio antenna, when this may be done safely.
. To the extent possible, move the device and the radio or television farther away from each other, or connect the computer with the
device and the radio or television to outlets on separate circuits.
. Consult the dealer or an experienced radio/television technician for additional suggestions. NOTE: FCC registration does not constitute an expressed or implied guarantee of performance.
Right of the Telephone Company If this device causes harm to the telephone network, the telephone company may stop your service temporarily or ask you to remove your
equipment until the problem is resolved. If possible, they will notify you in advance. If advance notice is not practical, you will be notified as soon as possible and be given the opportunity to correct the situation. You will also be informed of your right to file a complaint with the FCC.
Your telephone company may make changes in its facilities, equipment, operations or procedures that could affect the proper function of this device. If they do, you will be notified in advance to give you an opportunity to maintain uninterrupted telephone service.
Federal communication commission (FCC) Notice FCC Registration Number: This device complies with Part 68, Rules and Regulations, of the FCC for direct connection to the Public
Switched Telephone Network (the FCC registration number and REN number appear on a sticker). If requested, this information must be provided to the telephone company.
Your connection to the telephone line must comply with these FCC rules: . Use only an FCC standard RJ11W/RJ14W or RJ11C/RJ14C network interface jack and FCC compliant line cord and plug to
connect to the telephone line. (To connect the device press the small plastic tab on the plug at the end of the telephone's line cord. Insert into a jack until it clicks. To disconnect, press the tab and pull out.)
. If a network interface jack is not already installed in your location, you can order one from your telephone company. Order
RJ11W/RJ14W for wall mounted telephones or RJ11C/RJ14C for desk/table use. In some states, customers are permitted to install their own jacks.
. This device may not be connected to a party line or coin telephone line. Connection to Party Line Service is subject to state tariffs
(contact the state public utility commission, public service commission or corporation commission for information).
. It is no longer necessary to notify the telephone company of your device's Registration and REN number however, you must provide
this information to the telephone company if they request it.
. If trouble is experienced with this equipment, for repair or warranty information please contact:
Local dealer or MCDI 86 Claude-Champagne Avenue., Montreal, QC, Canada H2V 2X1 Telephone: +(514) 481-1067 Fax: +(514) 481-1487
MCDI Inc. Internet: http://www.mcdi.com 86 Claude-Champagne Avenue, Montreal, QC, Canada H2V 2X1 Telephone: +514-481-1067 Fax: +514-481-1487
Page 15
Page 15
Installation guide for Alarm Receiver Exprecium
. If the equipment is causing harm to the telephone network, the telephone company may request that you disconnect it until the
problem is resolved.
. This device does not have any serviceable parts. Repair or exchange must be made by the manufacturer or its representatives. Signaling method: This device does not dial out. Ringer Equivalence Number: The FCC Registration label (on the device) includes a Ringer Equivalence Number (REN) which is used
to determine the number of devices you may connect to your telephone line. A high total REN may prevent telephones from ringing in response to an incoming call and may make placing calls difficult. In most areas, a total REN of 5 should permit normal telephone operation. To determine the total REN allowed on your telephone line, consult your local telephone company.
Hearing aids This device does not convert the signal for human hearing. Programming Emergency numbers: This device does not dial out. Important safety instructions When using the device, basic safety precautions should always be followed to reduce risk of fire, electrical shock and injury to persons
including the following:
1. Read and understand all instructions.
2. Follow the warnings and instructions marked on the product.
3. This device is installed in a computer. This work should be done by a qualified computer technician.
4. Avoid using during electrical storm. There may be a remote risk of electrical shock from lightning.
5. CAUTION: Do no use sharp instruments during installation procedure to eliminate the possibility of accidental damage to the
device, the computer or the cord.
6. Save these instructions.
Europe EC Declaration of Conformity We:
MCDI Inc. 86 Claude-Champagne Avenue Montreal, QC Canada H2V 2X1
Declare under our sole legal responsibility that the following products conform to the protection requirements of council directive 89/336/EEC on the approximation of the laws of member states relating to electromagnetic compatibility, as amended by directive 93/68/EEC:
MCDI-EXPRECIUM alarm receiver
The products to which this declaration relates are in conformity with the following relevant harmonised standards, the reference numbers of which have been published in the Official Journal of the European Communities:
EN50082-1:1992 --- EN55022 CLASS A --- EN 60555 PARTS 2 & 3 ---EN41003:1993 --- BAPT Note 48 revision 5
EN60950/IEC Ed 2 Amendment No1 1992, Amendment No2 1993, Amendment No3 1996
MCDI Inc. Europe EN41003 Warning Application Note 48, Issue 5
1) The power required by the host and the total of all adapter cards installed within the host environment, together with any auxiliary
apparatus, shall not exceed the power specification of the host apparatus. The power requirements for the EXPRECIUM receiver are:
From computer 12V 200 mA max. From External Battery (standby) 6V 500 mA Charging Voltage 6.7 Volts 500 mA (Current Limit)
2) It is essential that, when other option cards are introduced which use or generate a hazardous voltage, the minimum creepages and clearances specified in the table below are maintained. A hazardous voltage is one which exceeds 42.4V peak a.c. or 60V d.c. If you have any doubt, seek advice from a competent engineer before installing other adapters into the host equipment.
3) The equipment must be installed such that with the exception of the connections to the host, clearance and creepage distances shown in the table below are maintained between the card and any other assemblies which use or generate a voltage shown in the table below. The larger distance shown in brackets applies where the local environment within the host is subject to conductive pollution or dry non-
MCDI Inc. Internet: http://www.mcdi.com 86 Claude-Champagne Avenue, Montreal, QC, Canada H2V 2X1 Telephone: +514-481-1067 Fax: +514-481-1487
Page 16
Page 16
Installation guide for Alarm Receiver Exprecium
conductive pollution which could become conductive due to condensation. Failure to maintain these minimum distances would invalidate the approval.
