Maytag W10150638A, W10150639A User Manual

GAS DRYER
USE & CARE GUIDE
SÉCHEUSE À GAZ
GUIDE D’UTILISATION ET D’ENTRETIEN
FOR QUESTIONS ABOUT FEATURES, OPERATION/PERFORMANCE, PARTS, ACCESSORIES OR SERVICE
CALL: 1.800.688.9900
IN CANADA, CALL: 1.800.807.6777
IN CANADA, WWW.MAYTAG.CA
PARA OBTENER ACCESO AL MANUAL DE USO Y CUIDADO EN ESPAÑOL, O PARA OBTENER INFORMACIÓN ADICIONAL ACERCA DE SU PRODUCTO, VISITE: WWW.MAYTAG.COM.
TENGA LISTO SU NÚMERO DE MODELO COMPLETO. PUEDE ENCONTRAR EL NÚMERO DE MODELO Y DE SERIE DENTRO DE LA CAVIDAD SUPERIOR DE LA PUERTA.
W10150638A
AU CANADA, POUR ASSISTANCE, INSTALLATION OU SERVICE, COMPOSEZ LE : 1.800.807.6777
OU VISITEZ NOTRE SITE INTERNET À
WWW.MAYTAG.CA
TABLE OF CONTENTS
DRYER SAFETY........................................................................................................................ 3
INSTALLATION INSTRUCTIONS ........................................................................................... 5
Tools and Parts..................................................................................................................... 5
Optional Pedestal................................................................................................................. 5
Location Requirements......................................................................................................... 6
Electrical Requirements........................................................................................................ 8
Gas Supply Requirements .................................................................................................... 9
Venting Requirements........................................................................................................10
Plan Vent System................................................................................................................11
Install Vent System .............................................................................................................13
Install Leveling Legs ...........................................................................................................13
Make Gas Connection........................................................................................................ 13
Connect Vent ..................................................................................................................... 14
Level Dryer ........................................................................................................................14
Reverse Door Swing........................................................................................................... 14
Complete Installation ......................................................................................................... 16
DRYER USE............................................................................................................................ 17
Starting Your Dryer.............................................................................................................18
Stopping Your Dryer .......................................................................................................... 19
Pausing or Restarting.......................................................................................................... 19
Control Locked................................................................................................................... 19
Drying and Cycle Tips........................................................................................................ 19
Status Lights........................................................................................................................ 19
Cycles ................................................................................................................................ 20
Additional Features ............................................................................................................ 21
Drying Rack ....................................................................................................................... 21
DYER CARE ........................................................................................................................... 22
Cleaning the Dryer Location .............................................................................................. 22
Cleaning the Lint Screen .................................................................................................... 22
Cleaning the Dryer Interior................................................................................................. 23
Removing Accumulated Lint.............................................................................................. 23
Vacation and Moving Care ................................................................................................ 23
Changing the Drum Light................................................................................................... 23
TROUBLESHOOTING...........................................................................................................24
ASSISTANCE OR SERVICE..................................................................................................... 26
ACCESSORIES .......................................................................................................................26
WARRANTY .......................................................................................................................... 27
TABLE DES MATIÈRES
SÉCURITÉ DE LA SÉCHEUSE................................................................................................. 29
INSTRUCTIONS D’INSTALLATION ..................................................................................... 31
Outillage et pièces .............................................................................................................31
Piédestal facultatif .............................................................................................................. 31
Exigences d’emplacement.................................................................................................. 32
Spécifications électriques...................................................................................................34
Spécifications de l'alimentation en gaz .............................................................................. 35
Exigences concernant l'évacuation ....................................................................................36
Planification du système d’évacuation ...............................................................................38
Installation du système d’évacuation..................................................................................39
Installation des pieds de nivellement.................................................................................. 39
Raccordement au gaz......................................................................................................... 40
Raccordement du conduit d’évacuation............................................................................. 41
Mise à niveau de la sécheuse............................................................................................. 41
Inversion du sens d'ouverture de la porte........................................................................... 41
Achever l’installation..........................................................................................................43
UTILISATION DE LA SÉCHEUSE...........................................................................................44
Mise en marche de la sécheuse.......................................................................................... 44
Arrêt de la sécheuse ...........................................................................................................45
Pause ou remise en marche................................................................................................45
Verrouillage des commandes............................................................................................. 46
Conseils pour le séchage et les programmes ...................................................................... 46
Témoins lumineux..............................................................................................................46
Programmes ....................................................................................................................... 47
Caractéristiques supplémentaires .......................................................................................48
Grille de séchage ...............................................................................................................49
ENTRETIEN DE LA SÉCHEUSE .............................................................................................. 50
Nettoyage de l'emplacement de la sécheuse...................................................................... 50
Nettoyage du filtre à charpie.............................................................................................. 50
Nettoyage de l’intérieur de la sécheuse.............................................................................. 51
Retrait de la charpie accumulée.........................................................................................51
Précautions à prendre pour les vacances et avant un déménagement ................................51
Changement de l’ampoule d’éclairage du tambour............................................................51
DÉPANNAGE ........................................................................................................................52
ASSISTANCE OU SERVICE.................................................................................................... 54
ACCESSOIRES........................................................................................................................ 54
GARANTIE............................................................................................................................. 55
2
DRYER SAFETY
Your safety and the safety of others are very important.
