Range Hood – 30" (76.2 cm) and 36" (91.4 cm)
PRODUCT MODEL NUMBERS
UXT5230BD
UXT5236BD
Electrical: 120-volt, 60-Hz, AC-only, 15-amp. electrical supply. Use copper wire only. A time-delay fuse or circuit breaker and separate circuit is recommended.
PRODUCT DIMENSIONS
6⁹⁄₁₆" (16.7 cm) or 9⁹⁄₁₆" (24.4 cm)
9"
(22.9 cm)
1¹⁄₂"
(3.8 cm)
(2.5 cm)
18⁵⁄₈"
(47.3 cm)
1"
4¹⁵⁄₁₆"
(12.5 cm)
2"
(5.1 cm)
1"
(2.5 cm)
29¹⁵⁄₁₆" (76.0 cm) or 35¹⁵⁄₁₆" (91.0 cm)
INSTALLATION CLEARANCES
C
Venting Methods
NOTES:
Flexible vent is not recommended. Flexible vent creates both back pressure and air turbulence that greatly reduce performance.
The vent system is optional for this model. Vent system can terminate either through the roof or wall. Use
3¼" x 10" (8.3 x 25.4 cm) rectangular with a maximum vent length of 35 ft (10.7 m) or 7" (17.8 cm) or larger round vent with a maximum length of 50 ft (15.2 m) for vent system.
Top Venting Wall Venting
B
A
A
A. 7" (17.8 cm) round vent through roof (purchased separately). 3¼" x 10" (8.3 x 25.4 cm) rectangular vent through the roof (purchased separately). B. Roof cap with damper (purchased separately)
A. 7" (17.8 cm) round vent out the top and through the wall (purchased separately). 3¼" x 10" (8.3 x 25.4 cm) rectangular vent through the wall or out the top (purchased separately). B. Wall cap with damper (purchased separately)
B
A
D
B
E
A. 18" (45.7 cm) minimum distance from electric cooking surface. 24" (61.0 cm) minimum distance from gas cooking surface. 30" (76.2 cm) suggested maximum above the cooking surface. B. 18" (45.7 cm) minimum clearance - upper cabinet to countertop. C. 30" (76.2 cm) minimum cabinet opening width for 30" (76.2 cm) models and 36" (91.4 cm) minimum cabinet width for 36" (91.4 cm) models. D. 12" (30.5 cm) cabinet depth. E. 36" (91.4 cm) base cabinet height.
Example vent system
90˚ elbow
2 ft (0.6 m)
6 ft (1.8 m)
Wall cap
1 - 90° elbow = 5.0 ft (1.5 m)
1 - wall cap = 0.0 ft (0.0 m)
8 ft (2.4 m) straight = 8.0 ft (2.4 m)
System length = 13.0 ft (3.9 m
Maximum Recommended Length)
7” (17.8 cm) Round Vent = 50 ft (15.2 m)
3¼" x 10" (8.3 x 25.4 cm) = 35 ft (10.7 m) Rectangular Vent
Because Whirlpool Corporation policy includes a continuous commitment to improve our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation Instructions packed with product. Specifications subject to change without notice.
Page 1 of 2
W10646405-D-UN
04/2015
Calculating Vent System Length
To calculate the length of the system you need, add the equivalent feet (meters) for each vent piece used in the system.
Vent System
Vent Piece
45° elbow 2.5 ft
(0.8 m)
90° elbow 5.0 ft
(1.5 m)
3¼" x 10" (8.3 cm x
25.4 cm) flat elbow
12.0 ft (3.7 m)
7" (17.8 cm) wall cap 0.0 ft
(0.0 m)
3¼" x 10" (8.3 cm x
25.4 cm) to 7" (17.8 cm)
3¼" x 10" (8.3 cm x
25.4 cm) to 7" (17.8 cm)
4.5 ft (1.4 m)
5.0 ft (1.5 m)
90° elbow
Because Whirlpool Corporation policy includes a continuous commitment to improve our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation Instructions packed with product. Specifications subject to change without notice.
Page 2 of 2
W10646405-D-UN
04/2015