ATTENTION INSTALLING PERSONNEL
RECOGNIZE THIS SYMBOL AS A SAFETY PRECAUTION.
As a professional installer you have an obligation to know the product better than the customer. This
includes all safety precautions and related items.
Prior to actual installation, thoroughly familiarize yourself with this Instruction Manual. Pay special
attention to all safety warnings. Often during installation or repair it is possible to place yourself in a
position which is more hazardous than when the unit is in operation.
Remember, it is your responsibility to install the product safely and to know it well enough to be able to
instruct a customer in its safe use.
Safety is a matter of common sense...a matter of thinking before acting. Most dealers have a list of
specific good safety practices...follow them.
The precautions listed in this Installation Manual are intended as supplemental to existing practices.
However, if there is a direct conflict between existing practices and the content of this manual, the
precautions listed here take precedence.
2001-2004 Goodman Company, L.P.
Effective: August 2004
IMPORTANT NOTE TO THE OWNER
This equipment is to be serviced by professionally trained
personnel only. If this equipment is improperly installed,
adjusted or altered by an unqualified person, a safety
hazard may result.
IMPORTANT NOTE TO THE SERVICER
Read this manual and familiarize yourself with the specific
items which must be adhered to before attempting to
service this unit. The precautions listed in this manual
should not supersede existing practices but should be
considered as supplemental information.
Unit Features
This unit has an exhaust air option which allows you to bring
outdoor air into the room. To bring air in from outside, snap
in the supplied perforated exhaust air plug (Figure 1) in the
location shown in Figure 2. To use only indoor air, snap in
the solid exhaust air plug.
NOTE: The exhaust air option (perforated plate installed)
can be used in any operation mode.
Transportation Damage
All units are securely packed in shipping containers approved by the National Safe Transit Association. The
carton should be checked upon arrival for external damage.
If damage is found, immediately make a written request for
inspection by the carrier’s agent.
In the event of damage:
1. Note on the delivery receipt any visible damage to
shipment or container.
2. Notify carrier promptly and request an inspection.
3. File the claim with the following supporting documents
within the six month statute of limitations.
a. Original Bill of Lading, certified copy, or indemnity
bond.
b. Original paid freight bill or indemnity.
c. Original invoice or certified copy, showing trade and
other discounts or reductions.
d. Copy of the inspection report issued by carrier’s
representative at the time damage is reported to the
carrier.
The carrier is responsible for making prompt inspection of
damage and for a thorough investigation of each claim. The
distributor or manufacturer will not accept claims from
dealers for transportation damage.
Figure 1
EXHAUST AIR PLUG
Figure 2
Unpacking The Unit
1. Cut the carton banding and open the carton.
2. Remove the literature, hardware pack, upper styrofoam
shipping blocks, and styrofoam corner posts.
3. Remove the front assembly.
4. Cut the carton around the perimeter of the box 2” from
the bottom and discard the top.
5. Lift the unit from the remaining carton.
6. Dispose of the cardboard and styrofoam at an approved Recycle Center. Check all contents for damaged or missing parts. In case of concealed damage,
notify the carrier as soon as possible—preferably within
5 days. Refer to step 3 of the Transportation Damage
section if damage or missing parts are noted.
Parts Supplied
SizeDescriptionQuantity
1/2” x 1” x 14” Foam Gasket2
1/2” x 1/2”Foam Gasket (54”)1
Sleeve Clip2
#8 x 3/8”Blunt Point Sheet Metal Screw2
Perforated (Fresh Air) Plug1
Solid (Fresh Air) Plug1
Plastic Knob2
#8 x 3/8”Washer Head Sheet Metal Screw4
2
Unit Accessories
This unit is designed for through-the-wall installation in new
or existing buildings. To complete the installation in an
existing wall sleeve, a TWKG rear louver panel kit, a
TWEAK or TWFAK adapter kit is required.
If the sleeve is a GE wall sleeve, use the TWKG rear louver
panel kit. If the sleeve is an Emerson wall sleeve, use the
TWEAK adapter kit, If the sleeve is a Fedders or Freidrich
wall sleeve, use the TWFAK adapter kit.
The chassis and wall sleeve are shipped separate.
Operating Instructions
Check the data specification plate and ensure the proper
voltage and current rating for the type of power plug on the
unit is available. DO NOT REMOVE THE GROUNDING
PRONG FROM THE POWER CORD. See Figure 3 for the
types of acceptable plugs. Do not use an extension cord for
the installation of this product. Refer to the data specification plate for electrical requirements.
110V230V230V
15 amp15 amp20 amp
FOAM
Figure 4
SLEEVE INSTALLATION
In order for condensate water to drain properly inside the
unit, the sleeve must be installed properly:
•Level from right to left.
•A slight downward pitch from the indoor side to the
outdoor side as shown in Figure 5.
Refer to the Installation Instructions supplied with the wall
sleeve for a complete description of the installation procedure.
OutsideInside
Level
Figure 3
LCDI or AFCI Power Cords
Underwriters Laboratories (UL) and the National Electric
Code (NEC) now require power cords that sense current
leakage and can open the electrical circuit to the unit. In the
event, the unit does not operate, check the reset button
located on or near the head of the power cord as part of the
normal troubleshooting procedure.
WARNING
To prevent property damage, personal
injury or death, do not remove grounding
prong from plug. Follow all operating
instructions.
Installation Instructions
To ensure that the unit operates safely and efficiently, it
must be installed, operated, and maintained according to
these installation and operating instructions and all local
codes and ordinances, or, in their absence, with the latest
edition of the National Electrical Code. The proper installation of this unit is described in the following sections.
Following the steps in the order presented should ensure
proper installation.
NOTE: Attach the supplied 1/2” x 1” x 14” foam prior to
installation of unit. Remove adhesive backing strip and
place the foam on unit as shown in Figure 4.
Wall
Sleeve
Outside
Wall
1/4 Bubble
Tilt To
Outside
Figure 5
REAR LOUVER PANEL
A TWKG rear louver panel kit is required for unit installation
into an existing GE 26” wall sleeve. A TWEAK or TWFAK
adapter kit is required for unit installation into an existing 27”
wall sleeve. The rear louver panel directs air flow for proper
unit operation and protects the outdoor coil. The panel must
be installed before installing the chassis. These kits are not
supplied with the unit. Refer to the Installation Instructions
supplied with the rear louver panel kit for a complete
description of the installation procedure.
NOTE: If using a GE wall sleeve, ensure that the rear
enclosure panel is removed before installing the TWKG
panel.
3