We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety messages.
This is the safety alert symbol. This symbol alerts you to potential hazards that can kill or hurt you and others. All safety messages will follow the safety alert symbol and either the word “DANGER” or “WARNING.”
These words mean:
You can be killed or seriously injured if you don't immediately
DANGER
WARNING
All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you what can happen if the instructions are not followed.
WARNING: For your safety, the information in this manual must be followed to minimize the risk of fire or explosion, or to prevent property damage, personal injury, or death.
follow instructions.
can be killed or seriously injured if you don't
You instructions.
follow
Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this
or any other appliance.
WHAT TO DO IF YOU SMELL GAS:
Do not try to light any appliance.
Do not touch any electrical switch; do not use any phone in your building.
Clear the room, building, or area of all occupants.
Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's
instructions. If you cannot reach your gas supplier, call the fire department.
Installation and service must be performed by a qualified installer, service agency, or
the gas supplier.
3
In the State of Massachusetts, the following installation instructions apply:
Installations and repairs must be performed by a qualified or licensed contractor, plumber, or gasfitter qualified or licensed by
the State of Massachusetts.
If using a ball valve, it shall be a T-handle type.
A flexible gas connector, when used, must not exceed 3 feet.
IMPORTANT SAFETY INSTRUCTIONS
WARNING:
including the following:
Read all instructions before using the dryer.
Do not place items exposed to cooking oils in your dryer. Items contaminated with cooking oils may contribute to a chemical reaction that could cause a load to catch fire.
Do not dry articles that have been previously cleaned in, washed in, soaked in, or spotted with gasoline, dry­cleaning solvents, or other flammable or explosive substances as they give off vapors that could ignite or explode.
Do not allow children to play on or in the dryer. Close supervision of children is necessary when the dryer is used near children.
Before the dryer is removed from service or discarded, remove the door to the drying compartment.
Do not reach into the dryer if the drum is moving.
Do not install or store the dryer where it will be exposed to the weather.
Do not tamper with controls.
To reduce the risk of fire, electric shock, or injury to persons when using the dryer, follow basic precautions,
Do not repair or replace any part of the dryer or attempt any servicing unless specifically recommended in this Use and Care Guide or in published user-repair instructions that you understand and have the skills to carry out.
Do not use fabric softeners or products to eliminate static unless recommended by the manufacturer of the fabric softener or product.
Do not use heat to dry articles containing foam rubber or similarly textured rubber-like materials.
Clean lint screen before or after each load.
Keep area around the exhaust opening and adjacent surrounding areas free from the accumulation of lint, dust, and dirt.
The interior of the dryer and exhaust vent should be cleaned periodically by qualified service personnel.
See installation instructions for grounding requirements.
SAVE THESE INSTRUCTIONS
IMPORTANT: The gas installation must conform with local codes, or in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1/NFPA 54 or the Canadian Natural Gas and Propane Installation Code, CSA B149.1.
The dryer must be electrically grounded in accordance with local codes, or in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70 or Canadian Electrical Code, CSA C22.1.
4
INSTALLATION INSTRUCTIONS
Tools and Parts
Gather the required tools and parts before starting installation. Read and follow the instructions provided with any tools listed here.
8" or 10" pipe wrench
8" or 10" adjustable wrench (for gas
connections)
Flat-blade screwdriver
Adjustable wrench that opens to 1"
(2.5 cm) or hex-head socket wrench (for adjusting dryer feet)
¹⁄₄" nut driver or socket wrench
(recommended)
Parts supplied
Remove parts packages from dryer drum. Check that all parts are included.
