Maytag UXT5530AAS User Manual

E
Range Hood - 30" (76.2 cm) and 36" (91.4 cm)
PRODUCT MODEL NUMBERS
LOCATION REQUIREMENTS
UXT5530AA UXT5536AA
Because Whirlpool Corporation policy includes a continuous commitment to improve our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation Instructions packed with product. Specifications subject to change without notice.
Ref. W10274302B
10/22/09
CABINET OPENING DIMENSIONS
Electrical: A 120 volt, 60 Hz, AC only, 15- or 20-amp,
fused electrical circuit is required. A time-delay fuse or circuit breaker is also recommended. It is recommended that a separate circuit serving only this range hood be provided.
IMPORTANT: Observe all governing codes and ordinances.
It is the installer’s responsibility to comply with installation clearances specified on the model/serial rating plate. The model/serial rating plate is located inside the range hood on the left wall.
Range hood location should be away from strong draft areas, such as windows, doors and strong heating vents.
For Mobile Home Installations
The installation of this range hood must conform to the Manufactured Home Construction Safety Standards, Title 24 CFR, Part 328 (formerly the Federal Standard for Mobile Home Construction and Safety, title 24, HUD, Part 280) or when such standard is not applicable, the standard for Manufactured Home Installation 1982 (Manufactured Home Sites, Communities and Setups) ANSI A225.1/NFPA 501A*, or latest edition, or with local codes.
PRODUCT DIMENSIONS
VENTING REQUIREMENTS
Vent system can terminate either through the roof or wall. Use 3¹⁄₄" x 10" (8.3 x 25.4 cm) with a maximum vent length of 35 ft (10.7 m) or 6" (15.2 cm) or larger round vent with a maximum length of 50 ft (15.2 m) for vent system.
NOTE: Flexible vent is not recommended. Flexible vent creates back pressure and air turbulence that gently reduce performance.
Page 1 of 2
C
B
D
A
E
1³⁄₁₆"
(3.0 cm)
3" (7.6 cm) ­30" (76.2 cm) model 5³⁄₄" (14.6 cm) ­36" (91.4 cm) model
³⁄₄
"
19
(50.2 cm)
(30.5 cm)
2"
(5.1 cm)
(22.9 cm)
12"
7¹⁄₄"
(18.4 cm)
9"
29 ⁷⁄₈" (75.9 cm) - 30" (76.2 cm) model 35 ⁷⁄₈" (91.1 cm) - 36" (91.4 cm) model
⁵⁄₈"
(1.6 cm)
⁵⁄₈"
(1.6 cm)
Roof Venting Wall Venting
A
B
E
A
B
C
C
A. 18" (45.7 cm) min. clearance - upper cabinet to countertop B. 24" (61.0 cm) min. for electric cooking surfaces
27" (68.6 cm) min. for gas cooking surfaces 30" (76.2 cm) suggested max. - bottom of range hood to
cooking surface C. 30" (76.2 cm) or 36" (91.4 cm) min. cabinet opening width D. 13" (33.0 cm) cabinet depth E. 36" (91.4 cm) base cabinet height
D
A. 6" (15.2 cm) or larger round
vent or a 3¹⁄₄" x 10" (8.3 x
25.4 cm) rectangular vent through roof
B. Round vent: use 6" (15.2 cm)
or larger round damper (purchased separately)
(8.3 x 25.4 cm) to 6" (15.2 cm) or larger diameter transition piece (purchased separately)
D. 24" (61.0 cm) - 30" (76.2 cm)
above electric cooking surface 27" (68.6 cm) - 30" (76.2 cm) above gas cooking surface
E. Roof cap
D
A. 6" (15.2 cm) or larger round
vent or a 3¹⁄₄" x 10" (8.3 x
25.4 cm) rectangular vent through the wall
B. Round vent: use 3¹⁄₄" x 10" (8.3
x 25.4 cm) to 6" (15.2 cm) or larger diameter transition piece (purchased separately)
C. 3¹⁄₄" x 10" (8.3 x 25.4 cm)
through the wall
D. 24" (61.0 cm) - 30" (76.2 cm)
above electric cooking surface 27" (68.6 cm) - 30" (76.2 cm) above gas cooking surface
E. Wall cap
Because Whirlpool Corporation policy includes a continuous commitment to improve our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation Instructions packed with product. Specifications subject to change without notice.
Ref. W10274302B
10/22/09
Page 2 of 2
Calculating Vent System Length
To calculate the length of the system you need, add the equivalent feet (meters) for each vent piece used in the system.
6" (15.2 cm) or Larger Round Vent System Vent Piece Round
45° elbow 2.5 ft
(0.8 m)
90° elbow 5.0 ft
(1.5 m)
6" (15.2 cm) or larger 0.0 ft wall cap (0.0 m)
3¹⁄₄" x 10" (8.3 cm x 25.4 cm) 4.5 ft to 6" (15.2 cm) or larger (1.4 m)
3¹⁄₄" x 10" (8.3 cm x 25.4 cm) 5.0 ft to 6" (15.2 cm) or larger (1.5 m) 90° elbow
Example vent system
Maximum Recommended Length = 50 ft (15.2 m)
1 - 90° elbow = 5.0 ft (1.5 m) 1 - wall cap = 0.0 ft (0.0 m) 8 ft (2.4 m) straight = 8.0 ft (2.4 m) Length of 7" (17.8 cm) system = 13.0 ft (3.9 m)
3¹⁄₄" x 10" (8.3 cm x 25.4 cm) Vent System Vent Piece Round
3¹⁄₄" x 10" (8.3 cm x 25.4 cm) 5.0 ft 90° elbow (1.5 m)
3¹⁄₄" x 10" (8.3 cm x 25.4 cm) 12.0 ft flat elbow (3.7 m)
3¹⁄₄" x 10" (8.3 cm x 25.4 cm) 0.0 ft wall cap (0.0 m)
Example vent system
Maximum Recommended Length = 35 ft (10.7 m)
1 - 90° elbow = 5.0 ft (1.5 m) 8 ft (2.4 m) straight = 8.0 ft (2.4 m) 1 - wall cap = 0.0 ft (0.0 m) Length of 3¹⁄₄" x 10" (8.3 cm x 25.4 cm) = 13.0 ft (3.9 m)
system
Wall cap
3¹⁄₄" x 10"
(8.3 x 25.4 cm)
elbow
2 ft
(0.6 m)
6 ft (1.8 m)
90˚ elbow
2 ft (0.6 m)
6 ft (1.8 m)
Wall cap
Loading...