MBT Lighting SRS-7001 User Manual

LEDSMARTSCAN
User Manual
Please read this user manual before using this product.
Features
Voltage: AC120V 60Hz
High performance mobile DMX scanner with 1 x 30W LED source
8 Colors + White
8 Gobos + Spot
Separate Color & Gobo Wheels
8 DMX Channels
3-Button menu system LED Display making it easy to navigate
3 Operational modes: DMX controller, Master/Slave & Sound Active
Built-in lighting programs
Sound Active
Compact & portable design
Manual focusing lens
Gobo Shake effect
Strobe effect in every color
13-degree beam angle
DMX-512 protocol
Fan cooled
Hanging Bracket Included
Advantages of LED-technology: Extremely long life, low power
consumption, minimal heat emission,
Defacto maintenance free with brilliant light radiation
Master/Slave-operation
Function Display
MENU UP DOWN
Set the desired Master-mode for the master device, set the respective
Slave-mode for all slave devices.
Please note: The function G-3- is only meant for service purposes, please
do only use this function if you want to set the unit shortly into standby
mode.
Operation
After you connected the effect to the mains, the LED DMX scanner starts
running, during the reset, the motors are trimmed and the device is ready
for use afterwards.
Stand-Alone operation
In the stand-alone mode, the light can be used without controller. You can
do without a controller as this scanner features a built-in microphone,
which provides automatic sound control.
Master/slave operation
Connect the master and slave-devices and adjust the settings as
described above.
DMX-controlled operation
You can control the projectors individually via your DMX-controller.
Every DMX-controller has a different occupation with different features.
Addressing
The Control board allows you to assign the DMX fixture address, which is
defined as the first channel from which the scanner will respond to the
controller.
Please, be sure that you don’t have any overlapping channels in order to
control, each LED scanner correctly and independently from any other
fixture on the DMX data link.
If two, three or more LED scanner are addressed similarly, the will work
similarly.
For address setting, press the Menu button until the display shows A.001
and set the desired address via the up/down buttons.
Controlling:
After having addressed all LED Scanner, you may now start operating
these via your lighting controller.
Note: after switching on, the LED Scanner will automatically detect
whether DMX512 data is received or not. If the data is received, the
display will show “A.001” with actually set address. If there is no data
received at the DMX-input,. The display will show ”A 001”
The situation can occur if:
1, the 3Pin XLR plug(cable with DMX signal from controller) is not
connected with the input of the LED scanner.
2, the controller is switched or defective, if the cable or connector is
defective or the signal wires are swap in the input controller.
DMX-Protocol
Channel 1-Horizontal movement (Pan)
Push slider up in order to move the mirror horizontally (Pan)
Gradual mirror adjustment from one end of the slider to the other
(0-255,128-center)
The mirror can be stopped at any position you wish.
Channel 2-Vertical movement (Tilt)
Push slider up in order to move the mirror vertically (TILT)
Gradual mirror adjustment from one end of the slider to the other
(0-255,128-center)
The mirror can be stopped at any position you wish.
Channel 3 –COLORS
Value
Feature
0
14
WHITE
15
29
ORAGNGE
30
44
BLUE
45
59
GREEN
60
74
YELLOW
75
89
PINK
90
104
LIGHT BLUE
105
119
LIGHT GREEN
120
127
LIGHT YELLOW
128
255
RAINBOW EFFET SLOW-FAST
Channel 4- Gobos
Value
Feature
0 7 OPEN
8
14
Spin Gobo 1
15
21
Spin Gobo 2
22
28
Spin Gobo 3
29
35
Spin Gobo 4
36
42
Spin Gobo 5
43
49
Spin Gobo 6
50
56
Spin Gobo 7
57
63
Spin Gobo 8
64
70
OPEN SHAKE
71
77
GOBO 1 SHAKE
78
84
GOBO 2 SHAKE
85
91
GOBO 3 SHAKE
92
98
GOBO 4 SHAKE
99
105
GOBO 5 SHAKE
106
112
GOBO 6 SHAKE
113
119
GOBO 7 SHAKE
120
127
GOBO 8 SHAKE
128
255
GOBO WHEEL ROTATION
SLOW-FAST
Channel 5- Shutter/Strobe
Value
Feature
0 7 Blackout
8
15
Shutter open
16
131
Strobing slow-fast
132
139
Shutter open
140
180
Shutter slow open-fast close
181
189
Shutter open
190
231
Shutter fast open-slow close
232
239
Sutter open(235 reset-after
3-5seconds)
240
247
Random strobe
248
255
Shutter open
Channel 6- Dimmer
0
255
Dimmer
Channel 7-Moving head movement
Value
Feature
0 7 No function
8
25
Movement 1
26
43
Movement 2
44
61
Movement 3
62
79
Movement 4
80
97
Movement 5
98
115
Movement 6
116
133
Movement 7
134
151
Movement 8
152
169
Movement 9
170
187
Movement 10
188
205
Movement 11
206
223
Movement 12
224
241
Movement 13
242
255
Movement 14
Channel 8- Movement speed
0
255
Movement speed slow to fast
Cleaning and Maintenance
The operator has to make sure that safety-relating and machine technical
installations are inspected by an expert after every four years in the
course of an acceptance test.
The operator has to make sure that safety-relating and machine technical
installations are inspected by a skilled person once a year.
The following points have to be considered during the inspection:
1, All screws used for installing the devices or parts of device have to be
tightly connected and must not be corroded.
2. There must not be any deformations on housings, fixations and
installation spots (ceiling, suspension, trussing)
3, Mechanically moved parts like axles, eyes, and others must not show
any traces of wearing(e.g. material abrading or damages) and must not
rotate with unbalances.
4, The electric power supply cables must not show any damages,
material fatigue (e.g. porous cables) or sediments. Further instructions
depending on the installation spot and usage have to be adhered by a
skilled installer and any safety problems have to be removed.
We recommend a frequent cleaning of the device. Please use a moist,
lint-free cloth. Never use alcohol or solvents.
The objective lens will require weekly cleaning as smoke liquid tends to
building up residues, reducing the light output very quickly.
Technical Specifications
Power supply
AC120V, 60Hz
Power consumption
50W
DMX channel
8
DMX 512 connection
3-pin XLR
Sound-control
Via built in mic
Flash rate
18Hz
Number of LED
1*30W white Led
Dimensions (L*W*H)
Weight
Max ambient temperature Ta
45
Max housing temperature Tb (steady state)
55
Min. distance from flammable surfaces
0.5m
Min. distance to lighted object
0.1m
Fuse
F2A,125V
Please note: information is subject to change without prior notice
Loading...