4 Leveling legs
NOTE: Do not use leveling legs if installing the dryer on a pedestal.
Parts needed
Check local codes and with gas supplier. Check existing gas supply, electrical supply and venting. Read “Electrical Requirements,” “Gas Supply Requirements” and “Venting Requirements” before purchasing parts.
For close-clearance installations between 31.5" (80.01 cm) and 37" (93.98 cm), see “Plan
Vent System” section for venting requirements.
Level
Knife
Vent clamps
Pipe-joint compound resistant to LP gas
Caulking gun and compound (for
installing new exhaust vent)
Pliers
Tape measure
Optional Pedestal
Are you placing the dryer on a pedestal? You have the option of purchasing pedestals of different heights separately for this dryer. You may select a 10" (25.4 cm) pedestal or a
15.5" (39.4 cm) pedestal with a storage drawer. The pedestal will add to the total height of the dryer for a total height of approximately 46" (116.8 cm) or 51.5" (130.8 cm), respectively.
For a garage installation, you will need to place the 10" (25.4 cm) pedestal at least 9" (22.9 cm) above the floor. You will need to place the 15.5" (39.4 cm) pedestal at least 3" (7.6 cm) above the floor.
Optional pedestal (15.5" [39.4 cm] model shown)
The pedestals are available in several colors. To order, call the dealer from whom you purchased your dryer or refer to the “Assistance or
Service” section.
Pedestal Height Color Part Number
10" (25.4 cm) White MHP1000SQ0 10" (25.4 cm) Black MHP1000SB0
15.5" (39.4 cm) White MHP1500SQ0
15.5" (39.4 cm) Black MHP1500SB0
15.5" (39.4 cm) Pacific Blue MHP1500SK0
Stack Kit
37" (93.98 cm)
Mobile home installations require special parts (listed following) that may be ordered by calling the dealer from whom you purchased your dryer. For further information, please refer to the “Assistance or Service” section.
Mobile Home Installation Kit. Ask for Part Number 346764.
Metal exhaust system hardware.
Are you planning to stack your washer and dryer? To do so, you will need to purchase a Stack Kit. To order, call the dealer from whom you purchased your dryer or refer to the “Assistance or Service” section. Ask for Part Number 8212640.
5
Location Requirements
WARNING
Explosion Hazard
Keep flammable materials and vapors, such as gasoline, away from dryer.
Place dryer at least 18 inches (46 cm) above the floor for a garage installation.
Failure to do so can result in death, explosion, or fire.
You will need
A location that allows for proper exhaust installation. A gas dryer must be exhausted to
the outdoors. See “Venting Requirements.”
A grounded electrical outlet located within 2 ft (61 cm) of either side of the dryer. See
“Electrical Requirements.”
A sturdy floor to support the total dryer weight of 200 lbs (90.7 kg). The combined weight
of a companion appliance should also be considered.
A level floor with a maximum slope of 1" (2.5 cm) under entire dryer. If slope is greater
than 1" (2.5 cm), install Extended Dryer Feet Kit, Part Number 279810. Clothes may not tumble properly, and automatic sensor cycles may not operate correctly if dryer is not level.
For a garage installation, you will need to place the dryer at least 18" (46 cm) above the
floor. If using a pedestal, you will need 18" (46 cm) to the bottom of the dryer.
Do not operate your dryer at temperatures below 45ºF (7ºC). At lower temperatures, the dryer might not shut off at the end of an automatic cycle. This can result in longer drying times.
The dryer must not be installed or stored in an area where it will be exposed to water and/or weather.
Check code requirements. Some codes limit, or do not permit, installation of the dryer in garages, closets, mobile homes or sleeping quarters. Contact your local building inspector.
NOTE: No other fuel-burning appliance can be installed in the same closet as a dryer.
Installation clearances
The location must be large enough to allow the dryer door to open fully.
Dryer Dimensions
51½"
(130.81 cm)
38"
(96.52 cm
)
*31½" (80 cm)
27"
(68.6 cm)
*Most installations require a minimum 5" (12.7 cm) clearance behind the dryer for the
exhaust vent with elbow. See “Venting Requirements.”
Installation spacing for recessed area or closet installation
The following spacing dimensions are recommended for this dryer. This dryer has been tested for spacing of 0" (0 cm) clearance on the sides and rear. Recommended spacing should be considered for the following reasons:
Additional spacing should be considered for ease of installation and servicing.