4) The analogue telecommunications interface is intended to be connected to telecommunication network voltage (TNV) circuits which may carry dangerous voltages. The telephone cord(s) must be disconnected from the telecommunications system until the card has been installed within a host which provides the necessary protection of the operator. If it is subsequently desired to open the host equipment for any reason, the telephone cord(s) must be disconnected prior to effecting access to any internal parts which may carry telecommunication network voltages.
Table:
Clearance (mm) Creepage (mm) Voltage Used or Generated by
X Y Host or Other Cards
2.0 2.4 (3.8) Up To 50 Vrms or Vdc
2.6 3.0 (4.8) Up To 125 Vrms or Vdc
4.0 5.0 (8.0) Up To 250 Vrms or Vdc
4.0 6.4 (10.0) Up To 300 Vrms or Vdc
For a host or other expansion card fitted in the host, using or generating voltages greater than 300V (rms or dc), advice from a competent telecommunication safety engineer must be obtained before installation or relevant equipment
Host:
TLR or TLR+ or Exprecium card
Power Supply Unit
or other source of excessive voltage
X X
Y
Above 300 Vrms or Vdc
Expansion Card
Y
MCDI Inc. Internet: http://www.mcdi.com 86 Claude-Champagne Avenue, Montreal, QC, Canada H2V 2X1 Telephone: +514-481-1067 Fax: +514-481-1487
Page 17
Technical data sheet for “EXPRECIUM” PCI Twin Line Receiver
Description “EXPRECIUM” is a full format PC-based twin-line alarm
receiver card. EXPRECIUM connects to PCI bus of a PC Computer. Its
small size fits table top IBM PCs or compatible PC Pentium and up. EXPRECIUM interfaces to two telephone lines, imposing no limit to the number of customers per line. It provides a parallel printer port for direct output without going through PC.
With large size memory, fast modem circuit, improved PC bus interface and Caller ID option, EXPRECIUM adds a new dimension to Alarm Receiving and PC integrated Monitoring Station.
All MCDI’s PCB receivers work even if PC is down. If external battery power is provided, naturally.
Option: Remote display / control unit. Packaged as stand alone device or fitted in PC’s CD anchor slot.
Certification
FCC(USA), IC(Canada), CE-Security (Europe), CE-0560 Telecom (Europe)
Specifications
Communications: EXPRECIUM provides 2 RJ11 type jacks for telephone
line connection. Type : Pulse, DTMF, FSK
Reception Speed : 10, 20, 40 pps DR / CS Handshake and Kiss-off : 1400Hz / 2300Hz/2225Hz Pulse Frequency : 1800Hz / 1900Hz Telim//Robofon : 1180Hz / /1100Hz
Reception Formats supported:
Acron Radionics 6500 Ademco: Radionics extended
- Slow/Fast; Sescoa Slow, Super Fast
- Contact ID; Sescoa Standard
- Extended; SIA
- Express; Contact ID
- High Speed - compressed & Extended CFSK,BFSK, VFSK MCDI-Take-a-look SurGard FBI Super Fast Napco Point ID 3x1 3x1 extended 4x1 3x1 extended compressed 4x2 4x1 extended 4x1 extended compressed 4x2 4x2 Zero removed 3x1, 4x1, extended. Optex’s Varitech C&K: Bell 103A2 or CCIT ( option) For Germany and Scandinavia (option):
Telim Robofon
Printer Output:
Standard DB25 connector for Centronics Parallel Interface.
Card linking arrangement allowing one printer to serve all MCDI PCB receivers in one PC.
Event Logging when PC is absent:
EXPRECIUM can store over 1800 events in standby
operation when PC is down.
Silent Knight Slow
Features
Made for PCI bus connection
Easy to install:Plug & play and Hot swap.
Supports SIA, CFSK, BFSK, VFSK, Etc.
Caller Identification (Option)
Internal buffer 1800 Events
Non Volatile Memory
Dead line detection
Up to 12 receivers or more per PC
Alert/Warning buzzer
Supervision of chargeable back-up battery
Selectable Monitoring software interfaces
Listen-in, Two way voice
Remote control and display (option)
Power Requirements:
From computer +12V Supply: 200 mA max. From 6V Battery (standby): 500 mA
Size and weight:
8” / 20.3 cm (L) x 5” / 12.7 cm(H); 0.484 lb / 220 gr
Station Requirements:
IBM™ or Compatible Pentium™ computer and up. Table top size enclosure. PCI bus. DOS or Windows
Printer with Centronics parallel interface and cable with DB25 connector.
PC addressing:
PCI bus. Plug & Play. PC must have Plug & Play BIOS.
Battery Back-up:
EXPRECIUM provides charging and supervision circuitry
for an external 6-Volt battery (not supplied). 12v battery may be used but no charging will occur.
Charging Voltage 6.7 volts Charging Current Limit 500 mA
Monitoring Software:
EXPRECIUM interfaces with Monitoring software in
Native mode, Ademco™ 685 emulation mode and SurGard™ MLR2 emulation mode.
Optional remote control MRD1000:
Displays incoming signals or controls on 2 lines by 20
characters.
Configures and operates EXPRECIUM, TLR+ or SA-
TLR+.
Alarm acknowledge key for easy operation.
Power fed by EXPRECIUM, TLR+ or SA-TLR+.
External self contained unit or Mounted in PC’s CD slot.
MCDI Inc. Internet: http://www.mcdi.com 86 Claude-Champagne Avenue, Montreal, QC, Canada H2V 2X1 PH: +514-481-1067 FX: +514-481-1487