Maytag Services AMV4204AAB, AMV4204AAQ, MMV4205AAB, AMV4204AAW, MMV4205AAW Technical Information

...
Domestic MicrowaveTechnical Information
Over-The-Range Convection Microwave Models AMV4204AAB/W/Q MMV4205AAB/W/Q/S
Due to possibility of personal injury or property damage, always contact an authorized technician for servicing or repair of this unit.
CAUTION
!
All safety information must be followed as provided in Service Manual 16023056.
!
To avoid risk of electrical shock, personal injury or death; disconnect power to oven before servicing, unless testing requires power.
Power Source AMV4204AA* MMV4205AA*
Voltage AC 120 VAC 120 VAC
Amperage 20 A 20 A
Frequency 60 Hz 60 Hz
Single Phase, 3 wire grounded Yes Yes
Power Output
Nominal microwave energy (IEC705) 1150 Watts 1150 Watts
Operating frequency 2450 MHz 2450 MHz
Power Consumption
Microwave, lamp and vent fan 1700 Watts 1700 Watts
Dimensions, Exterior (Cabinet)
Width 29 15/16" 76 cm 29 15/16" 76 cm
Height 16 7/16" 42 cm 16 7/16" 42 cm
WARNING
Depth 15 3/8" 39 cm 15 3/8" 39 cm
Dimensions, Interior (Cavity)
Width 23 1/2" 60 cm 23 1/2" 60 cm
Height 10 3/16 " 26 cm 10 3/16 " 26 cm
Depth 14 1/2" 37 cm 14 1/2" 37 cm
Weight (approx.)
Uncrated 60 lbs 28 kg 60 lbs 28 kg
Crated 68 lbs 30 kg 68 lbs 30 kg
June 2005 16026270
©2005 Maytag Services
1
Component Testing Procedures
!
WARNING
To avoid risk of electrical shock, personal injury or death; disconnect power to oven before servicing, unless testing requires power.
Illustration Component Test Procedure Results
High voltage transformer
120 V
Primary
0 V
Magnetron
High Voltage Capacitor
High Voltage Diode
Secondary
Filament
Relay 7
Discharge Capacitor Disconnect connector and measure continuity with meter on R x 1 scale:
Secondary ......................................
Filament..........................................
Primary (High & Low)......................
(Measure at room temperature, or 70° F/ 22°C) Measure continuity with meter on “High”
scale: Primary winding to ground ..............
Filament winding to ground .............
Discharge Capacitor
Remove wires from magnetron and connect ohmmeter to terminals. Also check between each terminal and ground.
Discharge Capacitor Remove wires from capacitor terminals and connect ohmmeter, set on highest resistance scale to terminals.
Also check between each terminal and capacitor case. Discharge Capacitor
Remove diode lead from capacitor and connect ohmmeter.
Reverse leads for second test. Disconnect the leads. Place water in the oven and select power levels 1 through
10. Check continuity between the terminals of the relays.
Approximately 50-120 Less than 1 Less than 1
Infinite Infinite
Between Terminals: Less than 1 Each terminal to ground: Infinite
resistance. Note: This test is not conclusive. If oven does not heat and all other components test good replace the magnetron and retest.
Between Terminals: Meter should momentarily indicate several ohms, then return to infinity. If no deflection occurs, or if continuous deflection occurs, replace capacitor. Terminal to Case: Infinite resistance
Infinite resistance should be measured in one direction and continuity in the opposite direction. NOTE: Ohmmeter must contain a battery of 6 volts minimum.
Power Level
1 4 sec 18 sec 2 6 sec 16 sec 3 8 sec 14 sec 4 10 sec 12 sec 5 12 sec 10 sec 6 14 sec 8 sec 7 16 sec 6 sec 8 18 sec 4 sec 9 20 sec 2 sec
10 22 sec 0 sec
Cycle On
(Continuity)
Cycle Off
(Open)
16026270 June 2005
©2005 Maytag Services
2
Component Testing Procedures
!
WARNING
To avoid risk of electrical shock, personal injury or death; disconnect power to oven before servicing, unless testing requires power.
Illustration Component Test Procedure Results
Primary Interlock Switch Test (Top Switch)
Measure resistance between terminals 1 and 2:
Door Open...................................................
1
Door Closed.................................................
Open Continuity
2
Secondary Interlock Switch Test (Bottom Switch)
Measure resistance between terminals 1 and 2:
Door Open...................................................
Door Closed.................................................
Open Continuity
Interlock Monitor Switch Test (Middle Switch)
Magnetron Thermal Cut-Out (Thermostat)
Oven Thermal Cut­Out (Thermostat)
Lamp receptacle Test continuity of receptacle terminals......... Indicates continuity if bulb is good and
1
2
Measure resistance between terminals 1 and 2:
Door Open...................................................
Door Closed.................................................
Disconnect all wires from TCO. Measure resistance across terminals.
Magnetron TCO ...........................................
Disconnect all wires from TCO. Measure resistance across terminals.
Oven TCO....................................................
Continuity Open
Open at 302°F (150°C) and closed at 32°F (0°C)
Open at 230°F (110°C) Closed at 0°F (32°C)
installed.
Turntable Drive Motor (Synchronous motor)
A
B
C
Fan motor Remove all wires from motor.
Ventilation Motor Remove all wires
Refer to Parts Manual for proper power cord part number.
Thermistor Remove connector from circuit board.
Power cord Measure resistance of wires ........................ Continuity on each wire.
June 2005 16026270
©2005 Maytag Services
Measure voltage across terminals ...............
Measure resistance across terminals...........
Measure resistance .....................................
Measure resistance across terminals...........
Measure resistance across pins 1 & 3.........
3
Approximately 120 VAC
Approximately 2-4
(All measurements approximate) Across terminals A & C: 35-50 Across terminals A & B: 5-15
Infinite or several, motor is defective.
High Speed: Approximately 49-69 Low Speed: Approximately 97-117
Approximately 250-360 K (70°F, 20°C ± 35°F, 2°C)
Verify polarity and grounding.