Additional clearances might be required for wall, door and floor moldings.
Additional spacing should be considered on all sides of the dryer to reduce noise transfer.
For closet installation, with a door, minimum ventilation openings in the top and bottom
of the door are required. Louvered doors with equivalent ventilation openings are acceptable.
Companion appliance spacing should also be considered.
Custom undercounter installation - Dryer only
0"
(0 cm)
38" min. (96.52 cm)
1"* (2.5 cm)
27" (68.6 cm)
1"* (2.5 cm)
*Required spacing
6
Closet installation - Dryer only
1"*
(2.5 cm)
14" max.* (35.6 cm)
18" min.* (45.72 cm)
31½"
(80 cm)
5"**
(12.7 cm)
2*
48 in.
(310 cm2)
2*
24 in.
(155 cm2)
A
A. Side view - closet or confined area B. Closet door with vents
*Required spacing **For side or bottom venting, 0" (0 cm) spacing is allowed.
Recessed or closet installation - Dryer on pedestal
B
(7.6 cm)
14" max.* (35.6 cm)
18" min.* (45.72 cm)
3"*
(7.6 cm)
3"*
Recommended installation spacing for cabinet installation
For cabinet installation, with a door, minimum ventilation openings in the top of the
cabinet are required.
7"* (17.8 cm)
*Required spacing
**For side or bottom venting, 0" (0 cm) spacing is allowed.
7"* (17.8 cm)
5"**
(12.7 cm)
31¹₂"
(80.0 cm)
1"* (2.5 cm)
1" 1"
(68.6 cm)
(2.5 cm)
27"
(2.5 cm)
9"* (22.9 cm)
1"
(2.5 cm)
27"
(68.6 cm)
1"
(2.5 cm)
1"*
(2.5 cm)
AB
A. Recessed area B. Side view - closet or confined area
*Required spacing **For side or bottom venting, 0" (0 cm) spacing is allowed.
31½"
(80 cm)
5"**
(12.7 cm)
7
Recommended installation spacing for recessed or closet installation, with stacked washer and dryer
Electrical Requirements
The dimensions shown are for the recommended spacing.
48 in.2 *
(310 cm2)
3"* (7.6 cm)
3"* (7.6 cm)
2
*
24 in.
(155 cm2)
*Required spacing
6"* (15.2 cm)
76"
(193 cm)
5"*
(12.7 cm)
1"
(2.5 cm)
27"
(68.6 cm)
*Required spacing
1"* (2.5 cm)
1"
(2.5 cm)
WARNING
Electrical Shock Hazard Plug into a grounded 3 prong outlet. Do not remove ground prong. Do not use an adapter. Do not use an extension cord. Failure to follow these instructions can result in death,
fire, or electrical shock.
120 Volt, 60 Hz., AC only, 15- or 20-amp fused electrical supply is required. A time-delay
fuse or circuit breaker is recommended. It is also recommended that a separate circuit serving only this dryer be provided.
GROUNDING INSTRUCTIONS
For a grounded, cord-connected dryer:
This dryer must be grounded. In the event of malfunction or breakdown, grounding will reduce the risk of electric shock by providing a path of least resistance for electric current. This dryer is equipped with a cord having an equipment­grounding conductor and a grounding plug. The plug must be plugged into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances.
Mobile home - Additional installation requirements
This dryer is suitable for mobile home installations. The installation must conform to the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280 (formerly the Federal Standard for Mobile Home Construction and Safety, Title 24, HUD Part 280) or Standard CAN/CSA-Z240 MH.
Mobile home installations require:
Metal exhaust system hardware, which is available for purchase from your dealer.
Mobile Home Installation Kit Part Number 346764. See “Tools and Parts” section for
information on ordering.
Special provisions must be made in mobile homes to introduce outside air into the dryer.
The opening (such as a nearby window) should be at least twice as large as the dryer exhaust opening.
8
WARNING: Improper connection of the equipment-
grounding conductor can result in a risk of electric shock. Check with a qualified electrician or service representative or personnel if you are in doubt as to whether the dryer is properly grounded. Do not modify the plug provided with the dryer: if it will not fit the outlet, have a proper outlet installed by a qualified electrician.
SAVE THESE INSTRUCTIONS
Gas Supply Requirements
WARNING
Explosion Hazard Use a new CSA International approved gas supply line. Install a shut-off valve. Securely tighten all gas connections. If connected to LP, have a qualified person make sure
gas pressure does not exceed 13" (33 cm) water column.
Examples of a qualified person include: licensed heating personnel,
authorized gas company personnel, and authorized service personnel.
Failure to do so can result in death, explosion, or fire.
Gas Type
Natural gas:
This dryer is equipped for use with Natural gas. It is design-certified by CSA International for LP (propane or butane) gases with appropriate conversion.
Your dryer must have the correct burner for the type of gas in your home. Burner
information is located on the rating plate in the door well of your dryer. If this information does not agree with the type of gas available, contact your dealer or call the phone numbers referenced in the “Assistance or Service” section.
LP gas conversion: Conversion must be made by a qualified technician.
No attempt shall be made to convert the appliance from the gas specified on the model/serial rating plate for use with a different gas without consulting your gas company.
If you are using Natural gas, do not use copper tubing.
Lengths over 20 ft (6.1 m) should use larger tubing and a different size adapter fitting.
If your dryer has been converted to use LP gas, ³⁄₈" LP compatible copper tubing can be
used. If the total length of the supply line is more than 20 ft (6.1 m), use larger pipe. NOTE: Pipe-joint compounds that resist the action of LP gas must be used. Do not use
TEFLON
Must include a shutoff valve:
®†
tape.
In the U.S.A.:
An individual manual shutoff valve must be installed within six (6) feet (1.8 m) of the dryer in accordance with the National Fuel Gas Code, ANSI Z223.1. The location should be easy to reach for opening and closing.
In Canada:
An individual manual shutoff valve must be installed in accordance with the B149.1, Natural Gas and Propane Installation Code. It is recommended that an individual manual shutoff valve be installed within six (6) feet (1.8 m) of the dryer. The location should be easy to reach for opening and closing.
A
C
B
A. ³⁄₈" flexible gas connector
B. ³⁄₈" pipe to flare adapter fitting
NPT minimum plugged tapping
C. ¹⁄₈" D. ½" NPT gas supply line
E. Gas shutoff valve
E
D
Gas supply connection requirements
Use an elbow and a ³⁄₈" flare x ³⁄₈" NPT adapter fitting between the flexible gas connector
and the dryer gas pipe, as needed to avoid kinking.
Use only pipe-joint compound. Do not use TEFLON
This dryer must be connected to the gas supply line with a listed flexible gas connector
®†
tape.
that complies with the standard for connectors for gas appliances, ANSI Z21.24 or CSA
6.10.
Gas supply line
Must include ¹⁄₈" NPT minimum plugged tapping accessible for test gauge connection,
immediately upstream of the gas connection to the dryer. See illustration.
¹⁄₂" IPS pipe is recommended.
³⁄₈" approved aluminum or copper tubing is acceptable for lengths under 20 ft (6.1 m) if
local codes and gas supplier permit.
Burner input requirements
Elevations above 10,000 ft (3,048 m):
When installed above 10,000 ft (3,048 m) a 4% reduction of the burner Btu rating shown
on the model/serial number plate is required for each 1,000 ft (305 m) increase in elevation.
®TEFLON is a registered trademark of E.I. Du Pont De Nemours and Company.
9
Gas supply pressure testing
The dryer must be disconnected from the gas supply piping system during pressure testing
at pressures greater than ½ psi.
Dryer gas pipe
The gas pipe that comes out through the rear of your dryer has a ³⁄₈" male pipe thread.
If using an existing vent system
Clean lint from the entire length of the system and make sure exhaust hood is not plugged
with lint.
Replace any plastic or metal foil vent with rigid or flexible heavy metal vent.
Review Vent system chart. Modify existing vent system if necessary to achieve the best
drying performance.
1½" (3.8 cm)
B
*6¼" (15.9 cm)
A
A. ½" NPT gas supply line
.
³⁄₈
" NPT dryer pipe
B
*NOTE: If the dryer is mounted on a pedestal, the gas pipe height must be an additional 10"
(25.4 cm) or 15.5" (39.4 cm) from the floor, depending on the pedestal model. For a garage installation, the gas pipe height must be an additional 18" (46 cm) from the floor.
Venting Requirements
WARNING
Fire Hazard Use a heavy metal vent. Do not use a plastic vent. Do not use a metal foil vent. Failure to follow these instructions can result in death
or fire.
If this is a new vent system
Vent materia l
Use a heavy metal vent. Do not use plastic or metal foil vent.
4" (10.2 cm) heavy metal exhaust vent and clamps must be used.
4"
10.2 cm
4" (10.2 cm) heavy metal exhaust vent
Vent products can be purchased from your dealer or by calling Maytag Services. For more information, see the “Assistance or Service” section.
Rigid metal vent
For best drying performance, rigid metal vents are recommended.
Rigid metal vent is recommended to avoid crushing and kinking.
Flexible metal vent
Flexible metal vents are acceptable only if accessible for cleaning.
Flexible metal vent must be fully extended and supported when the dryer is in its final
location.
Remove excess flexible metal vent to avoid sagging and kinking that may result in
reduced airflow and poor performance.
Do not install flexible metal vent in enclosed walls, ceilings or floors.
Elbows
45° elbows provide better airflow than 90° elbows.
WARNING: To reduce the risk of fire, this dryer MUST BE EXHAUSTED OUTDOORS.
IMPORTANT: Observe all governing codes and ordinances.
The dryer exhaust must not be connected into any gas vent, chimney, wall, ceiling or a concealed space of a building.
10
Good Better
Clamps
Use clamps to seal all joints.
Exhaust vent must not be connected or secured with screws or other fastening devices
that extend into the interior of the duct. Do not use duct tape.
Plan Vent System
Choose your exhaust installation type
Recommended exhaust installations
Typical installations vent the dryer from the rear of the dryer. Other installations are possible.
Clamp
Exhaust
Recommended hood styles are shown here.
B
A
4"
(10.2 cm)
4" (10.2 cm)
A. Louvered hood style B. Box hood style
The angled hood style (shown here) is acceptable.
4"
(10.2 cm)
2½"
(6.4 cm)
An exhaust hood should cap the vent to keep rodents and insects from entering the home.
Exhaust hood must be at least 12" (30.5 cm) from the ground or any object that may be in
the path of the exhaust (such as flowers, rocks or bushes, snow line, etc.).
Do not use an exhaust hood with a magnetic latch.
Improper venting can cause moisture and lint to collect indoors, which may result in:
Moisture damage to woodwork, furniture, paint, wallpaper, carpets, etc.
Housecleaning problems and health problems.
B
C
D
A
E F G
H
A. Dryer B. Elbow C. Wall
D. Exhaust hood
E. Clamps
F. Rigid metal or flexible metal vent G. Vent length necessary to connect elbows H. Exhaust outlet
Optional exhaust installations
This dryer can be converted to exhaust out the right side, left side or through the bottom. If you prefer, you may contact your local dealer to have the dryer converted.
WARNING
Fire Hazard
Cover unused exhaust holes with one of the following kits:
279818 (white) 279820 (black) 280102 (pacific blue) Contact your local dealer. Failure to follow these instructions can result in death,
fire, electrical shock, or serious injury.
11
Special provisions for mobile home installations
The exhaust vent must be securely fastened to a noncombustible portion of the mobile home structure and must not terminate beneath the mobile home. Terminate the exhaust vent outside.
A
A. Standard rear offset exhaust installation B. Left or right side exhaust installation C. Bottom exhaust installation
B
C
Alternate installations for close clearances
Venting systems come in many varieties. Select the type best for your installation. Two close­clearance installations are shown. Refer to the manufacturer’s instructions.
AB
A. Over-the-top installation (also available with one offset elbow) B. Periscope installation
NOTE: The following kits for close clearance alternate installations are available for purchase. Please see the “Assistance or Service” section to order.
Over-the-Top Installation:
Part Number 4396028
Periscope Installation (For use with dryer vent to wall vent mismatch):
Part Number 4396037 - 0" (0 cm) to 18" (45.72 cm) mismatch Part Number 4396011 - 18" (45.72 cm) to 29" (73.66 cm) mismatch Part Number 4396014 - 29" (73.66 cm) to 50" (127 cm) mismatch
Determine vent path
Select the route that will provide the straightest and most direct path outdoors.
Plan the installation to use the fewest number of elbows and turns.
When using elbows or making turns, allow as much room as possible.
Bend vent gradually to avoid kinking.
Use the fewest 90° turns possible.
Determine vent length and elbows needed for best drying performance
Use the following Vent system chart to determine type of vent material and hood
combinations acceptable to use. NOTE: Do not use vent runs longer than those specified in the Vent system chart. Exhaust
systems longer than those specified will:
Shorten the life of the dryer.
Reduce performance, resulting in longer drying times and increased energy usage.
The Vent system chart provides venting requirements that will help to achieve the best drying performance.
12
Vent system chart
B
NOTE: Side and bottom exhaust installations have a 90º turn inside the dryer. To determine maximum exhaust length, add one 90º turn to the chart.
Number of 90º turns or elbows
0 Rigid metal
1 Rigid metal
2 Rigid metal
3 Rigid metal
4 Rigid metal
Type of vent Box or louvered
hoods
Flexible metal
Flexible metal
Flexible metal
Flexible metal
Flexible metal
64 ft (20 m) 36 ft (11 m)
54 ft (16.5 m) 31 ft (9.4 m)
44 ft (13.4 m) 27 ft (8.2 m)
35 ft (10.7 m) 25 ft (7.6 m)
27 ft (8.2 m) 23 ft (7 m)
Angled hoods
58 ft (17.7 m) 28 ft (8.5 m)
48 ft (14.6 m) 23 ft (7 m)
38 ft (11.6 m) 19 ft (5.8 m)
29 ft (8.8 m) 17 ft (5.2 m)
21 ft (6.4 m) 15 ft (4.6 m)
Install Vent System
1. Install exhaust hood. Use caulking compound to seal exterior wall opening around
exhaust hood.
2. Connect vent to exhaust hood. Vent must fit inside exhaust hood. Secure vent to exhaust
hood with 4" (10.2 cm) clamp.
3. Run vent to dryer location. Use the straightest path possible. See “Determine vent path” in
“Plan Vent System.” Avoid 90º turns. Use clamps to seal all joints. Do not use duct tape, screws or other fastening devices that extend into the interior of the vent to secure vent.
3. Examine the leveling legs. Find the diamond marking.
4. Screw the legs into the leg holes by hand. Use a wrench to finish turning the legs until the
diamond marking is no longer visible.
5. Place a carton corner post from dryer packaging under each of the 2 dryer back corners.
Stand the dryer up. Slide the dryer on the corner posts until it is close to its final location. Leave enough room to connect the exhaust vent or gas line.
For mobile home use
Gas dryers must be securely fastened to the floor at the time of installation.
Install Leveling Legs
WARNING
Excessive Weight Hazard Use two or more people to move and install dryer. Failure to do so can result in back or other injury.
1. To protect the floor, use a large flat piece of cardboard from the dryer carton. Place
cardboard under the entire back edge of the dryer.
2. Firmly grasp the body of the dryer. Gently lay the dryer on the cardboard. See illustration.
Mobile home installations require a Mobile Home Installation Kit. For more information, please reference the service numbers in the “Assistance or Service” section.
Make Gas Connection
1. Remove the red cap from the gas pipe.
2. Using a wrench to tighten, connect the gas supply to the dryer. Use pipe-joint compound
on the threads of all non-flared male fittings. If flexible metal tubing is used, be sure there are no kinks.
A
A. Flared male fitting B. Non-flared male fitting
13
NOTE: For LP gas connections, you must use pipe-joint compound resistant to the action
D
C
of LP gas. Do not use TEFLON A combination of pipe fittings must be used to connect the dryer to the existing gas line.
Shown is a recommended connection. Your connection may be different, according to the supply line type, size and location.
®†
tape.
Level Dryer
Check the levelness of the dryer. Check levelness first side to side, then front to back.
A
B
A.
³⁄₈
" flexible gas connector
B.
³⁄₈
" dryer pipe
C.
³⁄₈
" to
³⁄₈
" pipe elbow
D.
³⁄₈
" pipe-to-flare adapter fitting
3. Open the shutoff valve in the supply line. The valve is open when the handle is parallel to
the gas pipe.
C
A
B
A. Closed valve B. Open valve
4. Test all connections by brushing on an approved noncorrosive leak-detection solution.
Bubbles will show a leak. Correct any leak found.
Connect Vent
1. Using a 4" (10.2 cm) clamp, connect vent to exhaust outlet in dryer. If connecting to
existing vent, make sure the vent is clean. The dryer vent must fit over the dryer exhaust outlet and inside the exhaust hood. Check that the vent is secured to exhaust hood with a 4" (10.2 cm) clamp.
2. Move dryer into its final location. Do not crush or kink vent.
3. (On gas models) Check that there are no kinks in the flexible gas line.
4. Once the exhaust vent connection is made, remove the corner posts and cardboard.
If the dryer is not level, prop up the dryer using a wood block. Use a wrench to adjust the legs up or down and check again for levelness.
Reverse Door Swing
You can change your door swing from a right-side opening to a left-side opening, if desired.
Remove the door
1. Open the dryer door. Remove the 4 screws that hold the door hinge on the front panel of
the dryer. Loosen, but do not remove, the screw with the top keyhole opening last (second from the top).
A
B
A. Dryer B. Do not remove. C. Dryer door
2. Lift and pull forward on the door so that the keyhole clears the screw head. Remove the
door.
®TEFLON is a registered trademark of E.I. Du Pont De Nemours and Company.
14
3. Lay the dryer door on a flat, protected surface with the inside door assembly facing up.
Remove the last screw from Step 1. Remove the 2 screws holding the handle to the door.
4. Remove the 6 screws to release the outer door assembly from the inner door assembly
(see illustration). It is important that you remove only the 6 indicated screws.
Reverse the hinge and hinge bracket
1. Place the inner door, screw head side up, on the work surface.
2. Remove the 4 screws that hold the hinge to the door.
3. Remove the 2 screws that hold the handle bracket to the door.
5. Lift the inner door assembly off of the outer door assembly. Unsnap the handle from the
outer door assembly, move it to the other side, and snap in. Set the outer door assembly aside.
4. Move hinge to the other side and reattach with the 4 screws removed in Step 2.
5. Move handle bracket to the other side and reattach with the 2 screws removed in Step 3.
6. Set the inner door assembly aside.
Reinstalling the door
1. Check for fingerprints on the glass. Clean if necessary.
2. Place the inner door assembly into the outer door assembly. Align the hinge in the
opening on the side. To fit correctly, the inside door assembly edge is completely inside the outside door assembly edge.
15
3. Reassemble the inner and outer door assemblies with the 6 screws.
B
C
4. Replace the 2 handle screws for the door handle of the door assembly.
5. Remove the plug strip or label. Style 1: Remove the plug strip.
Use a small flat-blade screwdriver to remove the plug strip in the door opening. Slide
the head of the screwdriver under the top portion of the plug strip, being certain not to scratch the dryer surface. Lift up. Repeat in the middle and at the bottom. Remove the plug strip in the door opening and insert in the opposite side.
A
A. Dryer door B. Dryer C. Insert this screw first.
7. Close the door and check that it latches securely.
Complete Installation
1. Check that all parts are now installed. If there is an extra part, go back through the steps to
see which step was skipped.
2. Check that you have all of your tools.
3. Check the dryer’s final location. Be sure the vent is not crushed or kinked.
4. Check that the dryer is level. See “Level Dryer.”
WARNING
Style 2: Remove the label.
Peel off the label located on the opposite side of the door opening covering the hinge
mounting holes. Apply the label over the original hinge holes.
6. Insert a screw in the second opening from the top of the hinge opening and partially tighten. Hang the door by placing the top hinge keyhole over the second screw head and tighten the screw. By putting this screw in first, the door will hang in place while you insert and tighten the remaining 4 screws.
16
Electrical Shock Hazard Plug into a grounded 3 prong outlet. Do not remove ground prong. Do not use an adapter. Do not use an extension cord. Failure to follow these instructions can result in death,
fire, or electrical shock.
5. Plug into a grounded 3 prong outlet. Turn on power.
6. Remove any protective film or tape remaining on the dryer.
7. Dispose of/recycle all packaging materials.
8. Read “Dryer Use.”
9. Wipe the dryer drum interior thoroughly with a damp cloth to remove any dust.
10. Select a Timed Dry heated cycle, and start the dryer. Do not select the Air Only
Temperature setting.
If the dryer will not start, check the following:
Controls are set in a running or “On” position.
Start button has been pushed firmly.
Dryer is plugged into a grounded 3 prong outlet.
Electrical supply is connected.
Household fuse is intact and tight, or circuit breaker has not tripped.
Dryer door is closed.
11. When the dryer has been running for 5 minutes, open the dryer door and feel for heat. If
you feel heat, cancel cycle and close door. If you do not feel heat, turn off the dryer and check that the gas supply line shutoff valve is open.
If the gas supply line shutoff valve is closed, open it, then repeat the 5-minute test as
outlined above.
If the gas supply line shutoff valve is open, contact a qualified technician.
DRYER USE
17
Loading...
+ 39 hidden pages